Preferred Language
Articles
/
ijs-8095
Algorithm Development for Full Gaps of Landsat 7 Images
...Show More Authors

      Landsat7 of Enhanced thematic mapper plus (ETM+) was launched on April 15,  1999. Four years later, images start degrading due to the scan line corrector (SLC). SLC is a malfunction that results in pixel gaps in images captured by the sensor of Landsat7. The pixel gap regions extend from about one pixel near the image center and reach up to about 14 pixels in width near the image edge. The shape of this loss is like a zigzag line; however, there are different studies about repairing these gaps. The challenge of all studies depends on retrieving inhomogeneous areas because the homogenous area can be retrieved quickly depending on the surrounding area. This research focuses on filling these gaps by utilizing pixels around them gaps. Pixels from different satellites with the same resolution at the approximate equal date and exact location would be utilized.

Mean and standard deviation were used in gap pixel predicting. For complete pixels gap predicting, an image registration should be applied for predicted a good result—image registration comprised of geometric and radiometric registration. Translation and rotation was the main effect of geometric registration, while pixel tone was mainly related to radiometric registration. Two images of Landsat8 (before and after) with nearly the date of Landsat 7 were used. The fidelity criteria (mean square error and mean absolute error) were utilized to evaluate the results. The results showed a good prediction of the gap pixels in the Landsat 7 image, considering the geometric and radiometric parts.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Experimental and Theoretical Determination of Settlement of Shallow Footing on Liquefiable Soil
...Show More Authors

A high settlement may take place in shallow footing when resting on liquefiable soil if subjected to earthquake loading. In this study, a series of shaking table tests were carried out for shallow footing resting on sand soil. The input motion is three earthquake loadings (0.05g, 0.1g, and 0.2g). The study includes a reviewing of theoretical equations (available in literatures), which estimating settlement of footings due to earthquake loading, calibration, and verification of these equations with data from the shaking table test for improved soil by grouting and unimproved soil. It is worthy to note that the grouting materials considered in this study are the Bentonite and CKD slurries. A modification to the seismic set

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Influence of doping concentration on the main parameters of CdSe:Cu photoconductor detector
...Show More Authors

The photonconductor detectors CdSe:Cu was fabricated as a thin film of (1 μm) in thickness using vacuum evaporation technique. doping with copper was made using vacuum annealing at 350oC under argon atmosphere . The spectral responsivity and spectral detectivity of the detector were determined as a function of incident wavelength on the sample. A remarkable improvement in performance was absorbed for the specimen, which doping with (1-5 wt%) Cu.
The spectral response increases with increasing of wavelength for incident radiation to maximum value, after that , it reduced sharply . There is a shifting for peak responsivity indirect of higher wavelength. The detectivity was increased with doping but its decreased as the concentration in

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 29 2021
Journal Name
Iraqi Journal Of Science
Assessment of water Quality Index of Gr oundwater in Al-Khadhimiya city
...Show More Authors

The present study deals with the assessment of water Quality Index to theAl-
Khadhimiya Groundwater city, by collection groundwater from 13wells during four
seasons, subjecting the samples to a comprehensive physicochemical analysis. The
13 parameters have been considered: pH, total hardness, calcium, magnesium,
turbidity, nitrate, electrical conductivity, total dissolved solid, Sulfate, Chloride,
zinc, manganic, and iron, that are used for calculating the WQI. From the result
shown, the most groundwater quality lies in Unfit for human drinking purpose. The
wells (1 and 11) and wells (3 and 10) were a bad water quality for drinking purpose
since they lie in poor and in very poor respectively according to the WQI.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 29 2020
Journal Name
Iraqi Journal Of Science
ANALYSIS of INTERFERENCE PATTERN of the FIBER INTERFEROMETER as a MOTION SENCOR
...Show More Authors

The production and analysis of an optimal interference pattern for the optical fiber interferometer of a 193.1THz continuous laser source was simulated by comparing the spectral spectroscopy of the two arms of interferometer to be used as a heterodyne detection in sensing the body range, speed, and direction of movement by delaying the time between the arms.

     The study showed that the fringe pattern can be sensed a range by the free spectral range FSR and the velocity by the fringe separation FS and the direction by the fringe spatial frequency FSF.

View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effect of Temperature on the Stability and Release Profile of Ibuprofen Microcapsules
...Show More Authors

The stability and releasing profile of 2:1 core: wall ratio ibuprofen microcapsules prepared by aqueous coacervation (gelatin and acacia polymers coat) and an organic coacervation methods (ethyl cellulose and sodium alginate polymers coat) in weight equivalent to 300mg drug, were studied using different storage temperatures 40°C, 50°C ,60°C and refrigerator temperature 4°C in an opened and closed container for three months (releasing profile) and four months (stability study).It was found that, these ibuprofen microcapsules were stable with expiration dates of 4.1 and 3.1 years for aqueous and an organic method respectively.Aqueous prepared ibuprofen microcapsules were found more stable than those microcapsules prepared by or

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 09 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Improvement of the Solubility and Dissolution Characteristics of Risperidone via Nanosuspension Formulations
...Show More Authors

Risperidone is an atypical antipsychotic drug that is used for treating schizophrenia, bipolar mania, and autism. Risperidone rebalances dopamine and serotonin to improve thinking, mood, and behavior by working on dopamine and serotonin α2receptor antagonism. Risperidone has poor solubility and high permeability through the intestine, so it belongs to Biopharmaceutical Classification System (BCS) class II exhibits poor oral biopharmaceutical properties.

 The aim of the present work was to improve solubility and dissolution of Risperidone by preparing nanosuspension using different stabilizers and different solvents‎ in a method known as solvent-antisolvent precipitation method.  Twenty-eight formulas were prepared

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Synthesis of Sn1-xMnxO2Nanoparticles and study of the structural and optical properties
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Feb 26 2021
Journal Name
Iraqi Journal Of Science
Antibacterial Susceptibility of Clinical Isolates of Klebsiella pneumoniae in Nigeria to Carbapenems
...Show More Authors

The emergent bacterial resistance to antibiotics, most especially Carbapenems, has become a common phenomenon. The aim of the recent study was the observation and evaluation of the antibacterial susceptibility of Klebsiella pneumoniae in clinical specimens to different Carbapenems. One hundred isolates of K. pneumoniae isolated from different clinical sites, such as leg, caesarean section (CS), head, buttock, breast, thigh, and arm were tested. Using disc diffusion method, the isolates were tested for susceptibility to different antibiotics including Tobramycin, Ciprofloxacin, Aztreonam, Colistin sulphate, Ceftriaxone, Cefepime, Cefoxitin, Ceftazidime, Ertapenem, Meropenem, and Imipenem. The results were interpreted acc

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Study of Some Structural Properties of Porous Silicon Preparing by Photochemical Etching
...Show More Authors

Porous Silicon (PSi) has been produced in this work by using Photochemical (PC) etching process by using a hydrofluoric acid (HF) solution. The irradiation has been achieved using quartz- tungsten halogen lamp. The influence of various irradiation times on the properties of PSi اmaterial such as layer thickness, etching rate and porosity was investigated in this work too.
The XRD has been studied to determine the crystal structure and the crystalline size of PSi material

View Publication Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF