Thirty-two soil samples were collected from the study area in October 2020 for geochemical and pollutants investigation of Shwan Sub-basin soil. All soil samples were analysed for different geochemical analyses. The analysis results revealed that the pH values in soil samples ranged from 7.12 to 7.56 with a mean of 7.327. According to the pH values detected in the soil samples, the soil is classified as neutral soil. The electrical conductivity ranged from 0.92 mmhos/cm to 7.8 mmhos/cm with a mean of 1.53 mmhos/cm. Thus, according to the detected electrical conductivity values, the soil was classified as non-saline to slightly saline. The organic matter ranged from 1.14% to 1.45% with a mean value of 1.326 %, while total organic carbon ranged from 0.66 % to 0.84 % with a mean value of 0.769 % which indicated the soil was characterized by low organic content. The results of the geochemical analysis revealed that the major and minor element mean concentrations were in the order Si> Ca> Al> Fe> Mg > K> Ti> Na> P> Mn> S> Cl> N. The average concentrations of trace elements in soil samples followed the decreasing order Sr > Cr> Ba> Zr> Ni> V> Zn> Ta> Rb> Cu> Nb> Y> Pb> Co> Ga> Mo> As> Th> Br> Sn> I. Furthermore, the comparison between heavy metal concentrations in the soil of the study area and metal concentrations in the world soil limit and Indirect Geochemical Background revealed an increase in metal concentrations of Cr, Ni, Zn, Co, As, Mo and Ta. Multivariate statistical analyses, such as Principal Component Analysis and Agglomerative Hierarchal Cluster Analysis, identified the potential sources of pollutants in the soil. Most metals are from natural sources and some of them are from anthropogenic sources mostly from agricultural activities mainly fertilizers use and the waste of animals breeding on farms. Besides industrial activities such as deposits of pollutants from emissions of petroleum refineries located inside or close to the study area. In addition, building blocks and paint factories.
Quantum dots of CdSe, CdS and ZnS QDs were prepared by chemical reaction and used to fabricate organic quantum dot hybrid junction device. QD-LEDs were fabricated using layers of ITO/TPD: PMMA/CdSe/Alq3, ITO/TPD: PMMA/CdS/Alq3 and ITO/TPD: PMMA/ZnS/Alq3 devices which prepared by phase segregation method. The hybrid white light emitting devices consists, of three-layers deposited successively on the ITO glass substrate; the first layer was of N, N’-bis (3-methylphenyl)-N, N’-bis (phenyl) benzidine (TPD) polymer mixed with polymethyl methacrylate (PMMA) polymers. The second layer was QDs while the third layer was tris (8-hydroxyquinoline) aluminium (Alq3
... Show MoreWe report on using a CO2 (10.6 µm) laser to debond the lithium disilicate veneers. Sixty-four sound human premolar teeth and 64 veneer specimens were used in the study. The zigzag movement via CO2 laser handpiece along with an air-cooled jet to prevent temperature elevation above the necrosis temperature limit (5.5 C°) was applied. The optimal deboning irradiation time was super-fast, at about 5 seconds at 3 Watt CO2 laser power. It is 20 times less than any previously published work for veneers debonding. The enamel beneath the debonded veneers has been assessed by atomic force microscopy (AFM) and shear stress technique as criteria for the easiness of debonding. The
... Show MoreRemote sensing is a source of up-to-date information. The present study relied on various approaches for gathering information, including descriptive, quantitative and quantitative analytical processes. Particularly, we conducted the analysis of the satellite data ETM + of the satellite Landsat7 and the digital models of Digital Elevation Model of SRTM using ArcGIS9.2. The model depends on primary mathematical equations and constitutes an essential base for GIS applications that rely on data, computer, and software, performing the processes of data entry, analysis and processing. This paper deals with the geomorphological characteristics of a selected study area in Kirkuk province. The cha
... Show MoreThe research aims at showing the effectiveness of the existing deposit facilities in the liquidity of the Iraqi banking system for the period 2010/2017. The problem of research indicates that the Iraqi banking system enjoys high liquidity levels exceeding the standard rate set by the Central Bank of Iraq amounting to 30% For an appropriate level of liquidity remains a major challenge to the management of the bank because it is a trade-off between profitability and liquidity, and also indicates the existence of funds disabled and not available for credit and investment opportunities, and based on the research hypothesis:
The existence of a significant effect of the deposit facilities existing in the liquidity of the Iraqi banking
... Show MoreAir pollution evaluation of the operational processes in the East Baghdad oil field was carried out. The analysis was carried out by ICP-MS technique. Total Suspended Particles (TSP) air load was higher than Iraqi Standards and world international allowable limits of World Health Organization. The mean concentrations of gases carbon monoxide, carbon dioxide, sulfur dioxide, in the air were within national and world standards, while the mean concentration of nitrogen dioxide was higher than standard limits. The air of the study area is considered a good quality for CO, CO2 and NO2 with no health effect, while it is hazardous for TSP that have serious risk for people with respiratory disease. The mean concentrations of Cd, Cr, Cu and
... Show MoreThis study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in th
... Show More