Determination of vitamin B6 (pyridoxine hydrochloride) was described using high performance liquid chromatographic method. The analysis was achieved by cosmos IL 5C18-MS-II column (250 mm x 4.6 mm i. d., 5µm particle size) at room temperature. The mobile phase used was Acetonitrile, buffer solution (Citric acid, Na2HPO4 pH4) buffer solution in the ratio (70:30) (V: V). the flow rate was set to 1.25 mL.min-1 and the retention time 1.82 min with UV-detection at 282 nm. Beer's law was obeyed over the concentration range 10-1250 µg.mL-1. The method was accurate (relative error % less than 0.05%), precise (RSD better than ±1.05%), average recovery 100.05%, with a limit of detection and quantification of 2.2μg.ml−1, and 7.34μg.mL−1 respectively. The proposed method was successfully applied to determine the pyridoxine hydrochloride in pharmaceutical preparations in both forms of tablet and injection
advancing age. The risk of cardiovascular disease in adults is lowest with systolic BP <120 mm Hg and diastolic BP < 80 mm Hg and increases progressively with higher systolic and diastolic blood pressures. Acupuncture (from the Latin word acus, “needle”, and pungere, meaning “prick”) is a technique in which the practitioner inserts fine needles into specific points on the patient’s body. Accupuncture could be used as a nonpharmacological way of controlling high readings of blood pressure among cases with essential hypertension. This study aimed to investigate the effects of acupuncture on essential hypertension.
Patients and Methods: 51 hypertensive patients of both genders and 30 normotensive control subjects were inv
In this study the isomerization of desulfuerized light Iraqi petroleum naphtha (Al-Dura Refinery) with boiling point range of 37 to 124 °C , 80.5 API specific gravity and 68.2 octane number has been investigated. Two types of catalysts were prepared (Pt/HX and Pt/SrX) by impregnation of 0.8 wt% Pt on l 3X-zeolite. The catalyst activity and selectivity toward isomerization, and catalyst deactivation were investigated.
The isomerization unit consisted of a vertical tubular stainless steel reactor of 2 cm internal diameter, 3 cm external diameter and 68 cm height. The operating pressure was atmospheric for all experimental runs. The liquid flow of lightnaphtha was 0.4 Uh, and the catalyst weight was 50 gm, H/
... Show MoreThe objective of this study was to establish an accurate, precise, sensitive, simple, fast and reliable method for the determination of ciprofloxacin hydrochloride in pure or in pharmaceutical dosage forms using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. The method is based upon the fluorescence fluorescein sodium salt and its quenching by ciprofloxacin hydrochloride in aqueous medium. The solutions of standard and the sample were prepared in distilled water. The calibration graph was linear in the concentration range of using (10 - 100) mMol.L-1 ciprofloxacin hydrochloride (r= 0.9891) with relative standard deviation (RSD%) for 3 mMol.L-1 ciprofloxacin HCl solution is
... Show MoreThe reality of the field of construction projects in Iraq refers to needing for the development of performance in order to improve quality and reduce defects and errors and to control the time and cost, so there is needing for the application of effective methods in this area, one of the methods that can be applied in this area is the manner of Six Sigma. This research aims to enhance the performance and quality improvement for the construction projects by improving performance in the work of the implementation of the concrete structure depending on the Six Sigma methodology, and for the purpose of achieving the aim of the research, the researcher firstly depends on the theoretical study that include the concepts of qual
... Show MoreAnalysis and determination of some of the elastic moduli and other geotechnical parameters in the campus of the University of Baghdad performed by using New Sonic Viewer in the field to measure (Vp) and (Vs) velocities as well as the density of the upper soil inside the campus. Seventeen profiles were selected each of (10) m. length distributed randomly inside the university campus to evaluate the top soil properties in addition to the soil profile.
The ultrasonic waves showed two layers of the soil with different velocities of
(Vp) and (Vs). The velocities of p-wave of the first layer ranged from (288-642) m/sec. On other hand the velocities of shear wave (Vs) in the same layer ranged from (88-193) m/sec. In the second layer the v
Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show MoreThe concentration of elements were analyzed of twelve cultivation medium (Peat moss, Perlite and Hermon) selected from Iraqi markets using X-ray fluorescence techniques. The analytical results show that the cultivation medium contained high concentration of (Na, Al, Si, S, K, Ca, Fe) and low concentration of (Mg, P, Cl, Ti, V, Cr, Mn, Co, Ni, Cu, Zn). The samples also contained trace concentration of (Ge, As, Se, Br, Sr, Y, Mo, Cd, I, Hg, Pb, U). The results were compared using atomic absorption spectrophotometric technique for measuring the concentration of (K, Ca, Cu, Mn, Zn, Pb).
The Results showed that there is significant difference in the concentration of each element in most of the samples. The concentrations of elements a
... Show MoreA newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma
... Show More