One of the health issues that a coronavirus can induce is blood clotting. Coronavirus can be prevented in a number of ways. Vaccination is one of the critical methods for preventing illness or lessening its impact. This study seeks to estimate a few blood coagulation variables. 147 samples were collected from the Baghdad Governorate in the autumn of 2021. The samples were split into three groups: COVID-19 patients, healthy individuals before and after receiving the (Pfizer-BioNTech) vaccine, and healthy individuals only. Prothrombin Time (PT), Partial Thromboplastin Time (PTT), Protein C (PTN-C), Protein S (PTN-S), and International Normalized Ratio (INR) for 49 samples were measured and computed for each group. The results have shown that the PTN-C and PTN-S concentrations were significantly decreased in the COVID-19 patients compared to unvaccinated healthy individuals. While INR of COVID-19 patients showed a highly significant increase when compared with unvaccinated healthy individuals. At the same time, there was no significant difference for each PT and PTT between these studied groups. The parameters exhibit identical findings when COVID-19 patients are compared to those who have had vaccinations, with the exception of PT, which reveals a highly significant rise in COVID-19 patients when compared to those who have received vaccinations. Conclusion: COVID-19 causes blood clots and may be recognized by a decrease in PTN-C and PTN-S content.
Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95
... Show Moreالمستودع الرقمي العراقي. مركز المعلومات الرقمية التابع لمكتبة العتبة العباسية المقدسة
This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use
... Show MoreThe existing investigation explains the consequence of irradiation of violet laser on the structure properties of MawsoniteCu6Fe2SnS8 [CFTS] thin films. The film was equipped by the utilization of semi-computerized spray pyrolysis technique (SCSPT), it is the first time that this technique is used in the preparation and irradiation using a laser. when the received films were processed by continuous red laser (700 nm) with power (>1000mW) for different laser irradiation time using different number of times a laser scan (0, 6, 9, 12, 15 and 18 times) with total irradiation time (0,30,45,60,75,90 min) respectively at room temperature.. The XRD diffraction gave polycrysta
... Show MoreIn this article four samples of HgBa2Ca2Cu2.4Ag0.6O8+δ were prepared and irradiated with different doses of gamma radiation 6, 8 and 10 Mrad. The effects of gamma irradiation on structure of HgBa2Ca2Cu2.4Ag0.6O8+δ samples were characterized using X-ray diffraction. It was concluded that there effect on structure by gamma irradiation. Scherrer, crystallization, and Williamson equations were applied based on the X-ray diffraction diagram and for all gamma doses, to calculate crystal size, strain, and degree of crystallinity. I
... Show More