The study area intendes for agricultural investment and establishment stations of water pumping for human use to the nearby areas, southwest of Samawah city. Twelve Two-Dimension (2-D) survey points were performed by using Wenner-Schlumberger array configuration to take the measurements. The inverse models of two survey point appear the effect of the saline groundwater that raises from Rus Formation, which caused a significant reduction in resistivity of the groundwater-bearing zone within middle Dammam Formation along the fault plane.
The groundwater evaluation has been carried out in Khanaqin area in Diyala governorate to the east of Iraq. The analyzed hydrochemical parameters such as pH, electrical conductivity, total dissolved solids as well as cations and anions are used to describe groundwater quality and its suitability for different purposes. The study area covers (1920) km2. According to hydrogeological investigation (43) water points were inventoried and water levels in wells were measured. (34) Wells were sampled during 2013-2014 during water surplus and water deficit periods. The studied area is divided groundwater aquifers into two main units, the unconfined and confined aquifers. The values of pH, electrical conductivity (EC) and total dissolve
... Show MoreThis study aims to determine the reasons for the increase in the frequency of sand and dust storms in the Middle East and to identify their sources and mitigate them. A set of climatic data from 60 years (1960–2022) was analyzed. Sand storms in Iraq are a silty sand mature arkose composed of 72.7% sand, 25.1% silt, and 2.19% clay; the clay fraction in dust storms constitutes 70%, with a small amount of silt (20.6%) and sand (9.4%). Dust and sand storms (%) are composed of quartz (49.2, 67.1), feldspar (4.9, 20.9), calcite (38, 5), gypsum (4.8, 0.4), dolomite (0.8, 1.0), and heavy minerals (3.2, 6.6). Increasing temperatures in Iraq, by an average of 2 °C for sixty years, have contributed to an increase in the number of dust storm
... Show MoreThis study deals with the petrology of Injana Formation (Upper Miocene) at
Zawita, Amadia and Zakho areas. The sandstone of Injana Formation is of two
typesnamely, litharenite and feldspathiclitharenite. The rock fragments of Injana
Formation are mostly sedimentary and hence the sandstones are classified as
sedarenite and more specifically chertarenite owing to the predominance of chert
rock fragments. The sandstone is mineralogicallysubmature rangingfrom
mechanically and chemically stable tounstable. The petrographic studies reveal
nearness of source area with arid to semi-arid climate. The source rocks are
sedimentary, low- to medium-grade metamorphic and basic volcanic rocks. They are
mostly supplied from th
The linguistic meaning of the verse in the Arabic dictionaries applies very much to the reality of rent and its effect. This is true of economic growth as a continuous increase in real per capita income in addition to the same thing. Therefore, development does not necessarily achieve a comprehensive and structural increase of the various economic sectors. As the rent came in the sense of a terrible land open Maim any fertilized. And the camel is a ma'aya and a ra'i: that is, it goes in the pasture and returns itself. This is similar to the extraction of oil after it is ready for investment and earn its revenue as soon as it exists or is extracted by external parties. If the rent is first linked to agriculture, especially the fertile lan
... Show MoreRates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respective
... Show MoreRates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respect
... Show MoreThe effect of time (or corrosion products formation) on corrosion rates of carbon steel pipe in aerated 0.1N NaCl
solution under turbulent flow conditions is investigated. Tests are conducted using electrochemical polarization
technique by determining the limiting current density of oxygen reduction in Reynolds number range of 15000 to 110000
and temperature range of 30 to 60oC. The effect of corrosion products formation on the friction factor is studied and
discussed. Corrosion process is analyzed as a mass transfer operation and the mass transfer theory is employed to
express the corrosion rate. The results are compared with many proposed models particularly those based on the
concept of analogy among momentum, heat,
Unknown subsurface leaking water sources and possible subsurface seepage from a sewage tank in a garden at Al-Khawarizmi engineering college, University of Baghdad, were detected in this study. The 2D electrical resistivity imaging. The ERI survey is carried out along two lines, 60m and 50m long, with an electrode spacing of 1 m, forming a cross using the Wenner-Schlumberger array configuration. Line 1 is 60m, while line 2 is 50m. Soil samples were collected from line 1 at positions of electrode 34, which shows a high resistivity value, and electrode 55, which shows low resistivity, for laboratory analysis. Robust inversion and modelling processes showed relative change and high contrast in interpreted resistivities. Soil analy
... Show More