2D Electrical Resistivity has been applied at three selecting areas within the study area using Dipole-dipole and Wenner arrays with an a-spacing of 1 m, and the profile length was 120 m for both. The total data points were 4455 reads for Dipole-dipole, and the total data points for Wenner were 2340 reads, and the depth of each array was 15.4 m and 20.2 m, respectively. The 2D inverse results indicate the resistivity anomalies approximately at depth (2 - 7.8) m formed as a weakness zone lies within the quaternary and Injana Formation deposits and interbedded with secondary gypsum and gypcretes. Additionally, the inverse resistivity distribution model demonstrated that the area is impacted by groundwater that is interaction with sand, silt, and clay of the subsurface layers due to the gypsiferous and gypcrete deposits. They are distinguished by their ability to interact with water, whether it is surface or underground, and as a result, cause the emergence of a set of cavities and voids that may be filled with sediments that contain high levels of water and cause soil to wet. As well, the investigation gives the ideal array as Dipole-dipole rather than Wenner array due to its better in signal to noise ratio and provides the most suitable resolution for these applications, as well as the study, recommends conducting engineering and site investigations of the soil and determining the type of soil and the appropriate treatment methods that can overcome these problems.
The cathodic deposition of zinc from simulated chloride wastewater was used to characterize the mass transport properties of a flow-by fixed bed electrochemical reactor composed of vertical stack of stainless steel nets, operated in batch-recycle mode. The electrochemical reactor employed potential value in such a way that the zinc reduction occurred under mass transport control. This potential was determined by hydrodynamic voltammetry using a borate/chloride solution as supporting electrolyte on stainless steel rotating disc electrode. The results indicate that mass transfer coefficient (Km) increases with increasing of flow rate (Q) where .The electrochemical reactor proved to be efficient in removing zinc and was abl
... Show MoreThe present work determines the particle size based only on the number of tracks detected in a cluster created by a hot particle on the CR-39 solid state nuclear track detector and depending on the exposure time. The mathematical model of the cross section developed here gives the relationship between alpha particle emitting from the (n, α) reaction and the number of tracks created and distribution of tracks created on the surface of the track detector. In an experiment performed during this work, disc of boron compound (boric acid or sodium tetraborate) of different weights were prepared and exposed to thermal neutron from the source. Chemical etching is processes of path formation in the detector, during which a suitable etching solut
... Show MoreOne hundred samples of root canal bacteria were isolated from patients teeth with primary and secondary infected root canal from all the ages . Biochemical and microscopial tests were done for identification of these isolates. Twenty four isolates were confirmed as E. faecalis species by using these tests. Genetic diagnosis for the all isolates was also done by using polymerase chain reaction ( PCR ). Thirty two isolates were confirmed to belong to E. faecalis species by using this test.
Background. Implant insertion in regions with poor bone quantity, such as the posterior maxilla, is potentially associated with an increased rate of implant failure. Calcium sulfate can be used as the coating material for commercially pure titanium (CpTi) and as the bone graft material around implants when bound to eggshell powder to enhance the bone quality and quantity of bone defect regions. This study performed a torque removal test to evaluate the effectiveness of eggshell powder as a bone substitute for filling bone defects around CpTi-coated implants coated with nanocrystalline calcium sulfate. Materials and Methods. Eighty screw implant designs were used in the tibiae of 20 white New Zealand rabbits. A total of uncoated 20 s
... Show More