Preferred Language
Articles
/
ijs-7688
Electron Density Estimation by Electrostatic Probe for Plasma Generated Near the Spacecraft Returning to the Earth's Atmosphere
...Show More Authors

     In this work, the electrostatic probe was utilized to estimate the density of electrons for plasma generated around reentry vehicles that have a geometrically blunt nose at high-altitude. The thermocouple uses to measured electron temperature, which is equal to the temperature of the gas, on board the MAC spacecraft. In the spacecraft backflow field, electrostatic probe measurements were taken at five separate regions 1 to 5 cm from the body of the spacecraft. Over an altitude range of 90 to 50 km with an electron density of 108 to 1012 1/cm3, respectively. The measured electron temperature ranged from 0.05 to 0.9 electron volts and the maximum re-entry velocity of the spacecraft was about 7048 m/s in the re-entry experiment. The cooling using water jet in the flow field, the relationship between electron density, angle of attack changes, and the combustion products of the spacecraft's nose is also discussed.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 20 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Investigation in the Effect of Applied Voltage and Working Pressure on Some Plasma Parameters in the Positive Column of Dc Glow Discharge
...Show More Authors

     Comsol multiphysics software is established to make a simulation that is comparable with experimental device. by utilizing comsol, the positive column domain of direct-current glow discharge with argon is considered for both of different applied voltage and working gas pressure. The calculations are exhibited by using a precise collision cross sections and Townsend coefficients for the argon. The impacts of voltage and pressure on the Debye length, number of particles in Debye sphere and plasma frequency are calculated and graphically delineated. With this regard to the dependence of plasma parameters on the applied voltage and pressure, some of them are found to be compatible with the experimental

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF
Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
Characterization of Laser induced cadmium plasma in air
...Show More Authors

In this paper, the fundamental harmonic of a Nd:YAG laser (Q-switched 1064nm wavelength, 1 Hz repetition rate and 9 ns pulse duration) has been used for the ablation of cadmium samples in air at atmospheric pressure and the generation of the cadmium plasma. The experimentally observed lines of cadmium plasma emission have been used to calculate the plasma parameters such as (electron temperature (TReR), electron density (nReR), Debye length (λRDR) and plasma frequency (ωRpR)). Line pair ratio of neutral species have been used for the electron temperature and electron density measurements. Plasma parameters were studied as a functions of laser pulse energy.

View Publication Preview PDF
Publication Date
Sun Aug 06 2023
Journal Name
Journal Of Economics And Administrative Sciences
Probit and Improved Probit Transform-Based Kernel Estimator for Copula Density
...Show More Authors

Copula modeling is widely used in modern statistics. The boundary bias problem is one of the problems faced when estimating by nonparametric methods, as kernel estimators are the most common in nonparametric estimation. In this paper, the copula density function was estimated using the probit transformation nonparametric method in order to get rid of the boundary bias problem that the kernel estimators suffer from. Using simulation for three nonparametric methods to estimate the copula density function and we proposed a new method that is better than the rest of the methods by five types of copulas with different sample sizes and different levels of correlation between the copula variables and the different parameters for the function. The

... Show More
Publication Date
Wed Oct 28 2020
Journal Name
Iraqi Journal Of Science
Electron Scattering from Some Fp- Shell Nuclei with Inclusion the Effect of Short-Range Correlation
...Show More Authors

The effects of short-range correlation on elastic Coulomb (charge) form factors, charge density distributions as well as root mean square charge radii of various  nuclei (for instance, 46, 48, 50Ti, 52, 54Cr, 56, 58Fe, and 72, 74, 76Ge nuclei) are examined. The one- and two body terms of the cluster expansion together with the single-particle harmonic oscillator wave functions are utilized. For the purpose of embedding these effects into the formulae of charge density  and form factor  we employ the correlation function of Jastrow-type. These formulae depend upon the short-range correlation parameter  (which instigates from the Jastr

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
The effect of current density on the structures and photoluminescence of n-type porous silicon
...Show More Authors

Porous silicon (PS) layers were formed on n-type silicon (Si) wafers using Photo- electrochemical Etching technique (PEC) was used to produce porous silicon for n-type with orientation of (111). The effects of current density were investigated at: (10, 20, 30, 40, and50) mA/cm2 with etching time: 10min. X-ray diffraction studies showed distinct variations between the fresh silicon surface and the synthesized porous silicon. The maximum crystal size of Porous Silicon is (33.9nm) and minimum is (2.6nm) The Atomic force microscopy (AFM) analysis and Field Emission Scanning Electron Microscope (FESEM) were used to study the morphology of porous silicon layer. AFM results showed that root mean square (RMS) of roughness and the grain size of p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of MFI of High-Density Polyethylene on the Mathematical Modeling of Tensile Characteristic
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Jan 02 2023
Journal Name
Pakistan Heart Jornal
The Effect of the Strategy of Differentiated Education According to the Auditory Learning Style by Using Assistance in Learning the Back Kick (T-Chagi) for the Young Players of …
...Show More Authors

Publication Date
Thu Jun 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
Using Genetic Algorithm to Estimate the Parameters of the Gumbel Distribution Function by Simulation
...Show More Authors

In this research, the focus was on estimating the parameters on (min- Gumbel distribution), using the maximum likelihood method and the Bayes method. The genetic algorithmmethod was employed in estimating the parameters of the maximum likelihood method as well as  the Bayes method. The comparison was made using the mean error squares (MSE), where the best  estimator  is the one who has the least mean squared error. It was noted that the best estimator was (BLG_GE).

View Publication Preview PDF
Crossref
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Electron Microscopic Study of the Effects of Preeclampsia on the Placental Endothelial Cells Ultra Structures during Pregnancy
...Show More Authors

Background: Preeclampsia occurs in 3-5% of
pregnancies and is a major cause (12-20 %) of
maternal mortality in developed countries. It is the
leading cause of preterm birth and intra-uterine
growth restrictions (IUGR).
Objective: The study was designed to determine and
demonstrate the ultra structural changes of
endothelial cells in placenta of women suffering from
hypertensive disease.
Patients & Methods: Placental samples were
obtained from two groups of pregnant women
groups (preeclamptic and normal pregnant women).
The specimens were fixed in 2.5% gluteraldehyde
and preceded for electron microscopic examination.
Results: Placenta of women with preeclampsia has
shown marked degenerative

... Show More
View Publication Preview PDF