The main aim of the present paper is to study the electric breakdown in a uniform electric discharge system. The system consists of two spheres separated by a dielectric. The dielectric is dry air. Certain boundary conditions are taken into consideration as applied voltage, pressure, and domain. The formation of discharge types as Townsend and streamer under different distance gaps (1, 0.9,0.8, 0.6, 0.4, 0.2, 0.1) mm was sudied. The temperature effect on the breakdown voltages for the discharge process is also included. Seven different temperature steps are chosen in the study. Comsol Multiphysics software is used for the simulation model as a plasma model. Results show that as the gap distance increases the breakdown voltage increases for each of the discharges. For maximum electric field, as the distance increases the field also increases. For gap distance, the temperature effects are more apparent at the higher values of the pressure. The maximum electric field increases as the voltage increases with the temperature.
An experimental and numerical study has been carried out to investigate the forced convection heat transfer by clean or dusty air in a two dimensional annulus enclosure filled with porous media (glass beads) between two vertical concentric cylinders. The outer cylinder is of (82 mm) outside diameters and the inner cylinder of (27 mm) outside diameter. Under steady state condition; the inner cylinder surface is maintained at a high temperature by applying a uniform heat flux and the outer cylinder surface at an ambient temperature. The investigation covered values of input power of (6.3, 4.884, 4.04 and 3.26 W), Reynolds number values of (300, 700, 1000, 1500, and 2000) and dust ratio values (density number N) of (2, 4, 6 and 8). A comput
... Show MoreThe current study was conducted to demonstrate the effects of air pollution on different biochemical parameters inCitrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected tocollect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and closeto the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonalsamples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters totalchlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugarcontent, proline, electrical conductivity, cadmium and lead. The results of Citr
... Show MorePolycyclic aromatic hydrocarbons (PAHs) were measured in aerosol from air samples, which collected for the period from April 2012 to February 2013, in Baghdad city, at Daura Refinery. Aerosol samples were collected on cellulose fiber filters for 1.5 h in each site for the morning and evening time. These aerosol samples undergone soxhlet extraction.
After the extraction, 49 samples were analyzed by GC-MS in order to determin 16 PAH compounds. The parameters temperature, relative humidity and wind speed were measured during the measurement period. The PAH concentrations were different for location inside and outside Daura refinery. Naphthalene was the most abundant PAH detected in all points at the site sampling for all seasons. There i
The current study was conducted to demonstrate the effects of air pollution on different biochemical parameters in Citrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected to collect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and close to the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonal samples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters total chlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugar content, proline, electrical conducti
... Show MoreIn this work, an experimental study has been done to expect the heat characteristics and performance of the forced-convection from a heated horizontal rectangular fins array to air inside a rectangular cross-section duct. Three several configurations of rectangular fins array have been employed. One configuration without notches and perforations (solid) and two configurations with combination of rectangular-notches and circular-perforations for two various area removal percentages from fins namely 18% notches-9% perforations and 9% notches-18% perforations are utilized. The rectangular fins dimensions and fins number are kept constant. The fins array is heated electrically from the base
... Show MoreShisha smoke represents one of the causes of indoor air pollution. Heavy metals represent the main components in shisha smoke. In this research study, the indoor concentrations of heavy metals in shisha smoke café sites was investigated, samples were taken from two café sites (site1, site 2) which differ in their volume. Site1 volume was 77m3, while site 2 was 437.5m3. Sample were taken by using a low volume sampler (sniffer), and then examined by the Atomic Absorption Spectrometry (AAS). The results showed that indoor air shisha smoke samples for both experimental sites have shown a significant amount of heavy metals as compared with control sampling values. The mean concentration values of (Pb, Zn, Co, Ni, Cr) in site 1 were (11.004,
... Show MoreThe thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and
... Show MoreThe drying process is considered an effective technique for preserving foods and agricultural products from spoilage. Moreover, the drying process lessens the products' weight, volume, and packaging, which prompts a reduction in the products' transportation costs. The drying technique with solar energy represents an ancient method, still alluring due to solar energy abundance and cost‐effectiveness. In this article, the previous manuscripts concerned with studying and analyzing indirect solar dryer systems that utilize innovative solar air heaters (SAHs) are reviewed. The results and conclusions are discussed intensively to clarify the significance of utilizing this type of drying technique. The ef
The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is
... Show More