Frequency-Frequency Interactions in Chaos Communications

In this research, the frequency-frequency interactions in chaotic systems has been experimentally and numerically studied. We have injected two frequencies on chaotic system where one of these frequencies is modulated with chaotic waveform and the other is untiled as a scanning frequency to find modulating frequency. It is observed that the Fast Fourier Transformation (FFT) peaks amplitude increased when the value of the two frequencies are matched. Thus, the modulating frequency could be observed, this leads to discover a new method to detect the modulating frequency without synchronization.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 03 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Acute Gastrointestinal radiation toxicities in pelvic radiation therapy; types, grade and frequency

Background: quality of life of cancer survivors is adversely impacted by bowel toxicity; result from pelvic radiation therapy. In the UK, 12000 patients are treated with radiation therapy for pelvic cancer, mostly with curative intent; this carries a considerable risk for normal surrounding tissues side effects.
Objective: the aim of this study was to determine the frequency, types and grade of acute gastrointestinal toxicity in radical pelvic radiation therapy in our patients so that a comparison could be made with the Western countries.
Patients and Methods: a prospective analytic study was carried out in Radiotherapy department / Oncology teaching hospital / Medical city complex, from the 2nd of January to the 30th of April 2016

... Show More
Crossref
View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
HLA-DRB1*03 And DRB1*15 Frequency In Helicobacter Pylori Superficial Gastritis

Background: Background: Helicobacter pylori is an important gastrointestinal bacteria related to the development of  superficial atrophic gastritis, peptic ulcer and gastric cancer. Human leukocyte antigens (HLA) may play an important roles in host immune responses to H pylori antigens.

Aim of the study: to investigate the association between HLA-DRB1 genotypes and superficial gastritis with H. pylori infection in an Iraqi patients.

Patients and methods: Sixty patients with superficial gastritis and 100 individuals with apparently normal results after endoscopic examination were recruited from Al-Kindy Teaching Hospital - G

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Dec 01 2013
Journal Name
2013 Ieee International Rf And Microwave Conference (rfm)
Differential Evolution algorithm for linear frequency modulation radar signal denoising

Signal denoising is directly related to sample estimation of received signals, either by estimating the equation parameters for the target reflections or the surrounding noise and clutter accompanying the data of interest. Radar signals recorded using analogue or digital devices are not immune to noise. Random or white noise with no coherency is mainly produced in the form of random electrons, and caused by heat, environment, and stray circuitry loses. These factors influence the output signal voltage, thus creating detectable noise. Differential Evolution (DE) is an effectual, competent, and robust optimisation method used to solve different problems in the engineering and scientific domains, such as in signal processing. This paper looks

... Show More
Scopus Crossref
View Publication
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Effect of frequency Chirp on the black and gray solitions

the behavior of the first-order black and gray solitons propagtedin optical fiber in the presence of frequency chirp is studied analytically and numerically results show that phase profile of black solitons changes abruptly

View Publication Preview PDF
Publication Date
Sat Dec 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Design & Implementation of High Switching & Low Phase Noise Frequency Synthesizer

This research  describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc

  The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar &  reference divider in single chip. Therefore our system consists of  a single chip contains (low phase noise PFD, charge pump, prescalar  & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip

... Show More
View Publication Preview PDF
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Study of Crack Effect on Frequency of Simple Supported Beam

In this research the natural frequency of a cracked simple supported beam (the crack is in many places and in different depths) is investigated analytically, experimentally and numerically by ANSYS program, and the results are compared. The beam is made of iron with dimensions of L*W*H= (0.84*0.02* 0.02m), and density = 7680kg/m3, E=200Gpa. A comparison made between analytical results from ANSYS with experimental results, where the biggest error percentage is about (7.2 %) in crack position (42 cm) and (6 mm) depth. Between Rayleigh method with experimental results the biggest error percentage is about (6.4 %) for the same crack position and depth. From the error percentages it could be concluded that the Rayleigh method gives

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 01 2008
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Crossref
View Publication Preview PDF
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Medicine And Life
Arrhythmia related to hypertensive left ventricular hypertrophy in Iraqi patients: frequency and outcome

Left ventricular hypertrophy (LVH) caused by high blood pressure is linked to increased mortality and arrhythmia risk. This study aimed to evaluate arrhythmia in hypertensive patients due to left ventricular hypertrophy (LVH). A cross-sectional study was performed, assessing participants' blood pressure, echocardiography and electrocardiography, and Holter monitoring in certain cases. There were 300 hypertensive patients >18 years attending the cardiology unit of Baghdad medical city. The study was conducted between January–June 2022. The electrocardiograms at rest for 300 adults with hypertension were investigated. 130 (43.5%) were females, and 170 (56.5%) were males. The mean age of participants was 58 years. Forty-nine (16.3

... Show More
Scopus (9)
Crossref (9)
Scopus Crossref
View Publication
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
ADAPTIVE CYCLIC PREFIX LENGTH FOR CONVOLUITIONAL CODE OFDM SYSTEM IN FREQUENCY SELECTIVE CHANNEL

Orthogonal Frequency Division Multiplexing (OFDM) is one of recent years multicarrier modulation used in order to combat the Inter Symbol Interference (ISI) introduced by frequency selective mobile radio channel. The circular extension of the data symbol, commonly referred to as cyclic prefix is one of the key elements in an OFDM transmission scheme. This paper study The influence of the cyclic prefix duration on the BER performance of an OFDM-VCPL (Orthogonal frequency division multiplexing - Variable Cyclic Prefix Length) system and the conventional OFDM system with frame 64-QAM modulation is evaluated by means of computer simulation in a multipath fading channel. The adaptation of CP is done with respect to the delay spread estimation

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Temperature and Frequency on the Dielectric Properties of PVC/MnCl2 Composite

       The dielectric properties of polyvinyl chloride (PVC)-MnCl2 composite were studied by using the impedance technique. The measurements were carried out as a function of frequency in the range from 10 Hz to 13 MHz and temperature range from 27oC to 55oC. Using a composite of 20 wt. % MnCl2 by weight, it was found that the dielectric constants and the dielectric loss of the prepared films increase with the increasing temperature at law frequency and the enhancement of the ionic conduction which is confirmed by the increase the of AC. conductivity and the decrease of the activation energy of the conduction mechanism at high applied frequency. The observed relaxation and polarization effects of composite a

... Show More