The research aims to develop and build a plasma jet system operating under atmospheric pressure.for biological purposes. The advanced plasma system consists of a power supply and a plasma torch. The source of the development of the system is a previous laboratory system that was developed by changing the voltage and frequency of the power supply, as the power provider equips the system with a voltage in the form of a sine wave whose value is fixed at about (7.5kV) peak to peak and its frequency is about (28 kHz). The plasma torch consists of a teflon tube with of width of (10 m ) located at (10mm) from the end of the tube. The current waveform and voltage wave were measured using a current and voltage sensor and an oscilloscope. The plasma jet was characterized. Electron temperature and electron density vary with the gas flow rate; the length of the plasma jet depends on the flow rate of argon gas, and the best length of jetting plasma was (1.5 cm) at a flow rate of (2.5 l/min). The gas temperature was measured by an infrared thermometer at a constant flow rate of (2.5 l/min) which is (18°C) after 15 minutes of irradiation. From these results, it was concluded that the developed plasma is suitable for biological applications.
We have designed, fabricated and studied the vertical axis wind turbine and its characterization. The system has been locally designed to pump water. It is considered as a one of the best options for low speed wind. The turbine has eight blades , each blade is 1.8m in length, and the area dimension of the turbine 3.6 m2 . were investigated the best characterization of the system at low wind speed are Power turbine depends on the wind speed. It was 280 Watt at 6m/s and 160 watt at 5m/s , and the power after the turbine decreasing to factor 1/3. The system torque was 20 N.m , Power coefficient cap 0.29 , Tip speed ratio 0.46. It is suitable to be used in Iraq region , and low cost for get the wat
... Show MoreIn this research, the rabbits' bones have been fractured, the rabbits were exposed to the cold plasma for five minute times two weeks. The microwave plasma voltage which was used in the search was "175v" and the gas flow was" 2 L" at the room temperature. A Biologic parameters such as alkaline phosphates (ALP), osteocalcin, vitamin D (Vit. D) and calcium (Ca), Triglycerides (TG), Cholesterol (T.chol.), Estradiol and Glucose have studied in its serum. Physiological parameters were measured to prove the effects of plasma on the fracture bone tissue and show the amount of damage and the effect of plasma therapy before and after exposure to plasma.
E-learning applications according to the levels of enlightenment (STEM Literacy) for physics teachers in the secondary stage. The sample consists of (400) teachers, at a rate of (200) males (50%), and (200)females (50%), distributed over (6) directorates of education in Baghdad governorate on both sides of Rusafa and Karkh. To verify the research goals, the researcher built a scale of e-learning applications according to the levels of STEM Literacy, which consists of (50) items distributed over (5) levels. The face validity of the scale and its stability were verified by extracting the stability coefficient through the internal consistency method “Alf-Cronbach”. The following statistical means were used: Pearson correlation coefficient,
... Show MoreBackground: Plasma-activated water (PAW) is considered one of the emerging strategies that has been highlighted recently in the food industry for microbial decontamination and mycotoxin detoxification, due to its unique provisional characteristics. Aim: The effectiveness of PAW for aflatoxin B1 (AFB1), ochratoxin A (OTA), and fumonisin B1 (FB1) detoxification in naturally contaminated poultry feeds with its impacts on the feed quality were inspected. Methods: PAW-30 and PAW-60 were utilized for feed treatment for six time durations (5, 10, 15, 20, 40 and 60 min) each. The alterations in the physicochemical properties of PAW after different time durations of plasma inducement and treatment with and without feed samples were monit
... Show MoreIn Automatic Speech Recognition (ASR) the non-linear data projection provided by a one hidden layer Multilayer Perceptron (MLP), trained to recognize phonemes, and has previous experiments to provide feature enhancement substantially increased ASR performance, especially in noise. Previous attempts to apply an analogous approach to speaker identification have not succeeded in improving performance, except by combining MLP processed features with other features. We present test results for the TIMIT database which show that the advantage of MLP preprocessing for open set speaker identification increases with the number of speakers used to train the MLP and that improved identification is obtained as this number increases beyond sixty.
... Show MoreThis paper is concerned with introducing an explicit expression for orthogonal Boubaker polynomial functions with some important properties. Taking advantage of the interesting properties of Boubaker polynomials, the definition of Boubaker wavelets on interval [0,1) is achieved. These basic functions are orthonormal and have compact support. Wavelets have many advantages and applications in the theoretical and applied fields, and they are applied with the orthogonal polynomials to propose a new method for treating several problems in sciences, and engineering that is wavelet method, which is computationally more attractive in the various fields. A novel property of Boubaker wavelet function derivative in terms of Boubaker wavelet themsel
... Show MoreIn this paper, we study flow of photons rate production in a quark-gluon QG plasma. General theory of this study is based on the field theory for hard interaction. The kinetic of photons production from hard interaction in charm with anti-top to production photons with gluon due to plasma phase at high temperatures (150, 200,250,300 and 350 MeV) .It has been investigated and studied using the postulate of quantum chromodynamic theory QCD .The photons production rate of hard photons with( GeV) are insensitive to strength coupling and depend mainly on the temperature of system T . Despite the different critical temperature (150 and 190MeV) comes, we ï¬nd that same order of flow rate photons magnitude in both cases. In both cases, the f
... Show MoreA new test system for detecting environment carcinogenes and/or mutagenes and their adversary It has been induced. One hundred and fifty mutants were isolated from the basidiomycete fungus Coprinus cinereus which were resistant to guanine analogue S- az.aguanine .All the spontaneous and induced with UV light origin mutants were isolated from the wild type strains Bc9/6.6 and Hd5.5
.These mutants were te ted on selective medium containing different
concentrations of the analogue and also to their ability to usc purine bases and their degredated &nbs
... Show MoreRecently, research has focused on non-thermal plasma (NTP) technologies as a way to remove volatile organic compounds from the air stream, due to its distinctive qualities, which include a quick reaction at room temperature. In this work, the properties of the plasma generated by the dielectric barrier discharge (DBD) system and by a glass insulator were studied. Plasma was generated at different voltages (3, 4, 6, 7, 8 kV ) with a fixed distance between the electrodes of 5 mm, and a constant argon gas flow rate of (2.5) I/min. DBD plasma emission spectra were recorded for each voltage. The Boltzmann plot method was used to calculate the electron temperature in the plasma ( ), and the Stark expansion method was used to calculate the elec
... Show MoreThe present work has been characterized by higher order modes in the cavities of the Gyrotron; they are capable of producing RF plasma by developments of it. It uses for fusion systems. We choose the TE31,8 mode in our study. The main problem of gyrotron is the device of the thermal cavity loading. The problem of the thermal loading is solved when any parasitic modes suppress, absence of desired modes; the thermal loading is increased when the high power tube of gyrotron operation is unstable. The mathematical interaction model contains equations that describe the electron motion and the field profiles of the transferred electric modes of the resonator, these are interacting with electrons based
... Show More