MicroRNAs (miRNAs) are small non-coding RNAs that regulate gene expression post-transcriptionally. Transitional cell carcinoma(TCC) of the bladder Cancer (C) account 95 percent of bladder malignancies, with males having a greater prevalence than females. The current study sought to determine whether there is a link between miRNA-29c, miRNA-125, miRNA-141, miRNA-145 and miRNA205 expression levels and TCC/BC risk in Iraqi bladder cancer patients. In the current prospective cross-sectional investigation, 149 samples were collected (95 urine and 54 tissue biopsies). From November 2018 to August 2019, 37/95 urine samples were randomly taken from healthy persons. Total RNA was extracted from tissue and urine samples, and then converted to cDNA via reverse transcription. Quantitate Real-Time-PCR was done using specific primers for quantification of gene expression level of the studied miRNAs. The results showed that 32/49 (65%) patients had non-muscles invasive bladder cancer (stage T1), while 17/49 (35%) patients had muscles invasive bladder cancer (stage T2-T4). Fold change in miRNA-125 expression level showed highly significant differences between non-muscles invasive bladder cancer (T1) and muscles invasion bladder cancer (T2-T4) in both urine and tissue samples biopsies using Chi-square test at p ≤ 0.01. Whereas miR-29c, miR-141, miR-145 and miR-205 showed no significant differences at p > 0.05 between muscles invasive bladder cancer (T1) and muscles invasive bladder cancer (T2-T4) in both urine and tissue biopsies samples. Thus, miR-125 can be associated with the development of invasive stages of TCC-BC as there is an increase in miR-125 expression level in the urine of patients during the final stage of cancer.Hence, this gene could be considered a good predictor in advanced stages of bladder cancer.
This work investigates the structural, optical, and surface properties of ZnO thin films prepared by sol-gel method. The effect on waveguide sensor was examined at different irradiation durations of alpha particles. The X-ray diffraction (XRD) measurements revealed that the crystalline phase of ZnO thin films does not change after irradiation and showed a hexagonal structure of wurtzite type with an orientation toward (002). Moreover, ZnO thin films absorbance was increased with increasing irradiation time, whereas the transmittance was decreased. Additionally, increasing the irradiation time of alpha particles caused an increase in the extinction coefficient and the imaginary part, while the optical energy gap of the ZnO samples w
... Show MoreThe present study is to investigate the possibility of using wastes in the form of scrap iron (ZVI) and/ or aluminum ZVAI for the detention and immobilization of the chromium ions in simulated wastewater. Different batch equilibrium parameters such as contact time (0-250) min, sorbent dose (2-8 g ZVI/100 mL and 0.2-1 g ZVAI/100 mL), initial pH (3-6), initial pollutant concentration of 50 mg/L, and speed of agitation (0-250) rpm were investigated. Maximum contaminant removal efficiency corresponding to (96 %) at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained.
The best isotherm model for the batch single Cr(III) uptake by ZVI
... Show MoreThe modified Hummers method was applied to prepare graphene oxide (GO) from the graphite powder. Tin oxide nanoparticles with different loading (10-20 wt.%) supported on reduced graphene oxide were synthesized to evaluate the oxidative desulfurization efficiency. The catalyst was synthesized by the incipient wetness impregnation (IWI) technique. Different analysis methods like FT-IR, XRD, FESEM, AFM, and Brunauer-Emmett-Teller (BET) were utilized to characterize graphene oxide and catalysts. The XRD analysis showed that the average crystal size of graphene oxide was 6.05 nm. In addition, the FESEM results showed high metal oxide dispersions on the rGO. The EDX analysis shows the weight ratio of Sn is close to its theoretical weight.
... Show MoreWater quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their perfor
... Show MoreA numerical investigation was performed for the radiative magnetohydrodynamic (MHD) viscous nanofluid due to convective stretching sheet. Heat and mass transfer were investigated in terms of viscous dissipations, thermal radiation and chemical reaction. The governing Partial Differential Equations (PDEs) were transformed into an arrangement of non-linear Ordinary Differential Equations (ODEs) by using the similarity transformation. The resulting system of ODEs is solved numerically by using shooting method along with Adams-Moulton Method of order four with the help of the computational software FORTAN. Furthermore, we compared our results with the existing results for especial cases. which are in an excellent agreement. The
numerical
In this paper, an inexpensive, simple and well-accurate process of the generation of bimetallic silver Ag//gold Au core//shell is colloidal metal nanoparticles (MNPs). This is achieved via an atmospheric pressure non-thermal plasma glow discharge between two electrodes. One of these electrodes is a capillary tube placing over solution about (1 cm) that acts as the cathode, while the other electrode is a metal disk immersed in the solution and acts as an anode. Glow discharge process carried out at room temperature using a home-made cell with (6 KV) applied voltage and direct current (DC) about (1.8 mA) for different discharge periods. A wide range of bimetallic Ag//Au colloidal MNPs was rapidly synthesized as a result of non-thermal plas
... Show MoreConcrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show MoreA key agreement protocol (KAP) is a fundamental block in any cryptosystem since it ensures secure communication between two parties. Furthermore, KAP should include advanced features in limited-resource environments such as IoT, in which this protocol must be lightweight and efficient in consuming resources. Despite the Elliptic Curve Diffie-Hellman (ECDH) algorithm having often been considered efficient in providing an acceptable security degree with less resource consumption, it has suffered from weakness against Man-In-The-Middle Attacks (MITMA). This paper presents two versions of the Variant Elliptic Curve Diffie-Hellman (VECDH) algorithms as a key agreement protocol. The security analysis indicates that the proposed algori
... Show MoreSpectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show More