For the determination of metoclopramide hydrochloride (MCPD) in pharmaceutical formulations, a rapid and straightforward spectrophotometric method has been proposed. The method involves diazotizing the main amino group of MCPD with sodium nitrite followed by coupling reaction with reagent 1,7-Dihydroxynaphthalene (1,7-DHN) to form a stable and colored compound in alkaline medium of sodium hydroxide which showed a maximum absorbance intensity at the wavelength 578 nm. The linearity of developed method has ranged from 1.0 - 15 µg.ml-1 while the molar absorptivity 2.9867x104 l.mol-1.cm-1, RSD% was less than 1.11%. While the LOD and LOQ were 0.059 µg.ml-1 and 0.198 µg.ml-1 respectively. The method is appropriate for the determination of MCPD in the presence of other substances that are typically included in dosage forms.
A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreA simple, sensitive, accurate and economic spectrophotometric method has been developed for the determination of sulfacetamide (SFA) in pure form, synthetic sample and urine. The method is based on diazotization of primary amine group of sulfacetamide with sodium nitrite and hydrochloric acid followed by coupling with chromotropic acid in alkaline medium to obtain a stable orange colored chromogen which exhibit a maximum absorption (λmax) at 511.5 nm. Different variables affecting the completion of reaction have been carefully optimized following the classical univariate sequence and modified simplex method (MSM). Under optimized conditions, Beer’s law obeyed in the concentration range of (0.5- &nbs
... Show MoreIn this study, the development of an indirect spectrophotometric method for the determination of folic acid in pure and pharmaceutical preparations is described. The method is based on the oxidation of pyrocatechol with iron (III) in an acidic medium, followed by the reaction with folic acid (FA) to produce a stable, water-soluble orange compound with maximum absorption at 350 nm versus the blank reagent. The complex of charge transfer was studied under optimal conditions; the titration graph was linear over the range of 0.5-25 μg/mL with a relative error of 1.2-2.8 and a relative standard deviation of 2.43-1.45 depending on the concentration level.
The main objective of this paper is to develop and validate flow injection method, a precise, accurate, simple, economic, low cost and specific turbidimetric method for the quantitative determination of mebeverine hydrochloride (MbH) in pharmaceutical preparations. A homemade NAG Dual & Solo (0-180º) analyser which contains two identical detections units (cell 1 and 2) was applied for turbidity measurements. The developed method was optimized for different chemical and physical parameters such as perception reagent concentrations, aqueous salts solutions, flow rate, the intensity of the sources light, sample volume, mixing coil and purge time. The correlation coefficients (r) of the developed method were 0.9980 and 0.9986 for cell
... Show MoreMetoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e
... Show MoreNew, simple and accurate batch and flow injection spectrophotometric
methods have been developed for the determinationsof tetracycline
hydrochloride (TCH) and doxycycline hyclate (DCH) in pharmaceutical
preparations. The methods are based on diazotization of
metchlopramide and coupling reaction with either TCH or DCH in alkaline
medium to form yellow–orange water soluble dye with absorption maxima
at 414 and 436 nm for TCH and DCH, respectively. A graphs of absorbance
versus concentration show that Beer’s law was obeyed over the
concentration ranges of 1 –52 μgmL-1 TCH and DCH for batch method and
of 8 – 240 μg mL-1 TCH and 5 – 350 μgmL-1 DCH for FIA method. The
limits of detection in batchmetho
The drug promethazine hydrochloride (PRZH) forms with rhodium (II) a colored chelate (?max = 472 nm) complex at (pH = 2.1) which is extractable with benzyl alcohol as organic solvent. Under the appropriate experimental conditions a calibration plot was set up from which some analytical parameter were derived and deduced by regression. Standard addition procedure was also adopted. It has been estimated that the concentration of the drug PRZH to be 24.89 mg per unit and 24.19 mg per unit for both calibrations. Under optimal conditions, the developed method has been achieved the following characteristics: LDR (30 – 150 µg ml-1 ) PRZH , RSD % ( 0.6 – 2.47 ) , sandell sensitivity( 0.0844 µg. cm -2 ) , LOD ( 1.66 µgml-1 ) , recovery
... Show MoreA reliable differential pulse polarographic (DPP) method has been developed and applied for the determination of ibuprofen IBU in dosage form with dropping mercury electrode (DME) versus Ag/AgCl. The best peak was found at cathodic peak of -1.18 V in phosphate buffer at pH=4 and 0.025M of KNO3 as supporting electrolyte. In order to obtaine the highest sensitivity, instrumental and experimental parameters were examined including the type and concentration of supporting electrolyte, pH of buffer solution, pulse amplitude and voltage step time. Diffusion current showed a direct linear relationship to ibuprofen concentration in the range of (5 – 30) μg. mL-1 (2.43× 10-5
... Show More