In this study four cheese samples were randomly collected from local markets. These cheese samples were Ishaqi, Danone, Arab white cheese and Agricultural college cheese.
Results obtained revealed that all these cheese samples were contaminated by fungi in addition to the presence of same heavy metals under study which were Fe, Pb, Ni and Cr. All fungal contaminat were identified which were contaminated them in winter (January). However, fungal pollution in summer was 100% while in winter was 50% Aspergillus niger was polluted chees samples100% in summer while it was 75% in winter. Aspergillus fumigatus was polled cheese samples under study 50% in summer and 0% in winter .Results for heavy metals determination revealed that Fe was contaminated cheese samples followed by Ni, Pb and finally Cr and the percentage of their presence was (0.24, 0.006, 0.006, 0.001 ppm) respectively .
The research focuses on determination of best location of high elevated tank using the required head of pump as a measure for this purpose. Five types of network were used to find the effect of the variation in the discharge and the node elevation on the best location. The most weakness point was determined for each network. Preliminary tank locations were chosen for test along the primary pipe with same interval distance. For each location, the water elevation in tank and pump head was calculated at each hour depending on the pump head that required to achieve the minimum pressure at the most weakness point. Then, the sum of pump heads through the day was determined. The results proved that there is a most economical lo
... Show MoreIodide آ in samples آ containing آ magnesium آ fluoride آ was آ determinedآ آ by using iodide selective آ electrode. آ Detecting آ the limit for iodide determination
was around آ 5x1 oآ·5آ آ M with a standard آ deviation آ ranged آ from آ آ± 0.3 to آ± 0.6.
Quantitativeآ آ methodsآ آ including; standard آ additionآ آ method, آ Potentiometric
titration آ by using a Gran plot paper for an equivalent آ point determination and a آ directآ آ methodآ&n
... Show MoreA simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
A reliable differential pulse polarographic (DPP) method has been developed and applied for the determination of ibuprofen IBU in dosage form with dropping mercury electrode (DME) versus Ag/AgCl. The best peak was found at cathodic peak of -1.18 V in phosphate buffer at pH=4 and 0.025M of KNO3 as supporting electrolyte. In order to obtaine the highest sensitivity, instrumental and experimental parameters were examined including the type and concentration of supporting electrolyte, pH of buffer solution, pulse amplitude and voltage step time. Diffusion current showed a direct linear relationship to ibuprofen concentration in the range of (5 – 30) μg. mL-1 (2.43× 10-5
... Show MoreThis work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.
In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it wa
... Show MoreBackground:Many parents of autistic child do well despite their child’s disability, they have the ability to withstand hardship and rebound from adversity, and becoming more strengthened, parents have managed to overcome the constant challenge by using their resilience to adapt well in the face of adversity.
Patients and Methods: A Descriptive analytical study was carried out from May 25, 2009 to June 20, 2010 in order to determine parents' resilience in dealing with the impact of raising a child with autism. A purposive (non-probability) sample of (100) parents raising a child with autism who was attending the out patient psychiatric clinic at Child's Central Teaching Hospital in B
... Show MoreDetermination of Interleukin-8 (IL-8) Levels In Pneumonia Patients