This study uses the optical emission spectroscopy (OES) technique to find the lead(Pb) and sulfur (S) plasma parameters employing a pulse of Nd: YAG laser (Q-switched 1064nm wavelength) and different laser energies of (400,500,600 and 700 mJ). The electron temperature Te (eV) is calculated using the Boltzmann-Plot method, and the electron density ne (cm-3)is determined by the Stark broadened way. Moreover, Debye length λD (cm) and plasma frequency ωp (Hz) are studied as a function of laser energy. An apparent increase was noted in the electron temperature of lead plasma and a decrease in sulfur plasma. The results also showed that each increase in the laser intensity causes an increase in the optical emission peaks. This experiment was carried out under atmospheric pressure.
Polyaniline (PANI) and Ag/PANI nanocomposite thin films have prepared by microwave induced plasma. The Ag powder of average particle size of 50 nm, were used to prepare Ag/PANI nanocomposite thin films. The Ag/PANI nanocomposite thin films prepared by polymerization in plasma and characterized by UV-VIS, FTIR, AFM and SEM to study the effect of silver nanoparticles on the optical properties, morphology and structure of the thin films. The optical properties studies showed that the energy band gap of the Ag/PANI (5%wt silver) decreased from 3.6 to 3.2 eV, where the substrate location varied from 4.4 to 3.4 cm from the axis of the cylindrical plasma chamber. Also the optical energy gap decreased systematically from 3.3 to 3 eV with increas
... Show MoreExperimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre
... Show MoreBiosorption is an effective method to remove toxic metals from wastewaters. In this
study biosorption of lead and chromium ions from solution was studied using
Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The
experimental results showed that optimum grwoth temperature for both bacteria is 30oC
and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the
optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days
and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria
and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and
Pb for C.freundii, C. kosari and in mixes cultu
Biosorption is an effective method to remove toxic metals from wastewaters. In this
study biosorption of lead and chromium ions from solution was studied using
Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The
experimental results showed that optimum grwoth temperature for both bacteria is 30oC
and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the
optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days
and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria
and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and
Pb for C.freundii, C. kosari and in mixes cultu
In this work, different soil samples were brought to study and analyse the element concentrations from different middle regions of Iraq (such as, Habbaniah, Garmah, Fallujah, and Tarmiah cities). Using laser-induced breakdown spectroscopy (LIBS) has been documented as an atomic emission spectroscopy (AES) technique. Laser-induced plasma utilized to analyse elements in materials (gases, liquids, and solids) in order to analyse elements in materials (gases, liquids and solid). The Nd:YAG laser excitation source at 1064nm with pulse width and pulse duration of 9ns is used to generate power density of 5.5 x 1012 MW/mm2, with optical spectrum in the range 320 -740 nm.
The soils of Habbaniyah and Garmah citi
... Show MoreLaser-Induced Breakdown Spectroscopy (LIBS) has been documented as an Atomic Emission Spectroscopy (AES) technique, utilising laser-induced plasma, in order to analyse elements in materials (gases, liquids and solid). The Nd:YAG laser passively Q-switched at 1064nm and 9ns pulse duration focused by convex lens with focal length 100 mm to generates power density 5.5×1012 Mw/mm2 with optical spectrum in the range 320-740 nm. Four soil samples were brought from different northern region of Iraq, northern region (Beiji, Sherkat, Serjnar and Zerkary).
The soil of the Northern region of Beige, Sherkat, Serjnar and Zarkary has abundant ratios of the elements P [0.08, 0.09, 0.18, 0.18] and Ca [0.61, 0.15, 0.92, 0.92] while it lack of Si [0.0
In this work we fabrication holographic optical element diffraction grating thickness 40?m and mirror90?m by using dichromated gelatin,to perform that we have to use the Nd-yaG laser doubling frequency of wavelenght (532)nm and its powers of (80)mWatt.we have studyed the thickness and concentration dichromat effect in mirror reflaction ,effect of angle of reconstruction beam in band width and diffraction efficiency ,study effect gelatin hardener of the diffraction efficiency.
Theoretical calculations are achieved to study the effect of different deuterium pressures on various characteristics parameters for PF400J plasma focus using an international computer code. Axial and radial velocities, voltage tube, plasma temperatures, and neutron yields at different operating deuterium pressures are computed. Neutron emission has been calculated in the device. The maximum total neutron yield calculated is of the order of and neutrons per shot for entire pressure used. The computed results agree reasonably well with the published neutron yield curves.
Environmental exposures to lead remain a serious problem in the developing and industrializing countries. Children are the highest risk aged-group for lead poisoning. This study was designed to assess lead exposure in Al-Fallujah city by analyzing blood lead levels in children and adults and to explain the relationship between blood lead levels, hematological parameters and ferritin levels in the children. The study was performed on-(90) subjects, (65children and 25 adults).Venous blood samples were taken for estimation of hematological parameters, serum ferritin levels and blood lead levels. The children group was subdivided into four groups as: group (A) (low ferritin, low Hb), group (B) (low ferritin, normal Hb), group (C) (normal fer
... Show More