Measurement of Radiation Background and Estimation of the Annual Effective Dose for Workers in the Radiochemistry Laboratories at the Al-Tuwaitha Site
...Show More Authors

      This study was achieved to calculate the annual effective dose equivalent (AEDE) in units of (mSv.y-1), and the average radiation dose rate (ADR) in units of (μSv.h-1) which were measured by portable devices.   The study was carried out on the workers of the destroyed radiochemistry laboratory located at Al-Twuitha nuclear site (south of Baghdad). Radiation background was determined for comparison with the radioactive dose of soil samples measured with HPGe detector and portable devices type LUDLUM.  The radioactivity levels of the area around the radiochemistry laboratory building were within the limits of radiation background.  The result showed a significant increase of the annual effective dose of C1 laboratory workers, as the annual effective dose of the lysate cell 1 (AHC1)in the lab was about 18.995 mSv/y, with an occupancy factor of 0.042, for an average working hours of  one hour per day.  An annual effective dose of 24.073 mSv/y was also recorded in hot cell 2 (HCL2), an increase of more than 4 mSv/y, for an occupancy factor of 0.083, equivalent to 2 hours of work per day.  The glove boxes 11 (GB11) of Laboratory C2 recorded an annual effective dose of 19,720 mSv/y for an occupancy factor of 0.125, equivalent to 3 working hours per day.  The C3 Laboratory and the rest of the laboratories and the health physics rooms recorded an annual effective dose within the workers’ allowable limits of 20 mSv/y.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Engineering And Applied Sciences
Estimation of concentration of radioactive elements for the Liquid Waste pool in radiochemistry laboratories in Al Tuwaitha site Baghdad-Iraq
...Show More Authors

Scopus (3)
Scopus
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Estimation the annual dose for residents in the area around the berms of Al-Tuwaitha nuclear site using RESRAD software
...Show More Authors

RESRAD is a computer model designed to estimate risks and radiation doses from residual radioactive materials in soil. Thirty seven soil samples were collected from the area around the berms of Al-Tuwaitha site and two samples as background taken from an area about 3 km north of the site. The samples were measured by gamma-ray spectrometry system using high purity germanium (HPGe) detector. The results of samples measurements showed that three contaminated area with 238U and 235U found in the study area. Two scenarios were applied for each contaminated area to estimate the dose using RESRAD (onsite) version 7.0 code. The total dose of resident farmer scenario for area A, B and C are 0.854, 0.033 and 2.15×10-3 mSv.yr-1, respectively. Whi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Science
Ionizing Radiation Effect and DNA damage in the workers of Al-Tuwaitha Nuclear Site
...Show More Authors

     Single cell gel electrophoresis (SCGE), also called comet assay, is a rapid and sensitive technique used to analyse DNA Fragmentation Index(DFI). This study aimed to evaluate DNA damage in lymphocytes due to ionizing radiation in workers of Al-Tuwaitha nuclear site, which has been used for nuclear activities and contains a potentially significant amount of radioactive waste.The workers in this site are vulnerable to pollution due to a highly polluted environment of ionizing radiation. Blood samples were collected from 36 workerswho were divided into two groups;8 workers without protection and 28workers with protection, in addition to 30 control subjects.Alkaline comet assay was applied for analysis and the result

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Measurement of indoor radon levels and assessment of radiological hazards at Al-Tuwaitha nuclear site and the surrounding area
...Show More Authors

In the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalatio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Assessment of radiological risk in the area around surface disposal at Al -Tuwaitha site
...Show More Authors

The gamma dose rates and specific activity of 137Cs, 60Co and 40K in
samples of soil taken from places near the landfill radiation at Al-
Tuwaitha site were measured using a portable NaI(Tl) detector. The
results of gamma dose rates in samples were ranged from 52.6
nGy.h-1 to 131nGy.h-1. Then the specific activity of 137Cs, 60Co and
40K in soil were determined using high pure germanium (HPGe)
detector. The specific activities were varied from 1.9 to 115500 Bq.
kg-1 for 137Cs, from 6.37 to 616.5 Bq. kg-1 for 60Co, and from 3 to
839.5 Bq. kg-1 for 40K. The corresponding health risk for the annual
effective dose equivalent varied from 1.85×10-14 to 15.7mSv/y. The
results were compared with various internationa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Measurement of radionuclides in imported Coffee Consumed in Basra southern of Iraq and estimation of its annual effective dose
...Show More Authors

Radioactive elements were identified in samples of imported coffee consumed in the province of Basra using gamma spectrometry SAM940TM. It is a scintillation detector of NaI(Tl) crystal and the dimensions of 2×2 inch. We have identified specific concentration As(Bq/kg) and annual effective dose D(Sv/y) for radioactive elements (_^40)K, (_^131)I, (_^134)Cs and (_^137)Cs. The estimated average effective dose for adults from coffee samples were found to be 0.037mSv/y, 88.434nSv/y, 46.909nSv/y, 27.212nSv/y for ((_^40)K,(_^131)I,(_^134)Cs,(_^137)Cs) respectively. The present results of the study revealed that the radioactivity was relatively low in the coffee and within the permissiblelimit.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Radioactivity and annual effective dose in some types of drug
...Show More Authors

The aim of this research is to know danger of radioactive isotopes
that are found in samples of drugs traded in Iraqi markets. The
samples are Iraqi Amoxicillin, English Amoxicillin, UAE
Amoxicillin, Indian Amoxicillin, Iraqi Paracetamol, English
Paracetamol, UAE Paracetamol and Indian Paracetamol. By high
purity germanium the activity of the following isotopes 40K, 214Pb,
228Ac and 137Cs is measured and the specific activity was used to
calculate the annual effective dose. Then the calculated annual
effective dose values are compared with the allowable annual
effective dose values of each part of digestive channel. This research
concluded that the measured annual effective dose values are not
dangerous.<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Baghdad Science Journal
Measurement of the Radon Concentration and Annual Effective Dose in Malva sylvestris (Khabbaz) Plant Used in Traditional Medicine and Food
...Show More Authors

In this study, the radon gas concentration as well as the annual effective dose in leaves of the Malvasylvestris (Khabbaz) plant used in the traditional treatment and as food in Iraq, for this, it is necessary to evaluate the concentrations radon gas, which were measured using solid state nuclear track detectors (SSNTDs) CR-39 technique.  The  concentration and annual effective dose in samples were collected from Baghdad city ranged from minimum to maximum value 15.815 , 0.498 , 54.445 , 1.717  respectively, while the values of  concentration and annual effective dose in a sample collected from Karbala are 15.297 ,0.482 . These values of  concentration and annual effective dose less were compared with th

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Radiological risk assessment of fuel fabrication facility at Al- Tuwaitha nuclear site
...Show More Authors

The specific activity of 29 soil samples collected from Fuel
Fabrication Facility FFF at AL-Tuwaitha site, 20 km south of
Baghdad were determined using HPGe detector in a low background
configuration, it's relative efficiency of 40%, and resolution of 2keV
for the 1332 keV gamma ray emission of 60Co. The range of activity
concentrations of 226Ra, 232Th and 40K were between (12.56-31.96),
(10.2-18.4) and (47.47-402.1) Bq/kg respectively. In order to assess
any radiological hazard to human health, the absorbed gamma dose
rate D in air at 1m above the ground surface was calculated in the
range (18.87 to 36.46) nGy/h; the outdoor annual effective dose
equivalent AEDE was evaluated to vary from 0.0039 to 0.0076

... Show More
View Publication
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Radiation doses assessment for workers on radiation measuring devices response check in RNSD laboratories
...Show More Authors

Radiation measuring devices need to periodic calibration process to examine their sensitivity and the extent of the response. This study is used to evaluate the radiation doses of the workers in the laboratories of the Directorate of Safety as a result of the use of point sources in calibrating of the devices in two ways, the first is the direct measurement by the FAG device and the others using RESRAD and RAD PRO programs. The total doses values using FAG were (2.57 μSv/y, 102.3 μSv/y and 20.75 μSv/y for TLD laboratory, Gamma spectroscopy analyses (GSA) laboratory and equipment store respectively, and the total doses that calculated using RESRAD and RAD PRO were 1.518 μSv/y, 76.65 μSv/y and 21.2 μSv/y for the above laboratories. t

... Show More
View Publication Preview PDF
Crossref