A New Chromogenic Reagent for Determination of Copper (II) in Water Samples Using Flow injection-Technique.

A new flow injection spectrophotometric method is described for the determination of copper ion Cu(II) in water samples (tap water and river water).The proposed method based on the formation of red complex [Cu(L)2(NO3)2] which has a maximum absorption at λmax=490 nm. Linear range for Cu (II) was from 5-70μg/mL with detection limit 2.55μg/mL. The effect of physical and chemical parameters were evaluated .The proposed method was applied successfully for determination of copper (II) in the tap and river water. [Cu(L)2(NO3)2] complex was prepared in a (2:1) mole ratio as ( reagent: copper (II)).The analytical reagent formed by reaction of thymol with 4-aminoantipyrine at room temperature. The metal complex was characterized by IR, UV-Visible spectra. The metal percentage, electrical conductivity and magnetic properties of the formed complex confirmed that this chromogenic reagent was coordinated with copper (II) metal ion through oxygen and nitrogen atoms of the phenol and amine group as a bidentate ligand with octahedral geometry.

View Publication
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Thymol Using Procaine Hydrochloride as a New Chromogenic Reagent

New, simple and sensitive batch and Flow-injecton spectrophotometric methods for the determination of Thymol in pure form and in mouth wash preparations have been proposed in this study. These methods were based on a diazotization and coupling reaction between Thymol and diazotized procaine HCl in alkaline medium to form an intense orange-red water-soluble dye that is stable and has a maximum absorption at 474 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 0.4-4.8 and 4-80 µg.ml-1 of Thymol, with detection limits of 0.072 and 1.807 µg.ml-1 of Thymol for batch and FIA methods respectively. The FIA procedure sample throughput was 80 h-1. All different chemical and physical e

... Show More
Crossref
View Publication Preview PDF
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric and Reverse Flow Injection Method Determination of Nitrazepam in Pharmaceuticals Using O-Coumaric Acid as a New Chromogenic Reagent

            A spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the   determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples

... Show More
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Spectrophotometric Determination of Vancomycin Hydrochloride (Batch and Flow-Injection) Using O-Nitroaniline as diazotized Chromogenic Reagent

New, simple and sensitive batch and nFIA spectrophotometric methods for the determination of Vancomycin Hydrochloride in pure form and in pharmaceutical preparations were proposed, These method's were based on diazotization and coupling reaction between Vancomycin Hydrochloride and diazotized O-nitroaniline in alkaline medium to form Orange water-soluble dye that is stable and has a maximum absorbance at 465nm. Acalibration graph shows that aBeer's law is obeyed over the concentration range of 0.8-60 and 5-400 μg.mL-1 of Vancomycin Hydrochloride with detection limit's of 0.16 and 1.666 μg.mL-1 of Vancomycin Hydrochloride for batch and nFIA methods, respectively. The FIA procedure sample throughput was 80 h-1. All different chemicals an

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
With Solvent Extraction Method, and via new Organic Reagent 2-(Benzo thiazolyl azo)-4,5- Diphenyl Imidazole for Spectrophotometric Determination of Copper (II) in different Samples

The new organic reagent 2-[Benzo thiazolyl azo]-4,5-diphenyl imidazole was prepared and used as complexing agent for separation and spectrophotometric determination of Cu2+ ion in some samples include plants, soil, water and human blood serum. Initially determined all factors effect on extraction method and the results show optimum pH was (pHex=9), optimum concentration was 40?g/5mLCu2+ and optimum shaking time was (15min.), as well stoichiometry study appears the complex structure was 1:1 Cu2+: BTADPI. Interferences effect of cations were studied. Synergism effect shows MIBK gave increasing in distribution ratio (D). Organic solvent effect appears there is no any linear relation between dielectric constant for organic solvent used and dis

... Show More
Crossref
View Publication Preview PDF
Publication Date
Mon Jun 17 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of Manganese (II) using Flow Injection Analysis with Chemiluminescence detection

The determination of manganese (II) using flow injection analysis with chemiluminescence detection was investigated. Mn2+ in sample solutions injected into a carrier stream of sodium bismuthate (NaBiO3) were oxidised to form MnO4- ions which were capable of producing luminescence after reaction with luminol/KOH in a flow cell. The linear range of the system is from 20 to 80 mg/L with a detection limit 8 mg/L. The proposed system is suitable for determination of Mn2+ in steel alloys after dissolution, filtration and dilution at a rate of approximately 60 samples per hour with a relative standard deviation (RSD)1.2%. Statistical comparison between the proposed system and standard spectrophotometric method revealed that there is no signific

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Review using continuous flow injection analysis technique in the determination of several drugs

Continuous flow injection analysis (CFIA) is one of the simplest, easiest, and multilateral analytical automation methods in moist chemical analysis. This method depends on changing the physical and chemical properties of a part of the specimen spread out from the specimen injected into the carrier stream. The CFIA technique uses automatic analysis of samples with high efficiency. The CFIA PC compatibility also allows specimens to be treated automatically, reagents to be added, and reaction conditions to be closely monitored. The CFIA is one of the automated chemical analysis methods in which a successive specimen sample is to be estimated and injected into a vector stream from a flowing solution that meets the reagent and mixes at a spe

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser

A newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Continuous Flow Injection Analysis for The Photometric Determination of Metformin Drug Via The Release of Copper(II) ion from Charged Gel Bead Crystal

A newly developed analytical method characterized by its speed and sensitivity for the determination of metformin-HCl via the formation of complex for metformin-HCl-OH--copper(II) ion from the gel bead system by continuous flow injection analysis. The method is based on the imbedded copper(II) ion in the gel bead structure can be used in the reaction for the formation of red –magneta colour complex(λmax. =530nm) formed by direct reaction of the drug with the released copper (II) ion from the gel bead in alkaline medium. Linear dynamic range for the absorbance versus metformin concentration was 0.001-1 mmol.L-1 while C.O.D was (r2% =95.33%) . The L.O.Q was 0.868mmol.L-1.L.O.D (S/N=3)=0.5μmol.L-1 from the step wise dilution for the min

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Promethazine-HCl Determination Using Entrapped Persulphate in Water Crystals by Flow Injection / Stopped - Flow Technique and Ayah 3SX3-3D Solar Cell Micro Photometer

A new mode of methodology was adopted in the assay of PM- HCL based on the use of water crystal gel bead made of poly acrylic acid in which the gel beads were left to absorbe persulphate solution that is necessary for the oxidation of PM- HCL in aqua media . The water crystal act as a reserviour for S2O82- . Optimum parameters were studied giving to specify the chemical and physical parameters. Two line manifold was used .The flow rates of 1.5 and 1.2 ml.min-1 was used , 3 gel beads , 120 μL sample volume , a linear dynamic range extend from 0.01- 18 mmol.L-1. A correlation coefficient (r) of 0.9991while the percentage linearity (r2%) of 99.82% with R.S.D% at 8 mmol.L-1 promethazine-HCl is less than 0.5% (ten replicates) and a detection

... Show More
View Publication Preview PDF