Glitches are sudden increases in the rotational frequency (ν) of a neutron star.
Glitches usually occur as fractional increase in the frequency of the order of ⁄
= - .In this work we study the glitch in normal and magnetar pulsar stars,
glitches are small or absent in the millisecond pulsar star because it is old star
whereas the weak glitch activity of young pulsars by the fact that their internal
temperatures are still too high for the crust to store a large stress .The results showed
that NART (pulsed emission only at infrared) normal pulsar has more glitches than
AXP (Anomalous X-ray Pulsar) and HE (Spin-powered pulsar with pulsed emission
from radio to infrared or higher frequencies) stars, as the same time HE stars have
more glitches than AXP, in a good agreement with the previous studies. From the
results can be conclude that study of neutron star glitches is a very important study
in the evolution of neutron star as it helps in probing the neutron star interior.
The business environment is witnessing great and rapid developments due to the economic and technological development that has caused damage to human beings, which requires the need to reduce this damage and work to protect the environment and participate in supporting the social aspects. This requires economic resources to be realized by the economic units. Economic development in preserving the environment that has caused damage and supporting the social aspects that preserve human rights, enhance their position and satisfy their needs in society. Global professional organizations, the United Nations and stakeholder representatives have been issuing the Global Reporting Initiative (GRI) to find guidelines for the preparation of
... Show MoreAmongst the literary writers who used their art to direct the attention towards the issue of woman and her rights in a proper life is the English poet and novelist Thomas Hardy (1840-1928), who has been praised for his “openness to the feminine principle” 1 as Irving Howe put it. Hardy’s wide readings have changed his way of dealing with and thinking about so many critical issues which started to float on the surface of the English society during the mid and late of the 19th century. His readings for a number of writers, who seem of huge impact on his writings as he later admits that – “[his] pages show harmony of view with
... Show MoreFour samples of the Se55S20Sb15Sn10 alloy were prepared using the melting point method. Samples B, C and D were irradiated with (6.04×1010, 12.08×1010 and 18.12×1010 (n.cm-2s -1 ) of thermal neutron beam from a neutron source (241Am-9Be) respectively, while sample A was left not irradiated. The electrical properties were assessed both before and after the radiation. All irradiated and non-irradiated samples show three conduction mechanisms, at low temperatures, electrical conductivity is achieved by electron hopping between local states near the Fermi level. At intermediate temperatures, conduction occurs by the jumping of electrons between local states at band tails. At high temperatures, electrons transfer between extended stat
... Show MoreTheoretical calculations are achieved to study the effect of different deuterium pressures on various characteristics parameters for PF400J plasma focus using an international computer code. Axial and radial velocities, voltage tube, plasma temperatures, and neutron yields at different operating deuterium pressures are computed. Neutron emission has been calculated in the device. The maximum total neutron yield calculated is of the order of and neutrons per shot for entire pressure used. The computed results agree reasonably well with the published neutron yield curves.
Background: The anterior loop of mental nerve is commonly described as that part of the neurovascular bundle that transverses anterior and inferior to the mental foramen only to loop back to exit the mental foramen. The aim of the study is to evaluate the incidence and extension of anterior loop of mental nerve by using digital panoramic imaging system to avoid nerve damage during different surgical procedures in dentistry. Materials and Method: Panoramic image was taken for all 400 patients and stored in the computer. Then Horizontal and Vertical for the anterior loop extension when exist was measured and recorded in a special case sheet prepared for each subject. Results: Results indicated that out of 400 patients there were only 25 pat
... Show MoreThis paper aimed to test random walking through the ISX60 market index for the ability to judge market efficiency at a weak level. The study used Serial Correlation Test, the Runs Test, the Variance Ratio Test, as well as the Rescaled Range Test.The population of the study represents of Iraq Stock Exchange. The study concluded accepting the hypothesis of the study that the returns of the ISX60 market index in the Iraqi market for securities does not follow the random walking in general and as a result the Iraq market for securities is inefficient within the weak level of efficiency and the study recommended need a supervisors work in the Iraqi market for securities to activate all means a which will work to communication with information
... Show MoreDrilling with casing (DWC) can be considered as a modern drilling technique in which both of drilling and casing operations done in the same time by using the casing to transfer the hydraulic and mechanical power to the bit instead of traditional drilling string. To overcome oil well control, minimizing the total cost through enhancing drilling efficiency, drilling with casing was proposed as an enabling technology.
Two surface sections (17 1/2 - and 12 1/4- inch) were drilled successfully in Rumaila oil field with casing strings which reached 655m and 1524m measured depths respectively.
By using DWC technique, the total drill/case phase time was reduced up to 20% comparing to conventional
... Show MoreBackground: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial s
... Show MoreThis paper presents experimental results regarding the behaviours of eight simply supported partially prestressed concrete beams with internally unbonded tendons, focusing particularly on the effect of three different variables: concrete compressive strength,