Preferred Language
Articles
/
ijs-5809
Evaluation of the antibacterial effects of Eucalyptus camaldulensis L., Glycyrrhiza glabra L. and Morus nigra L. extracts against some pathogenic bacteria in vitro
...Show More Authors

This study aimed to test the effect of using different concentrations of three different plants extracts to inhibit the growth of gram negative and gram positive bacteria by two technics. Eucalyptus camaldulensis bark, Glycyrrhiza glabra rhizomes and Morus nigra leaves ethanolic extract at (0,20,30,40 and 50 mg/ml) were used. The antimicrobial activity and the biofilm inhibition assay used with these extracts showed positive effect in inhibiting the growth of bacteria. E.amaldulensis extract showed the higher effect than G. glabra and M.nigra extracts in antimicrobial activity assay, while the effect of E. camaldulensis extract in biofilm inhibition assay was higher than G. glabra that was higher than M. nigra extracts for both gram negative and positive bacteria. These results confirmed the effect of E. camaldulensis, G. glabra and M. nigra extracts on retarding the growth of bacteria.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 05 2017
Journal Name
Chemical Engineering Communications
Microwave-assisted preparation of mesoporous-activated carbon from coconut (<i>Cocos nucifera</i>) leaf by H<sub>3</sub>PO<sub>4</sub>activation for methylene blue adsorption
...Show More Authors

View Publication
Scopus (100)
Crossref (96)
Scopus Clarivate Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Iraqi Journal Of Science
Assessment of ISNAG fluorimeter (Total fluorescence measurements at+ 90° & - 90° using four solar cell on each side for 100mm distance at 2mm path length) with well-known fluorescent molecules via CFIA
...Show More Authors

Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95

... Show More
View Publication Preview PDF