Comparison of Some Statistical Measurements Extracted From Benign, Malignant and Normal MRI Brain Images
...Show More Authors

People may believe that tissue of normal brain and brain with benign tumor
have the same statistical descriptive measurements that are significantly different
from the of brain with malignant tumor. Thirty brain tumor images were collected
from thirty patients with different complains (10 normal brain images, 10 images
with benign brain tumor and 10 images with malignant brain tumor). Pixel
intensities are significantly different for all three types of images and the F-test was
measured and found equal to 25.55 with p-value less than 0.0001. The means of
standard deviations and coefficients of variation showed that pixel intensities from
normal and benign tumors images are almost have the same behavior whereas they
were significantly different from images of malignant brain tumors with F-tests
equal to 23.22 and 6.51 respectively with corresponding p-values of 0.00001 and
0.005 respectively.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2005
Journal Name
Iraqi Journal Of Science
Comparison between Zernike moment and central moments for matching problem
...Show More Authors

Moment invariants have wide applications in image recognition since they were proposed.

Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Comparison between Modified Weighted Pareto Distribution and Many other Distributions
...Show More Authors

 

In 2020 one of the researchers in this paper, in his first research, tried to find out the Modified Weighted Pareto Distribution of Type I by using the Azzalini method for weighted distributions, which contain three parameters, two of them for scale while the third for shape.This research compared the distribution with two other distributions from the same family; the Standard Pareto Distribution of Type I and the Generalized Pareto Distribution by using the Maximum likelihood estimator which was derived by the researchers for Modified Weighted Pareto Distribution of Type I, then the Mont Carlo method was used–that is one of the simulation manners for generating random samples data in different sizes ( n= 10,30,50), and in di

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Comparison of HF and HCl Chemical Laser Parameters by using Mathematical Model
...Show More Authors

A simplified theoretical comparison of the hydrogen chloride (HCl) and hydrogen fluoride (HF) chemical lasers is presented by using computer program. The program is able to predict quantitative variations of the laser characteristics as a function of rotational and vibrational quantum number. Lasing is assumed to occur in a Fabry-Perot cavity on vibration-rotation transitions between two vibrational levels of hypothetical diatomic molecule. This study include a comprehensive parametric analysis that indicates that the large rotational constant of HF laser in comparison with HCl laser makes it relatively easy to satisfy the partial inversion criterion. The results of this computer program proved their credibility when compared with th

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Al-qadisiyah Medical Journal
Comparison between dome and wedge osteotomy in management of hallux valgus deformity
...Show More Authors

Background: the condition of hallux valgus is considered as the most common deformities affecting females more than males, characteristically manifested as lateral deviation of the big toe and widening of first and second inter -metatarsal angle with a deformity of second toe in some severe cases. Objective: to make a radiological and clinical assessment of two surgical methods of osteotomy used in treatment of hallux valgu and to compare between them: first one is the distal dome osteotomy, and second one is a distal wedge metatarsal osteotomy. Patients and methods: a total of 36 feet of 28 patients suffer from hallux valgus, with mean age of 50.3 years were included in this study, followed for 6- 30 months ( mean follow-up of 8.8 months).

... Show More
Publication Date
Sun Jan 30 2022
Journal Name
Iraqi Journal Of Science
Diagnosis of Malaria Infected Blood Cell Digital Images using Deep Convolutional Neural Networks
...Show More Authors

     Automated medical diagnosis is an important topic, especially in detection and classification of diseases. Malaria is one of the most widespread diseases, with more than 200 million cases, according to the 2016 WHO report. Malaria is usually diagnosed using thin and thick blood smears under a microscope. However, proper diagnosis is difficult, especially in poor countries where the disease is most widespread. Therefore, automatic diagnostics helps in identifying the disease through images of red blood cells, with the use of machine learning techniques and digital image processing. This paper presents an accurate model using a Deep Convolutional Neural Network build from scratch. The paper also proposed three CNN

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (6)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Calculating land surface temperature of South Baghdad by the using Landsat 8 images
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Aug 28 2020
Journal Name
Iraqi Journal Of Science
De-Noising of Corrupted Fluoroscopy Images Based on a New Multi-Line Algorithm
...Show More Authors

 Fluoroscopic images are a field of medical images that depends on the quality of image for correct diagnosis; the main trouble is the de-nosing and how to keep the poise between degradation of noisy image, from one side, and edge and fine details preservation, from the other side, especially when fluoroscopic images contain black and white type noise with high density. The previous filters could usually handle low/medium black and white type noise densities, that expense edge, =fine details preservation and fail with high density of noise that corrupts the images. Therefore, this paper proposed a new Multi-Line algorithm that deals with high-corrupted image with high density of black and white type noise. The experiments achieved i

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Oct 23 2020
Journal Name
Palarch’s Journal Of Archaeology Of Egypt/egyptology
A Multimodal Discourse Analysis of Visual Images in UNHCR Reports on Displaced Iraqis
...Show More Authors

The advent of UNHCR reports has given rise to the uniqueness of its distinctive way of image representation and using semiotic features. So, there are a lot of researches that have investigated UNHCR reports, but no research has examined images in UNHCR reports of displaced Iraqis from a multimodal discourse perspective. The present study suggests that the images are, like language, rich in many potential meanings and are governed by clearly visual grammar structures that can be employed to decode these multiple meanings. Seven images are examined in terms of their representational, interactional and compositional aspects. Depending on the results, this study concludes that the findings support the visual grammar theory and highlight the va

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Science
A Technique for Estimating Degradation Parameters for Medical Images Blind Restoration
...Show More Authors

      Restoration is the main process in many applications. Restoring an original image from a damaged image is the foundation of the restoring operation, either blind or non-blind. One of the main challenges in the restoration process is to estimate the degradation parameters. The degradation parameters include Blurring Function (Point Spread Function, PSF) and Noise Function. The most common causes of image degradation are errors in transmission channels, defects in the optical system, inhomogeneous medium, relative motion between object and camera, etc. In our research, a novel algorithm was adopted based on Circular Hough Transform used to estimate the width (radius, sigma) of the Point Spread Function. This algorithm is based o

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Hybrid Techniques with Support Vector Machine for Improving Artifact Ultrasound Images
...Show More Authors

     The most common artifacts in ultrasound (US) imaging are reverberation and comet-tail. These are multiple reflection echoing the interface that causing them, and result in ghost echoes in the ultrasound image. A method to reduce these unwanted artifacts using a Otsu thresholding to find region of interest (reflection echoes) and output applied to median filter to remove noise. The developed method significantly reduced the magnitude of the reverberation and comet-tail artifacts. Support Vector Machine (SVM) algorithm is most suitable for hyperplane differentiate. For that, we use image enhancement, extraction of feature, region of interest, Otsu thresholding, and finally classification image datasets to normal or abnormal image.

... Show More
View Publication Preview PDF
Scopus Crossref