Preferred Language
Articles
/
ijs-5574
Comparison of Some Statistical Measurements Extracted From Benign, Malignant and Normal MRI Brain Images
...Show More Authors

People may believe that tissue of normal brain and brain with benign tumor
have the same statistical descriptive measurements that are significantly different
from the of brain with malignant tumor. Thirty brain tumor images were collected
from thirty patients with different complains (10 normal brain images, 10 images
with benign brain tumor and 10 images with malignant brain tumor). Pixel
intensities are significantly different for all three types of images and the F-test was
measured and found equal to 25.55 with p-value less than 0.0001. The means of
standard deviations and coefficients of variation showed that pixel intensities from
normal and benign tumors images are almost have the same behavior whereas they
were significantly different from images of malignant brain tumors with F-tests
equal to 23.22 and 6.51 respectively with corresponding p-values of 0.00001 and
0.005 respectively.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 01 2011
Journal Name
Iop Conference Series: Materials Science And Engineering
Contour extraction of echocardiographic images based on pre-processing
...Show More Authors

In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Algorithm Development for Full Gaps of Landsat 7 Images
...Show More Authors

      Landsat7 of Enhanced thematic mapper plus (ETM+) was launched on April 15,  1999. Four years later, images start degrading due to the scan line corrector (SLC). SLC is a malfunction that results in pixel gaps in images captured by the sensor of Landsat7. The pixel gap regions extend from about one pixel near the image center and reach up to about 14 pixels in width near the image edge. The shape of this loss is like a zigzag line; however, there are different studies about repairing these gaps. The challenge of all studies depends on retrieving inhomogeneous areas because the homogenous area can be retrieved quickly depending on the surrounding area. This research focuses on filling these gaps by utilizing pixels around them

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri May 17 2013
Journal Name
International Journal Of Computer Applications
Fast Lossless Compression of Medical Images based on Polynomial
...Show More Authors

In this paper, a fast lossless image compression method is introduced for compressing medical images, it is based on splitting the image blocks according to its nature along with using the polynomial approximation to decompose image signal followed by applying run length coding on the residue part of the image, which represents the error caused by applying polynomial approximation. Then, Huffman coding is applied as a last stage to encode the polynomial coefficients and run length coding. The test results indicate that the suggested method can lead to promising performance.

View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Iraqi Journal Of Science
Restoration of Digital Images Using an Iterative Filter Algorithm
...Show More Authors

Digital image started to including in various fields like, physics science, computer science, engineering science, chemistry science, biology science and medication science, to get from it some important information. But any images acquired by optical or electronic means is likely to be degraded by the sensing environment. In this paper, we will study and derive Iterative Tikhonov-Miller filter and Wiener filter by using criterion function. Then use the filters to restore the degraded image and show the Iterative Tikhonov-Miller filter has better performance when increasing the number of iteration To a certain limit then, the performs will be decrease. The performance of Iterative Tikhonov-Miller filter has better performance for less de

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 01 2010
Journal Name
2010 Ieee Symposium On Industrial Electronics And Applications (isiea)
Effectiveness of the cumulative vs. normal mode of operation for combinatorial testing
...Show More Authors

View Publication
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Natural radioactivity Measurements of Dur-Kurigalzu's Ziggurat, Baghdad Governorate-Iraq using HPGe detector
...Show More Authors

       Measurement of 238U, 233Th and 40K concentrations in soil samples collected from Ziggurat of Dur-Kurigalzu west region of Baghdad, have been evaluated, using high purity germanium detector. The activity concentrations of 238U, 233Th and 40K varied from 16.040  to 26.620 , 14.510  to 31.480 , and 153.820  to 266.320  with average values of 20.604±2.9 , 24.534±3.3 , 212.22±25.1 , respectively. The importance of these measurements lies in the estimation of radiation risk, radium equivalent, absorbed dose, annual effective dose, risk indices, gamma index, and cancer risk. The average value of the absorbed dose ranged from 33.187  outdoors to 63.111  indoo

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Oct 30 2017
Journal Name
International Journal Of Science And Research
Measurements of X-Ray Dose Delivered at Different Depths Applied on Water Phantom
...Show More Authors

Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1

... Show More
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Using K-mean Clustering to Classify the Kidney Images
...Show More Authors

      This study has applied digital image processing on three-dimensional C.T. images to detect and diagnose kidney diseases.  Medical images of different cases of kidney diseases were compared with those of   healthy cases. Four different kidneys disorders, such as stones, tumors (cancer), cysts, and renal fibrosis were considered in additional to healthy tissues. This method helps in differentiating between the healthy and diseased kidney tissues. It can detect tumors in its very early stages, before they grow large enough to be seen by the human eye. The method used for segmentation and texture analysis was the k-means with co-occurrence matrix. The k-means separates the healthy classes and the tumor classes, and the affected

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Building a Statistical Model to Detect Foreground Objects and using it in Video Steganography
...Show More Authors

Video steganography has become a popular option for protecting secret data from hacking attempts and common attacks on the internet. However, when the whole video frame(s) are used to embed secret data, this may lead to visual distortion. This work is an attempt to hide sensitive secret image inside the moving objects in a video based on separating the object from the background of the frame, selecting and arranging them according to object's size for embedding secret image. The XOR technique is used with reverse bits between the secret image bits and the detected moving object bits for embedding. The proposed method provides more security and imperceptibility as the moving objects are used for embedding, so it is difficult to notice the

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of The College Of Education For Women
Second Language Learning and Its Relationship with the Third Language Learning: Statistical Study: China
...Show More Authors

The exchanges in various fields,like economics, science, culture, etc., have been enhanced unceasingly among different countries around the world in the twenty-first century, thus, the university graduate who masters one foreign language does not meet the need of the labor market in most countries.So, many universities began to develop new programs to cultivate students who can use more foreign languages to serve the intercultural communication. At the same time, there is more scientific research emerged which is related to the relationship between the second and third languages. This humble research seeks to explain the relevant concepts and analyze the real data collected from Shanghai International Studies University in China, to expl

... Show More
View Publication Preview PDF