Preferred Language
Articles
/
ijs-5528
Medical Image Denoising with Wiener Filter and High Boost Filtering

     The Wiener filter is widely used in image de-noising. It is used to reduce Gaussian noise. Although the Wiener filter removes noise from the image, it causes a loss of edge detail information, resulting in blurring of the image. The edge details are considered high-frequency components. The Wiener filter is unable to reconstruct these components. In this paper, the proposed filter based on the Wiener filter and the high-boost filter for medical images is presented. The proposed filter is applied to the degraded image. First, using Fourier Transformation, the degraded image and the high boost filter are converted in the frequency domain. Secondly, the wiener filter is applied to the image along with the high boost filter. Thirdly, the deconvolution process is achieved on the image with the high boost filter. Finally, to reconstruct the sharper image in the spatial domain, the inverse of the Fourier transformation is applied. The proposed filter works to suppress the additive noise at the same time. It can keep the image's edge details. Some focus operators are used, which are image contrast, gradient energy, histogram entropy, and spatial frequency, in order to test the proposed algorithm. Experimental results showed that the proposed filter gives good results compared with the traditional filters for medical images, especially dark images.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Iraqi Journal Of Science
Detection and Discrimination for Shadow of High Resolution Satellite Images by Spatial Filter

This paper presents a new and effective procedure to extract shadow regions of high- resolution color images. The method applies this process on modulation the equations of the band space a component of the C1-C2-C3 which represent RGB color, to discrimination the region of shadow, by using the detection equations in two ways, the first by applying Laplace filter, the second by using a Kernel Laplace filter, as well as make comparing the two results for these ways with each other's. The proposed method has been successfully tested on many images Google Earth Ikonos and Quickbird images acquired under different lighting conditions and covering both urban, roads. Experimental results show that this algorithm which is simple and effective t

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 14 2018
Journal Name
International Journal Of Engineering & Technology
Hybrid DWT-DCT compression algorithm & a new flipping block with an adaptive RLE method for high medical image compression ratio

Huge number of medical images are generated and needs for more storage capacity and bandwidth for transferring over the networks. Hybrid DWT-DCT compression algorithm is applied to compress the medical images by exploiting the features of both techniques. Discrete Wavelet Transform (DWT) coding is applied to image YCbCr color model which decompose image bands into four subbands (LL, HL, LH and HH). The LL subband is transformed into low and high frequency components using Discrete Cosine Transform (DCT) to be quantize by scalar quantization that was applied on all image bands, the quantization parameters where reduced by half for the luminance band while it is the same for the chrominance bands to preserve the image quality, the zig

... Show More
Crossref
View Publication
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
Comparative Study of Image Denoising Using Wavelet Transforms and Optimal Threshold and Neighbouring Window

NeighShrink is an efficient image denoising algorithm based on the discrete wavelet
transform (DWT). Its disadvantage is to use a suboptimal universal threshold and identical
neighbouring window size in all wavelet subbands. Dengwen and Wengang proposed an
improved method, which can determine an optimal threshold and neighbouring window size
for every subband by the Stein’s unbiased risk estimate (SURE). Its denoising performance is
considerably superior to NeighShrink and also outperforms SURE-LET, which is an up-todate
denoising algorithm based on the SURE. In this paper different wavelet transform
families are used with this improved method, the results show that Haar wavelet has the
lowest performance among

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Technique For Image De-blurring Using Adaptive Wavelet Lagrange Fuzzy Filter

A new de-blurring technique was proposed in order to reduced or remove the blur in the images. The proposed filter was designed from the Lagrange interpolation calculation with adjusted by fuzzy rules and supported by wavelet decomposing technique. The proposed Wavelet Lagrange Fuzzy filter gives good results for fully and partially blurring region in images.
 

View Publication Preview PDF
Publication Date
Tue May 16 2023
Journal Name
International Journal Of Online And Biomedical Engineering (ijoe)
Watermarking in Medical Image

Medical image security is possible using digital watermarking techniques. Important information is included in a host medical image in order to provide integrity, consistency, and authentication in the healthcare information system. This paper introduces a proposed method for embedding invisible watermarking in the 3D medical image. The cover medical image used is DICOM which consists of a number of slices, each one representing a sense, firstly must separate the ROI (Region of Interest) and NROI (Not Region Of Interest) for each slice, the separation process performed by the particular person who selected by hand the ROI. The embedding process is based on a key generated from Arnold's chaotic map used as the position of a pixel in

... Show More
Scopus (1)
Scopus Clarivate Crossref
View Publication
Publication Date
Mon Aug 26 2019
Journal Name
Iraqi Journal Of Science
Medical Image Enhancement to Extract Brain Tumors from CT and MRI images

     Always MRI and CT Medical images are noisy so that preprocessing is necessary for enhance these images to assist clinicians and make accurate diagnosis. Firstly, in the proposed method uses two denoising filters (Median and Slantlet) are applied to images in parallel and the best enhanced image gained from both filters is voted by use PSNR and MSE as image quality measurements. Next, extraction of brain tumor from cleaned images is done by segmentation method based on k-mean.  The result shows that the proposed method is giving an optimal solution due to denoising method which is based on multiple filter types to obtain best clear images and that is leads to make the extraction of tumor more precision best.<

... Show More
Scopus (4)
Crossref (2)
Scopus Crossref
View Publication Preview PDF
Publication Date
Wed May 31 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Retrieving Image from Noisy Version depending on Multiwavelet Soft-Thresholding with Smoothing Filter

In this paper, we describe a new method for image denoising. We analyze properties of the Multiwavelet coefficients of natural images. Also it suggests a method for computing the Multiwavelet transform using the 1st order approximation. This paper describes a simple and effective model for noise removal through suggesting a new technique for retrieving the image by allowing us to estimate it from the noisy image. The proposed algorithm depends on mixing both soft-thresholds with Mean filter and applying concurrently on noisy image by dividing into blocks of equal size (for concurrent processed to increase the performance of the enhancement process and to decease the time that is needed for implementation by applying the proposed algorith

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 04 2023
Journal Name
Exergy - New Technologies And Applications
High Synthetic Image Coding System

Compressing an image and reconstructing it without degrading its original quality is one of the challenges that still exist now a day. A coding system that considers both quality and compression rate is implemented in this work. The implemented system applies a high synthetic entropy coding schema to store the compressed image at the smallest size as possible without affecting its original quality. This coding schema is applied with two transform-based techniques, one with Discrete Cosine Transform and the other with Discrete Wavelet Transform. The implemented system was tested with different standard color images and the obtained results with different evaluation metrics have been shown. A comparison was made with some previous rel

... Show More
Crossref
View Publication
Publication Date
Mon Apr 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Detect The Infected Medical Image Using Logic Gates

   This paper determined the difference between the first image of the natural and the second infected image by using logic gates. The proposed algorithm was applied in the first time with binary image, the second time in the gray image, and in the third time in the color image. At start of proposed algorithm the process  images by applying convolution to extended images with zero to obtain more vision and features then enhancements images by Edge detection filter (laplacion operator) and smoothing images by using mean filter ,In order to determine the change between the original image and the injury the logic gates applied specially X-OR gates . Applying the technique for tooth decay through this comparison can locate inj

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 30 2018
Journal Name
Iraqi Journal Of Science
Analytical Study of Medical Image Combination Techniques

Image combination is a technique that fuses two or more medical images taken with different conditions or imaging devices into a single image contain complete information. In this study relied on mathematical, statistical and spatial techniques, to fuse MRI images that captured horizontal and vertical times (T1, T2),  and applied a method of supervised classification based on the minimum distance before and after combination process, then examine the quality of the resulting image based on the statistical standards resulting from the analysis of edge analysis, showing the results to identify the best techniques adopted in combination process, determine the exact details in each class and between classes.

View Publication Preview PDF