Preferred Language
Articles
/
ijs-5492
Plasma Properties of a Low-Pressure Hollow Cathode DC Discharge
...Show More Authors

      The current study involves an experimental investigation of plasma main parameters of a DC discharge with a hollow cathode (HCD) geometry in air using apertures of different diameters from the hollow cathode (1, 1.5, 2, and 2.5 cm). A tiny Langmuir probe is used to investigate the plasma properties. The HCD was operated at constant power of 12.4 W and gas pressures ranging between 0.1 to 0.8 torr. It was observed that the operational conditions strongly affect the electron temperature and density, while the hollow cathode diameter has not much influence. The main important observation was that at relatively high air pressure (>0.4 torr) two electron temperatures were obtained, while at relatively low pressure (<0.4 torr), a single electron temperature was found. The results showed that the measured electron temperature decreased nearly linearly with increasing gas pressure.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Structural and mechanical properties of dental amalgam record locally
...Show More Authors

The dental amalgam of radioactive materials in the restoration of teeth because of its readily adaptable to existing materials in the oral cavity in addition to mechanical properties such as hardness mechanical resistance Alndgat and others in this study were prepared Almlagm used Guy dental restoration of silver alloy tin plus some elements to improve the characteristicsmechanical such as copper, zinc or indium in addition to mercury

View Publication Preview PDF
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Development the Mechanical Properties of (AL-Li-Cu) Alloy
...Show More Authors

The aim of this research is to develop mechanical properties of a new aluminium-lithium-copper alloy. This alloy prepared under control atmosphere by casting in a permanent metal mould. The microstructure was examined and mechanical properties were tested before and after heat treatment to study the influence of heat treatment on its mechanical properties including; modulus of elasticity, tensile strength, impact, and fatigue. The results showed that the modulus of elasticity of the prepared alloy is higher than standard alloy about 2%. While the alloy that heat treated for 6 h and cooled in water, then showed a higher ultimate tensile stress comparing with as-cast alloy. The homogenous heat treatment gives best fatigue

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Synthesis and electrical properties of conductive polyaniline/ SWCNT nanocomposites
...Show More Authors

The synthesis of conducting polyaniline (PANI) nanocomposites containing various concentrations of functionalized single-walled carbon nanotubes (f-SWCNT) were synthesized by in situ polymerization of aniline monomer. The morphological and electrical properties of pure PANI and PANI/SWCNT nanocomposites were examined by using Fourier transform- infrared spectroscopy (FTIR), and Atomic Force Microscopy (AFM) respectively. The FTIR shows the aniline monomers were polymerized on the surface of SWCNTs, depending on the -* electron interaction between aniline monomers and SWCNTs. AFM analysis showed increasing in the roughness with increasing SWCNT content. The AC, DC electrical conductivities of pure PANI and PANI/SWCNT nanocomposite h

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Study the Electrical Properties of Carbon Nanotubes/Polyaniline Nanocomposites
...Show More Authors

Several schottky diodes were fabricated from polyaniline/ Carbon nanotube (single and multiwalled) composites. These composites were synthesized with different concentration and two carbon nanotubes types, Single and Multi-Walled Carbon Nanotubes (SWCNT & MWCNT). Aluminum and silver paste were chosen as schottky and ohmic contact respectively. physical and electrical were used to studied these composite by using Atomic Force Microscopy (AFM) and electrical measurements. The Root Mean Square RMS surface roughness of the composite samples was found to be around 4nm. The currentvoltage characteristic were measurements for all samples in the bias range ±15V at room temperature. The results shows the increasing in carbon nanotubes concentration

... Show More
View Publication Preview PDF
Crossref (3)
Clarivate Crossref
Publication Date
Wed May 25 2022
Journal Name
Iraqi Journal Of Science
The Effect of Cold Plasma on pH, Creatine, and the Concentration of the Most Trace Elements in Human's Nails by Using X-ray Fluorescent Method
...Show More Authors

     The aim of this study is to determine the effect of cold plasma on nails pH, creatine levels and the accumulative of some trace elements in humans nails. Creatine levels in the blood, as well as pH and trace elements, were measured before and after (1, 2) months of plasma exposure in both gender (men and women) between the ages of 22 and 25 years. Nails are exposed to  cold plasma with a voltage of (175 volts) and (2 gas flow). After one month of exposure, there was no significant change in the levels of all parameters, but after 2 months, the concentration of creatine and pH had  reached  a near- neutral value. In both men and women,  calcium concentration increased and showed a positive response to cold plasma, while the v

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Quantitative detection and correlation of Epstein - Barr Virus in plasma with gingivitis and severity of chronic periodontitis by using real-time polymerase chain reaction technique
...Show More Authors

Background: The main purpose of this study is to find if there is any correlation between the level of C-reactive protein (CRP) in gingival crevicular fluid with its serum level in chronic periodontitis patients and to explore the differences between them according to the probing depth. Materials and methods: Forty seven male subjects enrolled in this study. Thirty males with chronic periodontitis considered as study group whom further subdivided according to probing depth into subgroup 1 with pocket depth ≤6mm, subgroup 2 with pocket depth >6mm. The other 17 subjects considered as controls. For all subjects, clinical examination where done for periodontal parameters plaque index (PLI), gingival index (GI), bleeding on probing (BOP),

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of poly propylene fibers incorporation and their oxygen plasma treatment on tensile strength, wettability and wear resistance of heat cure denture base acrylic resin
...Show More Authors

Background: Recently, Poly propylene fibers with and without plasma treatment have been used to reinforce heat cure denture base acrylic but, so far some of properties like tensile strength , wettability and wear resistance not evaluated yet, the aim of the study is to clarify the influence of incorporation of treated and untreated fibers on these properties. Materials and methods: Twenty one specimens were fabricated for every tested property(tensile strength, wear resistance and wettability) that classified into three groups(control, untreated poly propylene fibers reinforced specimens and Oxygen plasma treated group)and for each test sevens amples were used(n=7). Tensile strength was tested using Instron universal testing machine, wear

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 25 2019
Journal Name
Separation Science And Technology
Green synthesis of graphene-coated sand (GCS) using low-grade dates for evaluation and modeling of the pH-dependent permeable barrier for remediation of groundwater contaminated with copper
...Show More Authors

Scopus (20)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Civil Engineering And Technology
Properties of reactive powder concrete with different types of cement
...Show More Authors

Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Study of the mechanical properties of Iron-Epoxy composite materials
...Show More Authors

Iron-Epoxy composite samples were prepared by added
different weight percentages (0, 5, 10, 15, and 20 wt %) from Iron
particles in the range of (30-40μm) as a particle size. The contents
were mixed carefully, and placed a circular dies with a diameter of
2.5 cm. Different mechanical tests (Shore D Hardness, Tensile
strength, and Impact strength ) were carried out for all samples. The
samples were immersed in water for ten weeks, and after two weeks
the samples were take-out and drying to conducting all mechanical
tests were repeated for all samples. The hardness values increased
when the Iron particle concentration increased while the Impact
strength is not affected by the increasing of Iron particles
c

... Show More
View Publication Preview PDF
Crossref