Multiple sclerosis (MS) is one of an autoimmune condition with uncertain etiopathology. According to new data, ABO system had played a role in the development and understanding numerous diseases. Lower level of 25-hydroxy vitamin D3 (25-OHD3) is considered as a risk factor for MS. The aims of this study is to identify the role of blood group distribution on the levels of parathyroid hormone (PTH), 25-OHD3, total calcium, inorganic phosphorus and total magnesium on MS patients. Additionally, we assessed the relation between Expanded Disability Status Scale (EDSS) and study parameters in patients. The Study included 107 patients with MS were distributed in to four groups according to their blood group (A, B, AB, and O). Additionally, 124 apparently healthy individuals as control group. Tukey analysis was showed the level of 25-OHD3 in patients with B+ was significant decrease than O+ and A+ patients group (P≤0.05). Furthermore, EDSS was negatively correlated with 25-OHD3 (P≤0.05) in B+ and O+ patient groups. Through this study, ABO group may be consider as a risk factor for MS susceptibility as another interesting variable.
Polymorphisms in the genes of G-protein subunit beta 3 (GNB3); rs5443, tryptophan hydroxylase 1 (TPH1); rs211105 and rs4537731, tryptophan hydroxylase 2 (TPH2); rs4570625 and sodium voltage-gated channel alpha subunit 5 (SCN5A); rs1805124, have known to cause the abnormalities in the gastrointestinal tract that are implicated to irritable bowel syndrome (IBS) predisposition. Upfront genetic polymorphism genotyping in IBS-related gene polymorphisms will help to intervene and guide the decision-making in the management of IBS patients. This study aimed to develop a genotyping method to detect the respective polymorphisms using nested allele-specific multiplex polymerase chain reaction (NASM-PCR). A combi
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreA simple, rapid and sensitive spectrophotometric method has been proposed for the determination of La (III) using 3-hydroxy -4-(2-hydroxy-phenyl azo) naphthalene -1- sulfonic acid as a chromogenic reagent. This method is based on the formation of a red-pink colored complex, upon the reaction of La(III) with the reagent in an alkaline medium (pH= 9.50), having a maximum absorbance at 459 nm. Beer's law is valid in the concentration range 0.512 µg.ml-1 with a Sandell's sensitivity value of 0.0188 µg.cm-2 and molar absorptivity of 7376.12 L.mol-1.cm-1. The stoichiometric composition of the chelate is 1:3. The effect of the presence of different cations as interferants in the determination of La(III) under the given optimum conditions
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreAbstract: Background: Staphylococcus aureus is Gram-positive bacteria that lives as a normal flora in living organisms but can be pathogenic to humans. Although a relatively unspectacular, nonmotile coccoid bacterium, S. aureus is a dangerous human pathogen in both community-acquired and nosocomial infections. Due to the increasing emergence of new strains of this antibiotic-resistant bacteria, it has become essential to approach different methods to control this pathogen. One of these methods is the antimicrobial photodynamic inactivation process using a low-level laser, in this paper, the Photodynamic effects of Rose Bengal and LLLL on the virulence factors of S.aureus were evaluated.
The aim of this article is to solve the Volterra-Fredholm integro-differential equations of fractional order numerically by using the shifted Jacobi polynomial collocation method. The Jacobi polynomial and collocation method properties are presented. This technique is used to convert the problem into the solution of linear algebraic equations. The fractional derivatives are considered in the Caputo sense. Numerical examples are given to show the accuracy and reliability of the proposed technique.
Isolation and identification of bacterial isolates were carried out according to the morphology and biochemical characteristics on one hundred and twenty stool specimens collected from children under five years old via using biochemical tests and Api 20E compact system for further confirmation. Bacterial isolates were distributed as (34.48, 20.68, 5.17,0.86) % for Escherichia coli, Salmonella typhi ,Enterobacter aerogenos, Citrobacter freundii and Hafnia alvei respectively and 9.48 % for each Proteus mirabilis, Pseudomonas aeruginosa and Klebsiella Pneumonia. As well as, 2.58% for both Shigella sonnei and Serratia marcescens. Antibiotic susceptibility test for 116 bacterial isolates was performed towards 20 antibiotics types using disk d
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show More