Preferred Language
Articles
/
ijs-4625
Low Latency UHD Adaptive Video Bitrate Streaming Based on HEVC Encoder Configurations and Http2 Protocol
...Show More Authors

      Applying 4K, (Ultra HD) Real-time video streaming via the internet network, with low bitrate and low latency, is the challenge this paper addresses. Compression technology and transfer links are the important elements that influence video quality. So, to deliver video over the internet or another fixed capacity medium, it is essential to compress the video to more controllable bitrates (customarily in the 1-20 Mbps range). In this study, the video quality is examined using the H.265/HEVC compression standard, and the relationship between quality of video and bitrate flow is investigated using various constant rate factors, GOP patterns, quantization parameters, RC-lookahead, and other types of video motion sequences. The ultra-high-definition video source is used, down sampled and encoded at multiple resolutions of (3480x2160), (1920x1080), (1280x720), (704x576), (352x288), and (176x144). To determine the best H265 feature configuration for each resolution experiments were conducted that resulted in a PSNR of 36 dB at the specified bitrate. The resolution is selected by delivery (encoder resource) based on the end-user application. While video streaming adapted to the available bandwidth is achieved via embedding a controller with MPEG DASH protocol at the client-side. Video streaming Adaptation methods allow the delivery of content that is encoded at different representations of video quality and bitrate and then dividing each representation into chunks of time. Through this paper, we propose to utilize HTTP/2 as a protocol to achieve low latency video streaming focusing on live streaming video avoiding the problem of HTTP/1.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 11 2025
Journal Name
Chemical And Process Engineering Research
Spectrophotometric Determination of Sulfanilamide in Pure and in Synthetic Sample based on Condensation Reaction Method
...Show More Authors

A new, Simple, sensitive and accurate spectrophotometric methods have been developed for the determination of sulfanilamide (SNA) drug in pure and in synthetic sample. This method based on the reaction of sulfanilamide (SNA) with 1,2-napthoquinone-4-sulphonic acid (NQS) to form N-alkylamono naphthoquinone by replacement of the sulphonate  group of the naphthoquinone sulphonic acid by an amino group. The colored chromogen shows absorption maximum at 455 nm. The optimum conditions of condensation reaction forms were investigated by: (1) univariable method, by optimizing the effect of experimental variables; (different bases, reagent concentration, borax concentration and reaction time),     (2) central  composite design (CCD) including

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
The Digital Change Detection for Low Resolution Satellite Images in Weathering Estimation
...Show More Authors

      The detection and estimation of weathering conditions have become a very important daily necessity in our life. For this purpose, several satellites of low resolution imagery were launched by the weathering and environmental agencies. The important weather paremeters are temperuter, wind direction,  velocity, clould and humidity, etc. The low resolution images often deal with large-scale phenomena and the interpretation and projection of the produced data requires continuous development of tools and criteria.              In this paper, the low spatial resolution data generated by the moderate resolution imaging spectroradiometer (MODIS) were used to monitor the cloud density and direction above Iraq and i

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Dec 03 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Condition assessment and rehabilitation for trunk sewer deterioration based on Semi-Markov model
...Show More Authors

An accurate assessment of the pipes’ conditions is required for effective management of the trunk sewers. In this paper the semi-Markov model was developed and tested using the sewer dataset from the Zublin trunk sewer in Baghdad, Iraq, in order to evaluate the future performance of the sewer. For the development of this model the cumulative waiting time distribution of sewers was used in each condition that was derived directly from the sewer condition class and age data. Results showed that the semi-Markov model was inconsistent with the data by adopting ( 2 test) and also, showed that the error in prediction is due to lack of data on the sewer waiting times at each condition state which can be solved by using successive conditi

... Show More
Publication Date
Wed Sep 26 2018
Journal Name
Communications In Computer And Information Science
A New RGB Image Encryption Based on DNA Encoding and Multi-chaotic Maps
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Tue Sep 10 2019
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
A classification model on tumor cancer disease based mutual information and firefly algorithm
...Show More Authors

View Publication
Scopus (14)
Crossref (5)
Scopus Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Journal Of Science
Automatic Short Answer Grading System Based on Semantic Networks and Support Vector Machine
...Show More Authors

      In education, exams are used to asses students’ acquired knowledge; however, the manual assessment of exams consumes a lot of teachers’ time and effort. In addition, educational institutions recently leaned toward distance education and e-learning due the Coronavirus pandemic. Thus, they needed to conduct exams electronically, which requires an automated assessment system. Although it is easy to develop an automated assessment system for objective questions. However, subjective questions require answers comprised of free text and are harder to automatically assess since grading them needs to semantically compare the students’ answers with the correct ones. In this paper, we present an automatic short answer grading metho

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 04 2018
Journal Name
Wireless Personal Communications
IFRS: An Indexed Face Recognition System Based on Face Recognition and RFID Technologies
...Show More Authors

View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Thu Jun 06 2024
Journal Name
Journal Of Applied Engineering And Technological Science (jaets)
Deep Learning and Its Role in Diagnosing Heart Diseases Based on Electrocardiography (ECG)
...Show More Authors

Diagnosing heart disease has become a very important topic for researchers specializing in artificial intelligence, because intelligence is involved in most diseases, especially after the Corona pandemic, which forced the world to turn to intelligence. Therefore, the basic idea in this research was to shed light on the diagnosis of heart diseases by relying on deep learning of a pre-trained model (Efficient b3) under the premise of using the electrical signals of the electrocardiogram and resample the signal in order to introduce it to the neural network with only trimming processing operations because it is an electrical signal whose parameters cannot be changed. The data set (China Physiological Signal Challenge -cspsc2018) was ad

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Modeling and analysis of thermal contrast based on LST algorithm for Baghdad city
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Iraqi Journal Of Science
Paper based glucose biosensor depending on SPCE modified with hemoglobin and silver nanoparticles
...Show More Authors

The direct electron transfer behavior of hemoglobin that is immobilized onto screen-printed carbon electrode (SPCE) modified with silver nanoparticles (AgNPs) and chitosan (CS) was studied in this work. Cyclic voltametry and spectrophotometry were used to characterize the hemoglobin (Hb) bioconjunction with AgNPs and CS. Results of the modified electrode showed quasi-reversible redox peaks with a formal potential of (-0.245 V) versus Ag/AgCl in 0.1 M phosphate buffer solution (PBS), pH7, at a scan rate of 0.1 Vs-1. The charge transfer coefficient (α) was 0.48 and the apparent electron transfer rate constant (Ks) was 0.47 s-1. The electrode was used as a hydrogen peroxide biosensor with a linear response over 3 to 240 µM and a detection li

... Show More
Scopus