Preferred Language
Articles
/
ijs-4317
Surface Plasmon Resonance (SPR) Simulation of a Gold-Bismuth Bi-layer Gas Sensor
...Show More Authors

      The features of plasmonic surface frequency sensor technology, such as the small number of sensor samples required, electromagnetic interference, and high sensitivity, have been found to be highly important.. In this paper, a simulation program was created in Matlab_b2018 by adopting Fresnel equations for calculating the reflectivity of the electromagnetic wave between different media. A surface plasmon resonance sensor based on electromagnetic wavelengths within the range (100 nm to 1000 nm) has been proposed. The transfer matrix was used for a system consisting of four different media. The first medium is a semicircular BK7 glass prism, the second medium is a gold layer (40 nm thick), then a bismuth layer of variable thicknes(10–80) nm, and the last medium is air as the sensing medium. The surface plasmon resonance (SPR) technique was adopted based on the Kretschmann configuration in the simulation of the proposed system.  The simulation results showed that there is no SPR within the range of wavelengths (100-500nm), while SPR appears in the visible region and in the IR region at wavelengths (900 and 1000nm). The SPR phenomenon starts to weaken gradually with an increase in the thickness of the bismuth layer. The full width at half maximum (FWHM) decreases with the decrease of thickness of bismuth layer. The best value for it is (10) at thickness (d=10 nm) and wavelength (900 nm). While the height (H) of the SPR dip increased, with the best value of (0.95) at thickness (d=10 nm) and wavelength (700 nm). Also, the sensitivity increased with increasing the bismuth layer thickness at wavelengths (700 , 800,

and 1000 ) nm. The highest obtained sensitivity(S) was (112.5 deg/RIU).

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2011
Journal Name
College Of Engineering Journal
Study the Effect of Cutting Conditions for turning process on the Machined Surface
...Show More Authors

Surfaces quality is one of the most specified customer requirements for machine parts. The major indication of surfaces quality on machined parts is surface roughness. The research aim is to study the cutting conditions and their effects on the surface roughness. This paper utilizes regression models to predict surface roughness over the machining time for variety of cutting conditions in turning. In the experimental part for turning, different types of materials (Aluminum alloy, Copper alloy, and Gray cast iron) were considered with different cutting speed ( ) and feed rate ( ). A mathematical Model depending on statistical-mathematical method between surface roughness (Rz ) and cutting condition ( , ) were derived, for the three materials

... Show More
Publication Date
Mon Apr 01 2019
Journal Name
Plant Archives
Surface epidermis of leaf and indumentum for five species of the genus Galium in Iraq
...Show More Authors

The current investigation included study of leaf surface epidermis beside indumentum for the species Galium aparine L., G. ceratopodum Boiss, G. setaceum Lam., G. spurium L., and G. tricornatum Dandy, the study showed that paracytic type of stomatal complex is the only type occur in leaf. The indumentum compose of eglandular hairs vary in their apices, length and occurrence of different part of plant body

View Publication
Scopus
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Enhanced hydrogen gas sensitivity employing sputtered deposited NiO thin films
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Sat Feb 27 2021
Journal Name
Iraqi Journal Of Science
DC Glow Discharge Plasma Characteristics in Ar/O2 Gas Mixture
...Show More Authors

In this article, the effects of the O2 ratio  on the electrical characteristics, including the I-V characteristic curve, Panchen’s curve, and I-P curve, were tested in a sample of O2/Ar gaseous mixture . The sample was produced by plasma-based DC magnetron sputtering with niobium metal as a target material. The inter-electrode spacing value was 4 cm. Plasma diagnosis via the Optical Emission Spectroscopy (OES) method was used to achieve Te and Ne mixture values of 20 %, 30 %, 50%, and 70% in the Ar/O2 system. The results showed that the discharge is operating in the abnormal glow region and the discharge current was decreased by increasing O2 percentage. In addition, the experimenta

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Handbook Of Polymer Nanocomposites For Industrial Applications
Polyaniline-graphite nanocomposite based modified cladding optical fiber gas sensors
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Apr 19 2023
Journal Name
Lasers In Medical Science
Immunohistochemistry technique for effect of gold nanoparticles, laser, and photodynamic therapy on FoxP1 level in infected mice with mammary adenocarcinoma
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue Jun 03 2014
Journal Name
Heat Transfer - Asian Research
CFD Simulation of Heat Transfer Augmentation in a Circular Tube fitted with Alternative Axis Twisted Tape in Laminar Flow under the Constant Heat Flux
...Show More Authors

Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Photoacoustic Imaging for Tumor Detection: An in vitro Simulation Study
...Show More Authors

Photoacoustic is a unique imaging method that combines the absorption contrast of light or radio frequency waves with ultrasound resolution. When the deposition of this energy is sufficiently short, a thermo-elastic expansion takes place whereby acoustic waves are generated. These waves can be recorded and stored to construct an image. This work presents experimental procedure of laser photoacoustic two dimensional imaging to detect tumor embedded within normal tissue. The experimental work is accomplished using phantoms that are sandwiched from fish heart or blood sac (simulating a tumor) 1-14mm mean diameter embedded within chicken breast to simulate a real tissue. Nd: YAG laser of 1.064μm and 532nm wavelengths, 10ns pulse duration, 4

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 26 2022
Journal Name
Iraqi Journal Of Science
Estimating the Reliability Function for Transmuted Pareto Distribution Using Simulation
...Show More Authors

     In this work, the methods (Moments, Modified Moments, L-Moments, Percentile, Rank Set sampling and Maximum Likelihood) were used to estimate the reliability function and the two parameters of the Transmuted Pareto (TP) distribution. We use simulation to generate the required data from three cases this indicates  sample size , and it replicates  for the real value for parameters, for reliability times values  we take .

Results were compared by using mean square error (MSE), the result appears as follows :

The best methods are Modified Moments, Maximum likelihood and L-Moments in first case, second case and third case respectively.

View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Economics And Administrative Sciences
Estimating the general exponential distribution parameters using the simulation method
...Show More Authors

The main aim of this paper is to study how the different estimators of the two unknown parameters (shape and scale parameter) of a generalized exponential distribution behave for different sample sizes and for different parameter values. In particular, 

. Maximum Likelihood, Percentile and Ordinary Least Square estimators had been implemented for different sample sizes (small, medium, and large) and assumed several contrasts initial values for the two parameters. Two indicators of performance Mean Square Error and Mean Percentile Error were used and the comparisons were carried out between different methods of estimation  by using monte carlo simulation technique .. It was obse

... Show More
View Publication Preview PDF
Crossref