Preferred Language
Articles
/
ijs-4317
Surface Plasmon Resonance (SPR) Simulation of a Gold-Bismuth Bi-layer Gas Sensor
...Show More Authors

      The features of plasmonic surface frequency sensor technology, such as the small number of sensor samples required, electromagnetic interference, and high sensitivity, have been found to be highly important.. In this paper, a simulation program was created in Matlab_b2018 by adopting Fresnel equations for calculating the reflectivity of the electromagnetic wave between different media. A surface plasmon resonance sensor based on electromagnetic wavelengths within the range (100 nm to 1000 nm) has been proposed. The transfer matrix was used for a system consisting of four different media. The first medium is a semicircular BK7 glass prism, the second medium is a gold layer (40 nm thick), then a bismuth layer of variable thicknes(10–80) nm, and the last medium is air as the sensing medium. The surface plasmon resonance (SPR) technique was adopted based on the Kretschmann configuration in the simulation of the proposed system.  The simulation results showed that there is no SPR within the range of wavelengths (100-500nm), while SPR appears in the visible region and in the IR region at wavelengths (900 and 1000nm). The SPR phenomenon starts to weaken gradually with an increase in the thickness of the bismuth layer. The full width at half maximum (FWHM) decreases with the decrease of thickness of bismuth layer. The best value for it is (10) at thickness (d=10 nm) and wavelength (900 nm). While the height (H) of the SPR dip increased, with the best value of (0.95) at thickness (d=10 nm) and wavelength (700 nm). Also, the sensitivity increased with increasing the bismuth layer thickness at wavelengths (700 , 800,

and 1000 ) nm. The highest obtained sensitivity(S) was (112.5 deg/RIU).

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
Parallel Routing in Wireless Sensor Network
...Show More Authors

The limitations of wireless sensor nodes are power, computational capabilities, and memory. This paper suggests a method to reduce the power consumption by a sensor node. This work is based on the analogy of the routing problem to distribute an electrical field in a physical media with a given density of charges. From this analogy a set of partial differential equations (Poisson's equation) is obtained. A finite difference method is utilized to solve this set numerically. Then a parallel implementation is presented. The parallel implementation is based on domain decomposition, where the original calculation domain is decomposed into several blocks, each of which given to a processing element. All nodes then execute computations in parall

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Performance Improvement for Wireless Sensor Networks
...Show More Authors

In this paper, we prove that our proposed localization algorithm named Improved
Accuracy Distribution localization for wireless sensor networks (IADLoc) [1] is the
best when it is compared with the other localization algorithms by introducing many
cases of studies. The IADLoc is used to minimize the error rate of localization
without any additional cost and minimum energy consumption and also
decentralized implementation. The IADLoc is a range free and also range based
localization algorithm that uses both type of antenna (directional and omnidirectional)
it allows sensors to determine their location based on the region of
intersection (ROI) when the beacon nodes send the information to the sink node and
the la

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Performance Improvement for Wireless Sensor Networks
...Show More Authors

In this paper, we prove that our proposed localization algorithm named Improved
Accuracy Distribution localization for wireless sensor networks (IADLoc) [1] is the
best when it is compared with the other localization algorithms by introducing many
cases of studies. The IADLoc is used to minimize the error rate of localization
without any additional cost and minimum energy consumption and also
decentralized implementation. The IADLoc is a range free and also range based
localization algorithm that uses both type of antenna (directional and omnidirectional)
it allows sensors to determine their location based on the region of
intersection (ROI) when the beacon nodes send the information to the sink node and
the la

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Experimental And Applied Biomedical Research (eabr)
Correlation Between Ultrasound BI-Rads 4 Breast Lesions and Fine Needle Cytology Categories in a Sample of Iraqi Female Patients
...Show More Authors

Breast cancer is the most common malignancy in female and the most registered cause of women’s mortality worldwide. BI-RADS 4 breast lesions are associated with an exceptionally high rate of benign breast pathology and breast cancer, so BI-RADS 4 is subdivided into 4A, 4B and 4C to standardize the risk estimation of breast lesions. The aim of the study: to evaluate the correlation between BI-RADS 4 subdivisions 4A, 4B & 4C and the categories of reporting FNA cytology results. A case series study was conducted in the Oncology Teaching Hospital in Baghdad from September 2018 to September 2019. Included patients had suspicious breast findings and given BI-RADS 4 (4A, 4B, or 4C) in the radiological report accordingly. Fine needle aspirati

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Mar 14 2023
Journal Name
Iraqi Journal Of Science
Synthesis and Characterization of Gold Nanoparticles using 2-(2-methyl-5-amino -1H-imidazol-1-yl) ethanol
...Show More Authors

Gold nanoparticles (Au NPs) have been synthesized via reduction of sodium tetrachloroaurate dihydrate (NaAuCl4.2H2O) with 2-(2-methyl-5-amino -1H-imidazol-1-yl) ethanol (2-MAE) in presence and absence of ascorbic acid as reducing and stabilizing agents. The resulting Au NPs were characterized by UV–Vis spectroscopy, scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray diffraction (XRD), FT-IR spectroscopy. The absorption spectra of gold nanoparticles solutions in the uv-visible and near IR regions were studied at different amine concentrations and pH media.

View Publication Preview PDF
Publication Date
Sat Apr 15 2023
Journal Name
Iraqi Journal Of Science
Synthesis and Characterization of Gold Nanoparticles using 2-(2-methyl-5-amino -1H-imidazol-1-yl) ethanol
...Show More Authors

Gold nanoparticles (Au NPs) have been synthesized via reduction of sodium tetrachloroaurate dihydrate (NaAuCl4.2H2O) with 2-(2-methyl-5-amino -1H-imidazol-1-yl) ethanol (2-MAE) in presence and absence of ascorbic acid as reducing and stabilizing agents. The resulting Au NPs were characterized by UV–Vis spectroscopy, scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray diffraction (XRD), FT-IR spectroscopy. The absorption spectra of gold nanoparticles solutions in the uv-visible and near IR regions were studied at different amine concentrations and pH media.

View Publication Preview PDF
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Assessment of image quality of cervical spine complications using Three Magnetic Resonance Imaging Sequences
...Show More Authors

Examining and comparing the image quality of degenerative cervical spine diseases through the application of three MRI sequences; the Two-Dimension T2 Weighed Turbo Spin Echo (2D T2W TSE), the Three-Dimension T2 Weighted Turbo Spin Echo (3D T2W TSE), and the T2 Turbo Field Echo (T2_TFE). Thirty-three patients who were diagnosed as having degenerative cervical spine diseases were involved in this study. Their age range was 40-60 years old. The images were produced via a 1.5 Tesla MRI device using (2D T2W TSE, 3D T2W TSE, and T2_TFE) sequences in the sagittal plane. The image quality was examined by objective and subjective assessments. The MRI image characteristics of the cervical spines (C4-C5, C5-C6, C6-C7) showed significant difference

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Sep 22 2019
Journal Name
Baghdad Science Journal
Geometry, and Normal Modes of Vibration (3N-6) for Di and Tetra-Rings Layer (6, 0) Linear (Zigzag) SWCNTs; A DFT Treatment
...Show More Authors

            Density Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequ

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of laser energy and pulses on size and concentration of gold nanoparticles in DDDW by LALP method
...Show More Authors

The size and the concentration of the gold nanoparticles (GNPs)
synthesized in double distilled deionized water (DDDW) have been
found to be affected by the laser energy and the number of pulses.
The absorption spectra of the nanoparticles DDDW, and the
surface plasmon resonance (SPR) peaks were measured, and found to
be located between (509 and 524)nm using the UV- Vis
spectrophotometer. SPR calculations, images of transmission
electron microscope, and dynamic light scattering (DLS) method
were used to determine the size of GNPs, which found to be ranged
between (3.5 and 27) nm. The concentrations of GNPs in colloidal
solutions found to be ranged between (37 and 142) ppm, and
measured by atomic absorptio

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Apr 02 2024
Journal Name
Journal Of Engineering
Revolutionizing Depth Sensing: A Review Study of Apple LiDAR Sensor for as-built Scanning Applications
...Show More Authors

Incorporating the LiDAR sensor in the most recent Apple devices represents a substantial development in 3D mapping technology. Meanwhile, Apple's Lidar is still a new sensor. Therefore, this article reviews the potential uses of the Apple Lidar sensor in various fields, including engineering and construction, focusing on indoor and outdoor as-built 3D mapping and cultural heritage conservation. The affordable cost and shorter observation times compared to traditional surveying and other remote sensing techniques make the Apple Lidar an attractive choice among scholars and professionals. This article highlights the need for continued research on the Apple LiDAR sensor technology while discussing its specifications and limitations. A

... Show More
View Publication
Crossref