Preferred Language
Articles
/
ijs-4269
Spectroscopic Analysis of DC-Nitrogen Plasma Produced using Copper Electrodes
...Show More Authors

      This study shows the effects of copper material electrode, applied voltage, and different pressure values on electrical discharge plasma. The purpose of the work is the application of the spectral analysis method to obtain accurate results of nitrogen plasma parameters. By using the optical emission spectroscopy (OES), many N2 molecular spectra peaks appeared in the range from 300 to 480 nm. Also, some additional peaks were recorded, corresponding to atomic and ionic lines for nitrogen, target material, and hydrogen, in all samples. The electron density (ne) was calculated from the measurement of Stark broadening effect, which was found to decrease with increasing pressure from 0.1 mbar to 0.8 mbar. The higher emission intensities occurred at 0.2 mbar working pressure and were reduced with higher pressure. The vibrational temperature (Tvib) for N2 increased from 0.17 to 0.33 eV with increasing the pressure from 0.15 mbar to 0.2 mbar, then decreased to 0.25 eV with increasing the pressure to 0.8 mbar. Other plasma parameters were studied, which are electron temperature (Te), plasma frequency of electron ( ), and Debye length (λD).

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Phytoremediation of Chromium and Copper from Aqueous Solutions Using Hydrilla verticillata
...Show More Authors

The current study included testing the ability of plant Hydrilla verticillata (L. F.) on the accumulation of two heavy metals in its tissues, and use the plant in phytoremediation. The plant was exposure to different concentrations of chromium and copper metals (2.5, 5, 10, 15, 20) ppm, for a period of fourteen days, for each solution.The results showed that Hydrilla was more efficient in the removal of chromium, where the amount of the remaining concentration of chromium at the last day of the experiment was (0.20 ± 0.014- 0.66 ± 0.114- 0.99 ± 0.176- 0.79 ± 0.073- 1.80 ± 0.131) ppm, while for copper was (0.33 ± 0.06- 1.13 ± 0.39- 1.66 ± 0.05- 1.96 ± 0.043- 2.33 ± 0.0497) ppm at the last day of the experiment, respectively.

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Journal Of Science
Influence of Fe2O3 Dust Particles on the Plasma Characteristics of D.C Sputtering System
...Show More Authors

    This work is an experimental study conducted to study the effects of iron oxide dust particles (Fe2O3) on the characteristics of DC discharge plasma in argon gas under vacuum. Electron temperature ( ) and electron density (ne) were calculated by Boltzmann plots and Stark broadening, respectively. The results show that both the electron density and plasma frequency ( ) increased with the operating pressure. While,  and Debye length ( ) decreased with pressure. The glow discharge is more stable with the Fe2O3-dust particles; all dust plasma parameters have lower values  than those of the dust-free plasma.

View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Nov 05 2015
Journal Name
Spectroscopy Europe
Fast and versatile ambient surface analysis by plasmaassisted desorption/ionisation mass spectrometry
...Show More Authors

has experienced a step-change since the inception of ambient mass spectrometry removed the requirement for samples to be investigated under vacuum conditions. Approaches based on surface– plasma interactions are especially promising, including PADI. Whilst the mechanisms involved in generating PADI spectra still need to be unravelled, PADI shows significant promise to become a valuable and versatile tool in the instrumental arsenal available to the surface analyst

Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Experimental investigation of dusty plasma characteristics in AC discharge system
...Show More Authors

In the present work, the effect of size of zinc dust particles on
AC argon discharge characteristics are investigated
experimentally. The plasma characteristics are determined by
using optical emission spectroscopy (OES) techniques. The
results illustrated that the electron temperature (Te) in the present
and absent of Zinc dust particle is reduced with increasing of
pressure. The electron temperature decreases with increasing of
Zinc dust size. Excitation temperature Tex is reduces with
increasing of Ar pressure in present and absent of zinc dust
particles. The present of Zinc dust reduce the Tex of Ar in both
Zinc dust size. The electron density increasing in the present and
absent of both zinc dust siz

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
Evaluations of Potable Water Tanks Epoxy Coatings Performance Using Electrochemical Impedance Spectroscopic Method
...Show More Authors

Abstract  

The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Aug 05 2022
Journal Name
Spectroscopy Europe
Raman spectroscopy analysis for monitoring of chemical composition of aspirin after exposure to plasma flame
...Show More Authors

A Raman spectroscopy method was optimised to examine the chemical changes of aspirin tablets after interaction with helium temperatures. Several aspirin tablets were exposed to plasma-assisted desorption ionisation flame for different times (10, 30, 50, 60, 180 and 300s) and then analysed by Raman spectroscopy using optimal conditions. The changes in chemistry between exposed and fresh (without exposure to plasma) tablets were compared. The vibrational peaks of the aspirin molecule in the Raman spectrum were identified by checking the peak position. The results showed clear spectra with increases in intensity of vibrational peaks until 30s, whereas no spectra were measured for the exposed tablets to plasma flame after 50s. It can, the

... Show More
Preview PDF
Scopus (8)
Scopus
Publication Date
Sun Jul 30 2023
Journal Name
Iraqi Journal Of Science
Development of Low-Temperature Atmospheric Plasma Jet Sources for Biological Applications
...Show More Authors

     The research aims to develop and build a plasma jet system operating under atmospheric pressure.for biological purposes. The advanced plasma system consists of a power supply and a plasma torch. The source of the development of the system is a previous laboratory system that was developed by changing the voltage and frequency of the power supply, as the power provider equips the system with a voltage in the form of a sine wave whose value is fixed at about (7.5kV) peak to peak and its frequency is about (28 kHz). The plasma torch consists of a teflon tube with of width of (10 m ) located at (10mm)  from the end of the tube. The current waveform and voltage wave were measured using a current and voltage sensor and an oscilloscop

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Oct 04 2023
Journal Name
Environmental Progress & Sustainable Energy
Removal of <scp>E133</scp> brilliant blue dye from artificial wastewater by electrocoagulation using cans waste as electrodes
...Show More Authors
Abstract<p>Solid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm<sup>2</sup>), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on </p> ... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Nov 30 2021
Journal Name
Iraqi Journal Of Science
Manufacture a Battery-like Supercapacitors with Electrodes of Graphene
...Show More Authors

A graphene-based battery-like supercapacitors (SC) were manufactured. The prime objective of this research was to use environmentally friendly and natural materials as possible for the SC electrodes, electrolytes and the separators. The SC were designed in cells like batteries, three types of plastic cases were used as SC cells; the electrode and electrolyte materials were mixed together and a solution formed and placed in the designed cell. The electrode material was graphene powder with different weights mixed with different volumes of electrolytes (which were: lemon juice, apple vinegar, H2SO4 and HNO3), and the separators used were Polytetrafluoroethylene polymer (PTFE) and cellulose based parchment paper (PP).
Charging circuit wa

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF