The current research demonstrates the ERI method's effectiveness as a supplementary engineering site investigation approach. Engineering site research is important to indicate the subsoil of proposed production sites. The benefit of the dipole-dipole array for ERI electrical resistivity imaging is that it provides informative records of subsurface geology and condition along with profiles. The dipole-dipole array was performed along with three parallel profiles at the Diyala University site to identify the buried facilities (pipes and cables) in the area. The buried electric cable embedded in a plastic tube was used for simulation to report and verify the field resistivity results. Interpretation of field facts confirmed that the used ERI method was robust in locating buried structures. The dipole-dipole array's strong horizontal sensitivity to subsurface resistivity releases made it possible to provide greater certainty of site characteristics concerning the buried systems. The results were consistent with the information on wells near the work site.
A 5-traverse 2D resistivity survey and 20 Vertical Electrical Sounding (VES) points were carried out on Ile Epo Dump Site with a view to inferring the extent of migration of leachate plumes in the subsurface for possible contamination of groundwater. The surveys were carried out with Omega model resistivity meter. The Schlumberger configuration was employed for the VES while Wenner configuration was employed for the 2D resistivity survey (Constant Separation Techniques). The obtained VES and CST data were interpreted using WinResist and DIPRO respectively. The integrated results revealed three to four geo-electrically polluted materials as highly saturated fills (15 Ωm, 1.9 – 27.4m), saturated fills (15 - 30 Ωm, 3.6 – 29.9m) and un
... Show MoreThis study investigated three aims for the extent of effectiveness of the two systems in educational development of educators. To achieve this, statistical analysis was performed between the two groups that consisted of (26) participants of the electronic teaching method and (38) participants who underwent teaching by the conventional electronic lecture. The results indicated the effectiveness of the “electronic teaching method” and the “electronic lecture method” for learning of the participants in educational development. Also, it indicated the level of equivalence from the aspect of effectiveness of the two methods and at a confidence level of (0.05). This study reached several conclusions, recommendations, and suggestio
... Show MoreThe present study aims to assess environmental pollution using the resistivity method and geological logging technique over a municipal dumpsite of Ijagun Ijebu Ode, underlain by the Afowo Formation within the Dahomey Basin southwestern Nigeria. Forty vertical electrical resistivity soundings stations and six 2D electrical resistivity imaging profiles using Schlumberger and Wenner array respectively with maximum spread-length of 40m at each sounding and profile length of 60 m and 120 m and one borehole log were carried out. Three geoelectrical layers were obtained in the control area, their resistivity values with their corresponding depth of sediment materials is 126 Ωm – 724 Ωm at depth range 0.9 m – 1.1 m (topsoil), 6
... Show MoreThe electrical resistivity method is one of the geophysical methods for detecting weak subsurface zone. The 2D resistivity data were used to compare three electrode configurations, Wenner, Dipole-dipole, and Schlumberger, to detect weak subsurface zones along a profile south of Baghdad near the Bismayah pumping station. The results show many zones of low resistivity that may be weak zones. A dipole-dipole array is a large number of measurements and is more sensitive than others. The Wenner-Schlumberger array has a depth also higher than other arrays. Wenner array has higher signal strength than other arrays. Because it is more sensitive to horizontal and vertical structures, the dipole-dipole array is the optimum for mapping sub
... Show MoreThis study presents the results of atmospheric particulates sampling using high volume air sampler for selected places at Al Tuwaitha nuclear site. The collected samples were analyzed for gross alpha /beta radioactivity using Ludlum model 3030 and measurement particles activity in Al Tuwaitha nuclear site and the surrounding areas for the period from 28/12/2016 to 13/4/2017.The measurement of activity concentrations ranged from (0.42±0.03 to 4.18±0.13) Bq/m3 for alpha particles and from(0.93±0.06 to 9.21±0.26) Bq/m3for beta particles. The activity concentration of nuclides inversely proportional with air temperature and wind speed while humidity is directly proportional with it. Highest value of activity concentration has been found at(
... Show More
Facing industrial companies many pressures and challenges due to rapid changes in the business environment of contemporary, which requires them to do their performance look more inclusive rather than limiting performance evaluation on the financial perspective in spite of its importance, prompting companies to rethink their reality competitive through the adoption of methodologies and new philosophies to manage competitiveness of total quality management, and re-engineering of production processes, and knowledge management,... etc., as This study framework cognitive and practical "to evaluate the performance of a company Diyala General Electric Industries and how to rehabilitate
In the early 90s military operations and United Nations Special Commission “UNSCOM” teams have been destroyed the past Iraqi chemical program. Both operations led an extensive number of scattered remnants of contaminated areas. The quantities of hazardous materials, incomplete destructed materials, and toxic chemicals were sealed in two bunkers. Deficiency of appropriate destruction technology led to spreading the contamination around the storage site. This paper aims to introduce the environmental detection of the contamination in the storage site area using geospatial analysis technique. The environmental contamination level of nutrients and major ions such as sulphate (SO4), potassium (K), sodium (Na), magnesi
... Show MoreThe 2D imaging survey was carried out using Wenner-Schlumberger array through (11) 2D survey lines distributed within and out of Abu-Jir fault zone, Southwest of Karbala City, central Iraq. The aim is to delineate subsurface fractures density. The total length of each 2D survey line is (600m.) with the unit electrode spacing (a) equals to (10m.).The results showed two types of fractures zones. The first type is formed by dissolution process of carbonate rocks, while the second fractures zone is formed from tectonic movements, and it includes two types of fractures system, oblique and vertical fractures.
This study includes comparison between subsurface fracture density within and out of Abu- Jir fault zone. This comparison showed that