The sun which is all energy sources, in today's society, hot water is used for various purposes starting from household to power production. People are adopting various ways to accomplish these goals, such as firewood heat and electrical power, so solar energy is an alternative to the dwindling resources of fossil fuels. Conversion of solar radiation into heat is one of the simplest and most direct applications of this energy, it can be used to heat water systems. A widely used flat-plate solar collector. In this study we have come to heat water using solar energy. This research presents the design and experimental analysis for using Spiral Flow Solar Water Heater (SFSWH) to enhance the thermal efficiency of a flat plate solar collector. Where a solar water heater consists of a copper tube in the shape of a spiral is fixed on an iron flat plate as an absorber. The experiment also includes the selection quality of the paint used to dye the absorbent surface. In May at Fallujah (33.34ºN, 43.8ºE), the thermal performance was calculated. The maximum temperature difference in the storage tank of about 18 ℃ for (SFSWH) during the experimental time was obtained. The efficiency of the collector was obtained is about (80.11%). Where it gives an increase (40 %) in its efficiency compared to published values.
The climate parameters annual rainfall and average mean temperature are investigated from 2000 to 2019 for Kut, Hilla and Iskandaryia. Evidence of climate change is noticed by decreasing the mean annual rainfall and relative humidity with an increase in the annual mean temperature. The climate water balance has been calculated. Due to high temperature, increased evaporation, and low precipitation rates, there was a large water deficit. The total water surplus in the Kut area is 32.86 mm from November to February, and in Hilla and Iskandaryia is 20.4 and 27.8 mm from December to February, respectively. The climate classification for the three stations was semi-dry to dry climates. The region has a significant water deficit of u
... Show MoreAli AL-Gharbi area lies to the northeast of Missan Governorate, southeast of Iraq. The meteorological data recorded in Ali AL-Gharbi station for the period (1994-2014) were used to assess the climatic condition of the study area, it was found that the monthly mean of rainfall is (15.35 mm), relative humidity (43.95 %), the temperature (24.50 C◦), wind speed (4.35 m/sec) and the strongest and most frequent winds are the northwest, sunshine (8.54 h/day) and evaporation (305.73 mm).The results of the data analysis show that, the climate of study area is characterized by dry and relatively hot in summer, and cold with low rain in winter. This study shows that, there is water surplus of (35.69 %) of the total rainfall amount which is equivalen
... Show MoreExcessive intake of fluoride, mainly through drinking water is a serious health hazard affecting humans worldwide. In this study, the defluoridation capacities of locally available raw waste beef bones have been estimated. Several experimental parameters including contact time, pH, bone dose, fluoride initial concentration, bone grains size, agitation rate, and the effect of co-existence of anions in actual samples of wastewater were studied for fluoride removal from aqueous solutions. Results indicated excellent fluoride removal effeciency up to 99.7% at fluoride initial concentration of 10 mg F/L and 120 min contact time. Maximum fluoride uptake was obtained at neutral pH range 6-7. Fluoride removal kinetic was well described by the ps
... Show MoreIn this study, a packed bed was used to remove pathogenic bacteria from synthetic contaminated water. Two types of packing material substrates, sand and zeolite, were used. These substrates were coated with silver nanoparticles (AgNPs), which were prepared by decomposition of Ag ions from AgNO3 solution. The prepared coated packings were characterized using scanning electron microscopy, energy-dispersive X-ray spectroscopy and transmission electron microscopy. The packed column consisted of a PVC cylinder of 2 cm diameter and 20 cm in length. The column was packed with silver nanoparticlecoated substrates (sand or zeolite) at a depth of 10 cm. Four types of bacteria were studied: Escherichia coli, Shigella dysenteriae, Pseudomonas aerugi
... Show MoreThis study appears GIS techniqueand remote sensing data are matching with the field observation to identify the structural features such as fault segments in the urban area such as the Merawa and Shaqlawa Cities. The use of different types of data such as fault systems, drainage patterns (previously mapped), lineament, and lithological contacts with spatial resolution of 30m was combined through a process of integration and index overlay modeling technique for producing the susceptibility map of fault segments in the study area. GIS spatial overlay technique was used to determine the spatial relationships of all the criteria (factors) and subcriteria (classes) within layers (maps) to classify and map the potential ar
... Show More Heat exchanger is an important device in the industry for cooling or heating process. To increase the efficiency of heat exchanger, nanofluids are used to enhance the convective heat . transfer relative to the base fluid. - Al2O3/water nanofluid is used as cold stream in the shell and double concentric tube heat exchanger counter current to the hot stream basis oil. These nanoparticles were of particle size of 40 nm and it was mixed with a base fluid (water) at volume
concentrations of 0.002% and 0.004%. The results showed that each of Nusselt number and overall heat transfer coefficient increased as nanofluid concentrations increased. The pressure drop of nanofluid increased slightly than the base fluid because
Portable and stationary electrical generators became quite popular in Iraq soon after the shortage in national electrical
energy after 2003. Multi step risk assessment process is used in this study in the assessment of risks caused by
contamination of indoor air by lead particles emitted from domestic electrical generators. Two portable electrical
generators are tested under controlled indoor conditions (Radial LG (0.9 keV) fueled with benzene and oil and TigMax
(3 keV), fueled with benzene only). Lead particles in air were sampled by using portable dust sampler (Sniffer, L-30).
The atmospheric particulate sampling process is carried out in a flat located in the first floor of a three stories building
located in Baghdad
Fabrication of solar cell prepared by thermal spray and vacuum thermal evaporation method on silicon wafer(n-type) and studying its efficiency. The film have been deposited on three layers(ZnO then CdS and CdTe) on Si and glass respectively.Direct energy gap was calculated and equal to (4.3,3.4,3)eV and indirect energy gap equal to (3.5,2.5,1.5)eV respectively . Efficiency was calculated for the cell of area 2cm2 it was equal to 0.14%.