The discharged water from tannery plants is main source for pollution of soil and groundwater, especially in Nahrawan area. Water samples is collected from 10 sites of wells, discharged water and from using water in different levels of tannery and 7 soil samples from different sites inside factories area and outside it. The results shown that pH for samples of wells and discharged water were within allowable limits between 6.5- 8.5, except the value of pH recorded in the discharged water sample (after the addition of calcium hydroxide) was 12.8, as well as reached the highest value of total dissolved salts (TDS) 7800 ppm in same samples. It also reached its highest value of electrical conductivity (EC) 8200 μS/cm. The results showed that most samples of discharged water recorded high values of turbidity reached to 557 NTU, while the lowest values recorded in water wells and water sample of Nahrawan village. The samples of discharged water was contained high concentration of relatively heavy elements (Pb and Ni), while not sensing concentration of (Cd and Cr), especially for non-use of chromium in the tanning process because of the lack of economic viability by the owners of the factories. The results of analysis of heavy elements in the soil samples to the concentration of Pb in the samples were all within the limits of Iraqi standard was 50-300 ppm. The results indicated that the highest concentration of Ni recorded in samples of soil in the east and south-eastern tanneries exceeding the Iraqi standard concentration of Ni in the soil the amount of 30-75 ppm, while the concentration of Ni in other soil samples was within the limits of the Iraqi standard, while not sensing by concentration of (Cd and Cr) in these samples.
The main objective of this study is to examine the impact of moisture concrete of clayey soil on the concrete slabs placed directly over it. This experimental study presents the mechanical properties of the concrete slab when placed on different clayey soil moisture content ranging from 0% to the optimum moisture content of 35%. The tests were performed on soil concrete specimens of 25*30*50 mm exposed to sprayed water curing conditions for 28 days. Tests of compressive strength, ultrasonic pulse velocity, crack depth and crack width were investigated through this paper. An ejection relationship between compressive strength of concrete and water content in the soil was observed, with a 26% increase with water increasing from 0% to 35%. T
... Show MoreField trial was conducted in Research Field equipped with rainfall transparent
shade, Biology Department, College of Science, Baghdad University during the
growing season of 2012 to test the potential of sorghum water extract in improving
yield and yield components of local cultivar of mung bean crop grown under
different moisture deficit stresses. The water stresses were applied by irrigated the
plots to field capacity and withheld the next irrigation until the soil water deficit
reaches 80, 50 and 30% of field capacity for control, mild water stress and higher
water stress, respectively. Foliar application of sorghum water extract at 0 ( control),
2.5 and 5% (W/V) was made at preflowering, flowering and fruiting
This study included the Zakhikhah area in the Al- Anbar desert, which it bounded on the north, east, and west by the Euphrates River and on the south by the Ramadi-Qaim road. Several exploratory field trips were taken to the study area. During this time, a semi-detailed area survey was carried out based on satellite imagery captured by American Land sat-7, topographic maps, and natural vegetation variance. All necessary field tools, including a digital camera and GPS device, were brought to determine the soil type and collect plant samples. All of these visits are planned to cover the entire state of Zakhikhah. All vegetation cover observations, identifying sampling sites and attempting to inventory and collect medicinal plants in t
... Show MoreThis study assessed the quality of hand-dug drinking water sources in Eku and its environs at Eku I, Samagidi, Eku 2, and Okuechi, using the weighted arithmetic water quality index method. Water samples collected from hand-dug wells at these locations returned values for analyzed parameters. Temperature 26 – 30(⁰C), dissolved Oxygen (D.O) 5.2-8mg/l, biological oxygen demand (BOD) 5.2-8(mg/l), Electrical Conductivity (EC) 77-119(µS/cm), Total suspended solids were (TSS) 20000-120000(mg/l), pH 5.31-7.09, Phosphates 2-9.2(mg/l), Alkalinity 28-160(mg/l), Turbidity, 0.02 -0.19(NTU) Total coliform 2 -48 (cfu/ml) and fungal count 1-502. Variations in the values of these parameters were only significant for phosphate, alkalinity, and turb
... Show MoreThe research aims to find ways to minimize the use of quantities of chemical fertilizers in agriculture in order to get to an environment that is free of contaminants. Magnetized water technology used in the experience of planting seeds of tomatoes Thomson type to obtain a higher efficiency to absorb fertilizer NRK in the protected environment of the period from February to June. Magnetized water system used locally made levels Gaues (4800,2500,1500) concentrations of 50 to 100% for each level and the rate of (4) replicates, and results indicated that the severity of the magnet (4800 Gaues) and a concentration of 50% gave the highest percentage of tomato fruit size and intensity ( 1500 Gaues) and a concentration of 100% did not give any inc
... Show MoreIn this study a composite materials were prepared containing matrix of polymer blend (Epoxy (EP) 90% + unsaturated polyester (UPS) 10%), (Epoxy (EP) 80% + unsaturated polyester (UPS) 20%), reinforced with Kevlar (K) or, and iron woven (Fe) with one value of volume fraction (30) %. This composite are from: (EP 90%, UPE 10% +K), (EP 90%, UPE 10% +K+Fe), (EP 80%, UPE 20% +K), (EP 80%, UPE 20% +K+Fe). All samples were prepared using hand layup method and then impact test was done in both normal condition and after immersion in tap water for the same period time (eight weeks) also diffusion test was done for period's time (three months). The results showed that had been effected differently after immersion, but specimen (EP80%+UPS20%+K+Fe) ha
... Show MoreThe conductance of solu ti ons of cysteine in water at different concentrations and temperatures has been measured. These solutions obey Onsagcr equation and give linear relations especially at low concentrations. In more concentrated solutions a deviation from the equation is observed.
The molar conductivity of these solutions decreases with t he increase in concen trations at constant temperature.
The values of the ionization constants and the conductivity at infin ite
dilution for each temperature have been calcu lated.
This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated that th
... Show MoreThis research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there
is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated