The discharged water from tannery plants is main source for pollution of soil and groundwater, especially in Nahrawan area. Water samples is collected from 10 sites of wells, discharged water and from using water in different levels of tannery and 7 soil samples from different sites inside factories area and outside it. The results shown that pH for samples of wells and discharged water were within allowable limits between 6.5- 8.5, except the value of pH recorded in the discharged water sample (after the addition of calcium hydroxide) was 12.8, as well as reached the highest value of total dissolved salts (TDS) 7800 ppm in same samples. It also reached its highest value of electrical conductivity (EC) 8200 μS/cm. The results showed that most samples of discharged water recorded high values of turbidity reached to 557 NTU, while the lowest values recorded in water wells and water sample of Nahrawan village. The samples of discharged water was contained high concentration of relatively heavy elements (Pb and Ni), while not sensing concentration of (Cd and Cr), especially for non-use of chromium in the tanning process because of the lack of economic viability by the owners of the factories. The results of analysis of heavy elements in the soil samples to the concentration of Pb in the samples were all within the limits of Iraqi standard was 50-300 ppm. The results indicated that the highest concentration of Ni recorded in samples of soil in the east and south-eastern tanneries exceeding the Iraqi standard concentration of Ni in the soil the amount of 30-75 ppm, while the concentration of Ni in other soil samples was within the limits of the Iraqi standard, while not sensing by concentration of (Cd and Cr) in these samples.
Water injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the
pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves removing the dissolved O2 from w
The current study aims to investigate the effect of strategic knowledge management practices on an excellent performance at the Institution of Industrial Development and Research- the Ministry of Iraqi Industry (IDRMII). The present research is designed according to the descriptive method. To achieve the mentioned research objective, the researchers used the questionnaire as the main data collection tool. The research sample was 150 managers who are working at the top and middle management levels. To analyses the data gathered and reaching the results, several statistical techniques were used within AMOS.V25, SPSS.V21Software, This study reached a set of results, the most important of which is the existence of a positive correlat
... Show MoreOne of the bigger problems in drinking water is disinfection by-products (DBPs) that come from chlorinated disinfection. This study’s goal was to evaluate the drinking water in Al-Yarmouk Teaching Hospital, Ibn Sina Hospital and Ibn-Al-Nafis Hospital. Samples were collected between October 2018 and September 2019. Physical and chemical characteristics of the water were studied, including (temperature, hydrogen ion (pH), total dissolved solids (TDS), electrical conductivity (EC), turbidity, free residual chlorine, total organic carbon (TOC), total trihalomethanes (THMs), total halo acetic acid (THAAs)). Data analysis showed the highest value of study temperatu
... Show MoreHydrogeological investigation and water budget calculation of Koi Sanjaq basin is carried out. This investigation includes the determination of the aquifer types extending through the study area and flow direction as well as aquifer hydraulic properties values. Three main unconfined aquifer types were distinguished , they are (Pilaspi), , (Bihassan-Muqdadiya and Fatha –Injana) Formations , where the flow map of the unconfined aquifers shows that the flow direction is from northern and northeastern parts towards the south and southeastern parts i.e. .Lesser Zab River. Analysis of pumping test data of 9 selected wells from unconfined aquifers show that T values range from 1.51m2/day to 64.4 m2/day revealing the great variations in the aq
... Show MorePhytoplankton, as one of the most important primary producers in aquatic ecosystems, has been widely used to indicate the health of ecosystems. Nine physico-chemical parameters of water, as well as the phytoplankton community, of Al-Chibayish marsh were studied. Samples were collected from four sites and analyzed every two months from January to October 2019.
Seasonal variations in physical and chemical properties were observed at all sites during the study period. The results indicated that 154 species of phytoplankton were recorded. The highest percentage of species was recorded to be 64.28% for Bacillariophyceae (diatoms) (Centrales 3.24% and Pennales 61.03%), followed by Chlorophyceae (16.23%), Cyanophyceae
... Show MoreConcentrations of P137PCs were measured in 40 samples that have been selected from the surface soil in cities of Ramadi, Fallujah, Heet and surrounding areas. The activity of P137PCs in seven dust storms that hit the area western of city of Ramadi within the period 1/3/2013-1/10/2013 was measured also. The concentration in soil ranges between (below detection level-14.5) Bq.kgP-1P, while it ranges between (7.5-8.8) Bq/kg in the dust storms. The dose due to exposure to the cesium in surface soil was estimated to be ranged between (0.4-7.7) *10P-2P mSv.yP-1P while the effective doses due to inhalation of resuspended P137PCs was about 1.61*10P-8P and the doses caused by inhalation of P137PCs in dust storms is ranging between (8.13-9.54)*10P
... Show MoreRaw milk is subjected to various physical, chemical and biological pollutants due to produce, a transporting and marketing processes. The current study was designed to examine raw milk samples which were collected from different locations of Iraq. The highest mean value of Pb content [1.801±0.311 ppm] was recorded while the lowest mean value [0.941±0.104 ppm]. The highest mean value [1.532±0.124 ppm] and gave the lowest mean value [0.063±0.044 ppm] of Cd content. This study has the highest mean value of Cu content was [0.931±0.092 ppm] and but the lowest mean value was [0.308±0.029 ppm]. Metals contents of raw milk in this study showed higher than standards of the International Dairy Federation [IDF].
This study compares the effects of plasma jet and plasma-activated water on teeth root canals contaminated with Escherichia coli bacteria. A plasma jet system was developed for biological purposes that operate at atmospheric pressure. The plasma jet works with argon gas and is generated by a power supply, which supplies a sinusoidal alternating voltage of 12 kV of 20 kHz frequency. The system was optically diagnosed, as it was found that the peaks of the nitrogen spectrum were obtained at the wavelength (300- 450) nm with the appearance of hydroxide peaks at 380 nm. Extracted teeth with one root canal were used, which were contaminated with bacteria and divided into two groups to be treated with a plasma jet and plasma-activated
... Show MoreVarious types of storing tanks are used to store municipal water at homes. This study was carried out to examine several water physical and chemical variables such as pH, EC, TSS and TDS after different storing periods. The obtained results showed no significant differences between the mean of pH values which ranged from 7.27 ± 0.04 in a water sample of galvanized tank after six days of storing to 8.10 ± 0.12 in water sample of aluminum tank after nine storing days. In case of electric conductivity, Highest mean values (1.85±0.09 μS/cm and 1.44 ± 0.21μS/cm) were found in galvanized tank samples for different storing periods while the lowest mean values (0.58±0.06 μS/cm and 1.04±0.06 μS/cm) were recorded in aluminum tank samples
... Show MoreWater pollution is an issue that can be exacerbated by drought as increased concentrations of unwanted substances are a consequence of lower water levels. Polluted water that flows into natural marshlands leads to the deposition of pollutants in the interior of the marsh. Here we present evidence that the interior of the Central Marsh (CM) in southern Iraq suffers from higher levels of pollution than areas closer to the source of water entering the marsh (the Euphrates River). A 1.7m embankment that halts the flow of the Euphrates is only infrequently breached and so the CM is effectively the terminal destination of the waters (and their associated pollutants and agricultural waste) flowing from the West of Iraq.
A range of water
... Show More