Preferred Language
Articles
/
ijs-3646
Detection of Albumin and Urea in Kidney Failure Patients by Optical Biosensor
...Show More Authors

The major function of the kidney is the filtration and secretion of the final products of metabolism and the excess of electrolytes. The term kidney failure denotes inability of the kidneys to perform excretory function leading to retention of nitrogenous waste products from the blood. Biosensor are most accurate, with a rapid diagnosis ,more costly method than the traditional method to avoid any biological changes in blood sample that lead to changes optical characteristic (refractive index and absorption) of blood sample. The current study was designed to single mode  more Sensitivity than multi mode for Biomarkers  were recorded for Albumin 5447.06, 5193.93 and Urea sample 2623.14, 1998.44  in sm and mm respectively .

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Pharmaceutical Negative Results
Gentiopicroside ameliorates lipopolysaccharide-induced acute kidney injury by inhibiting TLR4/NF-κB signaling in mice model
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Apr 01 2007
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Nonsustained Ventricular Tachycardia in Heart Failure
...Show More Authors

Background: Heart failure is a common clinical syndrome with a high morbidity and mortality, despite advances in medical treatment. Death from dangerous ventricular arrhythmias is
frequently implicated.
Patients, materials & methods: Eighty patients with heart failure (HF) (fitting the criteria of heart failure) who were admitted to the medical city teaching hospital during a period of 8
months, were studied for incidence of nonsustained ventricular tachycardia (N.S.V.T.) (detected by Holter monitoring) and its association with the severity of left ventricular dysfunction
(measured by ejection fraction), ventricular size (measured by left ventricular end diastolic dimension), and other factors .
Res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Biochemical And Cellular Archives
Phenotypic and molecular detection of Escherichia coli efflux pumps from UTI patients
...Show More Authors

Scopus (3)
Scopus
Publication Date
Sun Mar 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Histological and Physiological Study of Kidney in Adult Male Albino Mice Mus musculus
...Show More Authors

   The present study aimed to investigate the morphological description and histological structure of kidney in adult albino mice (Mus musculus), The anatomical study revealed that the kidney in albino mice is represented by bean-like shape, smooth with red to brown color, It is situated within the anterior half of abdominal cavity under the diaphragm on both sides of vertebral column. The kidney is covered by capsule of loose connective tissue with mean thickness of (9.6±0.5) micrometer. Histological examination revealed that albino mice kidney tissue differentiated into cortex and medulla, the cortex contains glomeruli with mean diameter of (50.5±1.9) micrometer densely distributed at the peripheral area of the cortex ,

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 27 2019
Journal Name
Iraqi Journal Of Science
Development of Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on Screen-Printed Carbon Electrode Modified With Silver Nanoparticles
...Show More Authors

     The direct electron transfer behavior of hemoglobin that is immobilized onto screen-printed carbon electrode (SPCE) modified with silver nanoparticles (AgNPs) and chitosan (CS) was studied in this work. Cyclic voltametry and spectrophotometry were used to characterize the hemoglobin (Hb) bioconjunction with AgNPs and CS. Results of the modified electrode showed quasi-reversible redox peaks with a formal potential of (-0.245V) versus Ag/AgCl in 0.1M phosphate buffer solution (PBS), pH7, at a scan rate of 0.1Vs-1. The charge transfer coefficient (α) was 0.48 and the apparent electron transfer rate constant (Ks) was 0.47s-1. The electrode was used as a hydrogen peroxide biosensor with a line

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Detection and Diagnosis of Induction Motor Faults by Intelligent Techniques
...Show More Authors

This paper presents a complete design and implementation of a monitoring system for the operation of the three-phase induction motors. This system is built using a personal computer and  two types of sensors (current, vibration) to detect some of the mechanical faults that may occur in the motor. The study and examination of several types of faults including (ball bearing and shaft misalignment faults) have been done through the extraction of fault data by using fast Fourier transform (FFT) technique. Results showed that the motor current signature analysis (MCSA) technique, and measurement of vibration technique have high possibility in the detection and diagnosis of most mechanical faults with high accuracy. Subsequently, diagnosi

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Detection of Bacteriocin Production and Induction by Brassica rapa extract
...Show More Authors

  The present study aimed to try to find natural substances stimulate the production of bacteriocin, as well as "for detection of bacteriocin producing isolates. Two hundred and eighty ( 280)  bacterial isolates, gram negative only, were collected from 760 different pathogenic samples, consist: (Urinary tract infection, septicemia, Vaginal inflammation and diarrhea).  The isolated bacteria are: Escherichia coli, Klebsiella  pneumonia Pseudomonas  aeruginosa,, Salmonella typhi, Enterobacter cloacae, Acinetobacter baumannii, Serratia  liquefaciens, Citrobacter  freundii,  Proteus  mirabilis and Serrattia  odorifera.  Cup assay method was  used to detect bacteriocin production. Loc

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 30 2022
Journal Name
Iraqi Journal Of Science
Optical and Structural Properties of Cobalt Nanoparticles Synthesized by Laser Ablation
...Show More Authors

    Pulsed laser ablation in liquid (PLAL) technique can produce high purity nanoparticles, it is a top-down physical method based on the principle of dividing metal ion bulk precursors into metal atoms, this method was used in this work to synthesis cobalt nanoparticals (CoPNs) with the use of Nd: YAG laser with two wavelengths (355 nm) and (532 nm) at energies (500 mJ) and (600 mJ) respectively, with number of pulses (1000,1100, 1200, 1300, and 1400) for each wavelength. The properties of the prepared nanoparticles were studied by UV-Vis, XRD, SEM with EDX, AFM, and FTIR analysis and then its antibacterial activity was studied by applying it on two types of bacteria with gram-positive (Staphylococcus aureus, Streptococc

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Jan 30 2023
Journal Name
Iraqi Journal Of Science
Characteristics of Lead and Sulfur Plasma Parameters by Optical Emission Spectroscopy
...Show More Authors

This study uses the optical emission spectroscopy (OES) technique to find the lead(Pb) and sulfur (S) plasma parameters employing a pulse of Nd: YAG laser (Q-switched 1064nm wavelength) and different laser energies of (400,500,600 and 700 mJ). The electron temperature Te (eV) is calculated using the Boltzmann-Plot method, and the electron density ne (cm-3)is determined by the Stark broadened way. Moreover, Debye length λD (cm) and plasma frequency ωp (Hz) are studied as a function of laser energy. An apparent increase was noted in the electron temperature of lead plasma and a decrease in sulfur plasma. The results also showed that each increase in the laser intensity causes an incr

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Thu Mar 01 2007
Journal Name
Journal Of Engineering
DEWAXING OF DISTILLATE OIL FRACTION (400- 500 ºC) USING UREA
...Show More Authors

De-waxing of lubricating oil distillate (400-500 ºC) by using urea was investigated in the present study. Lubricating oil distillate produced by vacuum distillation and refined by furfural extraction was taken from Al-Daura refinery. This oil distillate has a pour point of 34 ºC. Two solvents were used to dilute the oil distillate, these are methyl isobutyl ketone and methylene chloride. The operating conditions of the urea adduct formation with n-paraffins in the presence of methyl isobutyl ketone were studied in details, these are solvent to oil volume ratio within the range of 0 to 2, mixer speed 0 to 2000 rpm, urea to wax weight ratio 0 to 6.3, time of adduction 0 to 71 min and temperature 30-70 ºC). Pour point of de-waxed oil and yi

... Show More
View Publication Preview PDF