Preferred Language
Articles
/
ijs-3538
A Modified Advanced Encryption Standard for Color Images
...Show More Authors

     The widespread use of images, especially color images and rapid advancement of computer science, have led to an emphasis on securing these images and defending them against intruders. One of the most popular ways to protect images is to use encryption algorithms that convert data in a way that is not recognized by someone other than the intended user. The Advanced Encryption Standard algorithm (AES) is one of the most protected encryption algorithms. However, due to various types of theoretical and practical assaults, like a statistical attack, differential analysis, and brute force attack, its security is under attack.

In this paper, a modified AES coined as (M-AES) is proposed to improve the efficiency of the AES algorithm by increasing the algorithm's security to make the algorithm more suitable for color image encryption, and make it more resistant to many attacks. The modification is conducted on ShiftRows transformation of the original AES algorithm. To test the efficiency of the proposed M-AES algorithm, several images are drawn from the Signal and Image Processing Institute's (SIPI) image dataset. Moreover, the Mean Square Error (MSE), Peak Signal-to-Noise Ratio (PSNR), Entropy (H), Correlation Coefficient (CC), visual evaluation of histogram, Number of Pixels Change Rate (NPCR) and Unified Average Changing Intensity (UACI) are used as an evaluation metric. The results show that proposed modification to the AES algorithm makes the algorithm more appropriate to image and surpasses the original AES. 

The modification is conducted on ShiftRows step of the original AES algorithm. To test the efficiency of the proposed M-AES algorithm, several images are drawn from the signal and image processing institute's (SIPI) image dataset. Moreover, the mean square error (MSE), peak signal-to-noise ratio (PSNR), entropy (H), correlation coefficient (CC), visual evaluation of histogram, number of pixels change rate (NPCR) and unified average changing intensity (UACI) are used as an evaluation metrics. The results show that the suggested modification to AES makes it's more appropriate to the image and surpasses the original AES.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 14 2021
Journal Name
Iraqi Journal Of Science
A Vehicle ID identification Architecture: A Parallel-Joining WSN Algorithm
...Show More Authors

Several remote sensor network (WSN) tasks require sensor information join. This in-processing Join is configured in parallel sensor hub to save battery power and limit the communication cost. Hence, a parallel join system is proposed for sensor networks. The proposed parallel join algorithm organizes in section-situated databases. A novel join method has been proposed for remote WSNs to limit the aggregate communication cost and enhance execution. This approach depends on two procedures; section-situated databases and parallel join algorithm utilized to store sensor information and speed up processing respectively. A segment arranged databases store information table in segmented shrewd. The Parallel-Joining WSN algorithm is effectively

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Oct 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Robust M Estimate With Cubic Smoothing Splines For Time-Varying Coefficient Model For Balance Longitudinal Data
...Show More Authors

In this research، a comparison has been made between the robust estimators of (M) for the Cubic Smoothing Splines technique، to avoid the problem of abnormality in data or contamination of error، and the traditional estimation method of Cubic Smoothing Splines technique by using two criteria of differentiation which are (MADE، WASE) for different sample sizes and disparity levels to estimate the chronologically different coefficients functions for the balanced longitudinal data which are characterized by observations obtained through (n) from the independent subjects، each one of them is measured repeatedly by group of  specific time points (m)،since the frequent measurements within the subjects are almost connected an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 27 2020
Journal Name
Iraqi Journal Of Science
A Framework of APT Detection Based on Packets Analysis and Host Destination
...Show More Authors

So far, APT (Advanced Persistent Threats) is a constant concern for information security. Despite that, many approaches have been used in order to detect APT attacks, such as change controlling, sandboxing and network traffic analysis. However, success of 100% couldn’t be achieved. Current studies have illustrated that APTs adopt many complex techniques to evade all detection types. This paper describes and analyzes APT problems by analyzing the most common techniques, tools and pathways used by attackers. In addition, it highlights the weaknesses and strengths of the existing security solutions that have been used since the threat was identified in 2006 until 2019. Furthermore, this research proposes a new framework that can be u

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Modern Applied Science
New Combined Technique for Fingerprint Image Enhancement
...Show More Authors

This paper presents a combination of enhancement techniques for fingerprint images affected by different type of noise. These techniques were applied to improve image quality and come up with an acceptable image contrast. The proposed method included five different enhancement techniques: Normalization, Histogram Equalization, Binarization, Skeletonization and Fusion. The Normalization process standardized the pixel intensity which facilitated the processing of subsequent image enhancement stages. Subsequently, the Histogram Equalization technique increased the contrast of the images. Furthermore, the Binarization and Skeletonization techniques were implemented to differentiate between the ridge and valley structures and to obtain one

... Show More
Publication Date
Tue Mar 03 2015
Journal Name
Journal Of Baghdad College Of Dentistry
Periimplantitis-A review
...Show More Authors

Publication Date
Wed Jan 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Periimplantitis- A review
...Show More Authors

This review article concentrates the light about aetiology and treatment of the periimplantitis.

View Publication Preview PDF
Publication Date
Sat Sep 02 2017
Journal Name
Dissertation
Integrating Biophysical and Socio-Economic Approaches to Identify Suitable Policy Incentives for Enhancing Sustainable Water and Land Use (WLI project a case study of Iraq)
...Show More Authors

Preview PDF
Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
THE EFFECT OF EXERCISES USING A MINI SQUASH COURT ON IMPROVING SOME MOTOR ABILITIES AND LEARNING SOME BASIC SKILLS FOR PLAYERS AGED 10-12 YEARS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
THE EFFECT OF EXERCISES USING A MINI SQUASH COURT ON IMPROVING SOME MOTOR ABILITIES AND LEARNING SOME BASIC SKILLS FOR PLAYERS AGED 10-12 YEARS
...Show More Authors

Publication Date
Thu Jan 06 2022
Journal Name
Chemical Papers
A solvent collection technique using dispersive liquid–liquid microextraction coupled with spectrophotometry for the trace determination of folic acid in pure, dosage forms and flaxseed
...Show More Authors

A simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref