Direct FIA methods for estimation of Naringenin (NG) in different samples were proposed. These methods are based on diazotization coupling reactions of two reagents: method (A) p-chloroaniline (PCA) and method (B) procaine hydrochloride (PRH) with NG in basic medium. Yellow dyes with maximum absorption at 416 and 415 nm were formed respectively. Calibration curves were constructed over different NG concentrations, linearity was from 1- 70 and 1- 40 µgmL-1 with detection limits of 0.55 and 0.24 µgmL-1 for (A) and (B) respectively. All analytical variables involved in the FIA procedure were evaluated and optimized. The established methods were successfully applied for the determination of NG in its supplements and urine samples.
A sensitive, accurate, and affordable colorimetric method was developed for assaying prednisolone (PRZ) in various medicinal forms. The procedure involves the oxidation of PRZ by ferric ions, followed by complexation of the resulting ferrous ions with ferricyanide to produce a greenish-blue product. Common complexation conditions were thoroughly investigated. The mole ratio of FeCl₃·6H₂O to K₃Fe(CN)₆ was 8:1. The proposed mechanism of complexation was suggested and considered. Various parameters were optimized, including the reduction of the colorimetric reaction temperature to 50°C and the duration of heating and analysis to 20-30 minutes. The calibration curve was linear over the range of 1-60 µg/mL. The limit of detection (LOD
... Show MoreA new simple and sensitive spectrophotometric method for the determination of trace amount of Co(II) in the ethanol absolute solution have been developed. The method is based on the reaction of Co(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in acid medium of hydrochloric acid (0.1 M) givining maximum absorbance at ((λmax = 656 nm). Beer's law is obeyed over the concentration range (5-60) (μg / ml) with molar absorptivity of (1.5263 × 103 L mol-1 cm-1) and correlation coefficient (0.9995). The precision (RSD% ˂ 1%). The stoichiometry of complex was confirmed by Job's method which indicated the ratio of metal to reagent is (2:1). The studied effect of interference elements Zn(II), Cu(II), Na(I), K(I), Ca(II) and Mg
... Show MoreTwo quantitative, environment-friendly and easily monitored assays for Ni (II) and Co (III) ions analysis in different lipstick samples collected from 500-Iraqi dinars stores located in Baghdad were introduced. The study was based on the reaction of nickel (II) ions with dimethylglyoxime (DMG) reagent and the reaction of cobalt (III) ions with 1-nitroso-2-naphthol (NN) reagent to produce colored products. The color change was measured by spectrophotometric method at 565 nm and 430 nm for Ni and Co, respectively, with linear calibration graphs in the concentration range 0.25-100 mg L-1 (Ni) and 0.5-100 mg L-1 (Co) and LOD and LOQ of 0.11 mg L-1 and 0.36 mg L-1 (Ni), and 0.15 mg L-1 an
... Show MoreA new, Simple, sensitive and accurate spectrophotometric methods have been developed for the determination of sulfanilamide (SNA) drug in pure and in synthetic sample. This method based on the reaction of sulfanilamide (SNA) with 1,2-napthoquinone-4-sulphonic acid (NQS) to form N-alkylamono naphthoquinone by replacement of the sulphonate group of the naphthoquinone sulphonic acid by an amino group. The colored chromogen shows absorption maximum at 455 nm. The optimum conditions of condensation reaction forms were investigated by: (1) univariable method, by optimizing the effect of experimental variables; (different bases, reagent concentration, borax concentration and reaction time), (2) central composite design (CCD) including
... Show MoreTwo different approaches, univariate and multivariate (simplex method), have been used to obtain the optimum conditions for the quantitative Spectrophotometric determination of Eu3+ using Solochrome violet RS (3-Hydroxy-4-(2-hydroxy phenyl azo) naphthalene -1sulfonic acid) (SVRS) as a chromogenic reagent. The investigation shows that Eu3+ ion forms a wine-red complex with SVRS in alkaline buffer solution having a maximum absorbance at 464 nm against reagent blank. Calibration graphs obtained under univariate and simplex were found to be linear in the range of (0.30-8.0) µg/ml with detection limit 0.061µg/ml and molar absorptivity of 9877.66 L/mol.cm and (0.40-10.0)µg/ml with
... Show MoreA new spectrophotometric flow injection method has been establish for the determintaions of some catecholaminedrugs
A sensitive and selective method have been developed for the determination of palladium (II)and platinum (II) . A new reagent and two complexes have been prepared in ethanolic solutions .The method is based on the chelation of metal ions with 4-(4?- pyrazolon azo) resorcinol (APAR) to form intense color soluble products, that are stable and have a maximum absorption at 595 nm and at 463 nm and ?max of 1.11×10 4 and.1.35 ×104 Lmole-1cm-1 for Pd(II) Pt(II) respectively. A linear correlation of (1.4 – 0.2) and (3.2 -0.4 ) ppm for pd(II) pt(II) respectively .The stability constants , relative errors , a relative standard deviations for Pd(II) and Pt(II) were 0.40×105 , 0.4×104 L mol-1 ,0.34 - 0.21% and 2.4 – 0.91% respectively.
... Show MoreThe di-(2-ethylhexyl) phthalate (DEHP) was extracted using different solvents from plastic blood bag. The extracted product was identified using FT-IR, NMR (1H and 13C), DEPT, COSY, HMBC and HSQC_TOCSY spectrometry. The extracted plasticizer was tested in complex formation with Fe2+ and Cr3+ using UV-visible spectrophotometric method. The migration of the plasticizer from the blood bags to the blood was studied and determined during different storage times depending upon the formation of complexes with Fe2+ and Cr3+, and the change in the concentration of Fe2+ and Cr3+.
In this study, the amounts of activity concentrations of naturally occurring in 10 soil samples of the Tigris river and surrounding areas collected from deferent city of Baghdad have been investigated. Tigris river is an important water source for irrigation and drinking in Iraq. This study was done during 2018 in Protection Center of the Iraqi Ministry of Health and Environment using a high purity germanium detector. The resolution of (HPGe) at 2keV and 30% efficiency. The results of soil sample obtained showed that the effective activity concentration of 40K are ranged from 181.4 Bq/kg in sample S6 to 286.4 Bq/kg in S7. For Raeq values are ranged from 6 Bq/m3 in sample S5 to 17 Bq/m3 in sample S3. The obtained data revealed that the me
... Show More