Preferred Language
Articles
/
ijs-3016
Real-time Ultraviolet Radiation Sensor Based on Modified Cladding Optical Fibers Technology
...Show More Authors

      In this work, the performance of single-mode optical fibers (SMFs) for ultraviolet (UV) radiation monitoring and dosimetry applications is presented. In particular, this work will focus on the Radiation-Induced Absorption (RIA) phenomena in the Near-Infrared domain (NIR). Such phenomena play a very important role in the sensing mechanism for SMF. Single mode fibers with a diameter of 50 µm were used for this purpose. These fibers were dipped into germanium (Ge) solution with different concentrations (1, 3, and 5 wt%) to produce the sensing part of the sensor. For all optical fiber sensors under investigation, the results indicated the dependence of the RIA on the applied UV radiation energy. Also, a redshift in peak wavelength was obtained. The influence of Ge concentration on sensing efficiency was studied and the best results were obtained with 3 wt% concentration as compared to 1 wt % and 5 wt % concentrations. The presented sensor shows good sensitivity to UV radiation which makes it possible to be applied in medical applications.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Iraqi Journal Of Physics
Psoriasis Treatment by Using Narrowband-UVB Phototherapy
...Show More Authors

Ultraviolet light radiation is applied to treat Plaque Psoriasis disease by targeted phototherapy. This is available through Narrowband-UVB light radiation devices peaked at wavelength 311 nm. Ten cases were chosen as a study group, 8 males aged 22-40 years old, and 2 females aged 25 and 32 years old who were exposed to ultraviolet light radiation. Their recovery or improvement was followed weekly. Different doses were used according to the severity of the lesion and as a trial for the outcome. The dose was given two times a week, starting with 200mJ/cm2, and subsequently increased by 100 or 200 mJ/cm2 reaching a maximum dose as tolerated by each individual patient. Improvement was observed after 4 – 6 weeks. The

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
An FTIR Study of Characterization of Neat and UV Stabilized Nylon 6,6 Polymer Films
...Show More Authors

  The work is concerned with the characterization of as cast films of neat and UV-stabilized nylon 6,6 by employing FTIR measurements. Band assignment is made for neat and UVstabilized nylon 6,6 using FTIR spectra confirm their molecular structure. UV-stabilizer added to nylon 6,6 has caused reduction in the absorbance of the vibrational bands and thus stabilizes the behavior of the polymer in the end and uses specially in harsh environment.

View Publication Preview PDF
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Preparation of Polyvinyl Alcohol/ Tio2 Nano Fiber by Electrospinning
...Show More Authors

In this research we prepared nanofibers by electrospinning from
poly (Vinyl Alcohol) /TiO2. The spectrum of the solution (Emission)
was studied and found to be at 772 nm, several process parameters
were such as concentration of TiO2 , and the effect of distance from
nozzle tip to the grounded collector (gap distance). The result of the
lower concentration of, the smaller the diameter of nanofiber is.
Increasing the gap distance will affect nanofibers diameter

View Publication Preview PDF
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Automatic Determination of Liquid's Interface in Crude Oil Tank using Capacitive Sensing Techniques
...Show More Authors

The petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Baghdad Science Journal
Study the Structural Properties of Porous Silicon and their Applications as Thermal Sensors
...Show More Authors

The photo-electrochemical etching (PECE) method has been utilized to create pSi samples on n-type silicon wafers (Si). Using the etching time 12 and 22 min while maintaining the other parameters 10 mA/cm2 current density and HF acid at 75% concentration.. The capacitance and resistance variation were studied as the temperature increased and decreased for prepared samples at frequencies 10 and 20 kHz. Using scanning electron microscopy (SEM), the bore width, depth, and porosity % were validated. The formation of porous silicon was confirmed by x-ray diffraction (XRD) patterns, the crystal size was decreased, and photoluminescence (PL) spectra revealed that the emission peaks were centered at 2q of 28.5619° and 28.7644° for et

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 29 2024
Journal Name
Sabrao Journal Of Breeding And Genetics
LOW-‎COST SOIL ‎MOISTURE SENSORS’ ASSESSMENT FOR THEIR ACCURACY AFTER CALIBRATION THROUGH THE ‎GRAVIMETRIC METHOD
...Show More Authors

The existing study aimed to assess four soil moisture sensors’ capacitive (WH51 and SKU: S EN0193) and resistive (Yl69 and IC Station) abilities, which are affordable and medium-priced for their accuracy in six common soil types in the central region of Iraq. The readings’ calibration for the soil moisture sensor devices continued through two gravimetric methods. The first depended on the protocols’ database, while the second was the traditional calibration method. The second method recorded the lowest analysis error compared with the first. The moderate-cost sensor WH51 showed the lowest standard error (SE), MAD , and RMSE and the highest R² in both methods. The performance accuracy of WH51 was close to readings shown by the manufac

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Nov 28 2018
Journal Name
Iraqi Journal Of Science
Using Laser - induced breakdown spectroscopy system to determine the fertility of middle Iraqi soil
...Show More Authors

In this work, different soil samples were brought to study and analyse the element concentrations from different middle regions of Iraq (such as, Habbaniah, Garmah, Fallujah, and Tarmiah cities). Using laser-induced breakdown spectroscopy (LIBS) has been documented as an atomic emission spectroscopy (AES) technique.  Laser-induced plasma utilized to analyse elements in materials (gases, liquids, and solids) in order to analyse elements in materials (gases, liquids and solid). The Nd:YAG laser excitation source at 1064nm with pulse width and pulse duration of 9ns is used to generate power density of 5.5 x 1012 MW/mm2, with optical spectrum in the range 320 -740 nm.

The soils of Habbaniyah and Garmah citi

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 28 2020
Journal Name
Iraqi Journal Of Science
Synthesis and Characterization of Aluminum Doped Zinc Oxide Nanostructures by Nd:YAG Laser in Liquid
...Show More Authors

Aluminum doped zinc oxide nanoparticles (AZO) with different doping concentrations were prepared by Nd-YAG laser ablation of target in deionized water. The characterization of these nanoparticles was performed using Fourier transform infrared (FTIR)  spectroscopy,  scanning electron microscopy (SEM) and photoluminance spectroscopy (PL).  FTIR spectra confirmed the formation  of vibrational bonds for ZnO NPs and AZO NPs. SEM images illustrated that the size and shape of the NPs changed with changing the number of laser pulses. Photoluminescence peaks exhibited two emission peaks, one at the UV region and the second in the visible region, which were modified as the number of laser pulses and doping concentration were ch

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (9)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
Quantum Mechanical Calculations and Electrochemical Study of Vibrational Frequencies, Energies in Some Flavonoids molecules
...Show More Authors

      Quantum mechanical computations is conducted using DFT (Density Functional Theory) and PM3 (Parameterized Model 3), also, using DFT of (B3LYP) with a 6-311++G (d, p) with G09 application. These molecular three components include structure, electronic charge density and energetic characteristics of chosen phytomedicine compounds. The impact of functional groups on physical characteristics were studied using myricetin, linebacker, and flavone because of their chemical structures. For phytomedicine compounds, we utilized quantum mechanical simulations to estimate bond length, energy, vibration(vib.) modes, charge density and mechanical properties (cruelty, strength, stiffness, for the measurements of the lengths and energy of the

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
The Dissolution Study For Sodium Selenite Tablets Using Atomic Absorption Spectrophotometer
...Show More Authors

The development of a meaningful dissolution procedure for drug products with limited water solubility has been a challenge to both the pharmaceutical industry and the agencies that regulate them. Natural surfactants aid in the dissolution and subsequent absorption of drugs with limited aqueous solubility. In vitro, various techniques have been used to achieve adequate dissolution of the sparingly water – soluble or water insoluble drug products such as the use of mechanical methods (i.e., increased agitation and the disintegration method) or hydro alcoholic medium or large volumes of medium. The necessity of assuring the quality of drugs , especially those with low aqueous solubility and in vivo absorption , has led to the development and

... Show More
View Publication Preview PDF
Crossref