This study aims to evaluate the adsorption isotherm of carbon microparticles prepared from pumpkin (Cucurbita maxima) seeds for adsorbing curcumin (as a model of dye). The results were derived and compared using the kinetics approach based on several standard adsorption isotherm models, namely the Langmuir, Temkin, Freundlich, and Dubinin-Radushkevich models. The second aim is to evaluate the effects of carbon particle size (from 100 to 1000 mm) on the adsorption characteristics. The experimental results showed that the adsorption on the surface of carbon microparticles occurred in monolayer with a physical phenomenon. This is because the active areas are located only on the outer surface of carbon and no surface structure in the carbon is available. This is confirmed by the fact that the produced carbon has less porosity and the pores themselves are mostly produced from the release of inorganic contents during carbon synthesis, while the amount of inorganic content is very less. The confirmation of the adsorption profile was also achieved by testing various sizes of carbon microparticles. Smaller particles have direct impacts on the improvement of adsorption capacity, which is due to the existence of a larger surface area, a larger number of adsorption sites, and additional cooperative adsorption, i.e. adsorbate-adsorbate interaction. Understanding the adsorption phenomena occurring on carbon particles is useful for further developments and applications, such as those of catalysts and adsorbents, especially concerning the production of carbon materials from organic waste.
Industrial wastewater containing nickel, lead, and copper can be produced by many industries. The reverse osmosis (RO) membrane technologies are very efficient for the treatment of industrial wastewater containing nickel, lead, and copper ions to reduce water consumption and preserving the environment. Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50 to 200 ppm), pressures (1 to 4 bar), temperatures (10 to 40 oC), pH (2 to 5.5), and flow rates (10 to 40 L/hr), were prepared and subjected to treatment by RO system in the laboratory. The results showed that high removal efficiency of the heavy metals could be achieved by RO process (98.5%, 97.5% and 96% for Ni(II),
... Show MoreThe removal of Anit-Inflammatory drugs, namely; Acetaminophen (ACTP), from wastewater by bulk liquid membrane (BLM) process using Aliquat 336 (QCl) as a carrier was investigated. The effects of several parameters on the extraction efficiency were studied in this research, such as the initial feed phase concentration (10-50) ppm of ACTP, stripping phase (NaCl) concentration (0.3,0.5,0.7 M), temperature (30-50oC), the volume ratio of feed phase to membrane phase (200-400ml/80ml), agitation speed of the feed phase (75-125 rpm), membrane stirring speed (0, 100, 150 rpm), carrier concentration (1, 5, 9 wt%), the pH of feed (2, 4, 6, 8, 10), and solvent type (CCl4 and n-Heptane). The study shows that high ext
... Show MoreBiosorption is an effective method to remove toxic metals from wastewaters. In this
study biosorption of lead and chromium ions from solution was studied using
Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The
experimental results showed that optimum grwoth temperature for both bacteria is 30oC
and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the
optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days
and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria
and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and
Pb for C.freundii, C. kosari and in mixes cultu
The adsorption behavior of methyl orange from aqueous solution on Iraqi bentonite was investigated. The effects of various parameters such as initial concentration of methyl orange, amount of adsorbent, ionic strength and temperature on the adsorption capacity has been studied. The percentage removal of methyl orange increased with the decrease of initial concentration of methyl orange and it increased with the increase of dose of adsorbent. The adsorbed amount of methyl orange decrease with increasing ionic strength and an increase in temperature. The equilibrium adsorption isotherms have been analysed by the linear, Langmuir and Temkin models. The Langmuir isotherms have the highest correlation coefficients. Thermodynamic paramet
... Show MoreThe presence of dyes in wastewater has become a major issue all over the world. The discharge of dyes in the environment is concerned for both toxicological and esthetical reasons. In this study, the removal of dyes from aqueous solution by electrocoagulation using aluminum electrodes as cathode and anode were investigated with the electrocoagulation cell of 1litter. The study included: the impact of various operating parameters on the dyes removal efficiency like pH, NaCl concentration, distance between electrodes, voltage, initial dyes concentration and type of electrodes. The dye (congo red) concentrations were (50, 100, 150, and 200 ppm), stirring speed was 120 rpm at room temperature. pH used was maintained constant
... Show MoreThe degradation and mineralization of 4-chlorophenol (4-CP) by advanced oxidation processes (AOPs) was investigated in this work, using both of UV/H2O2 and photo-Fenton UV/H2O2/Fe+3 systems.The reaction was influenced by the input concentration of H2O2, the amount of the iron catalyst, the type of iron salt, the pH and the concentration of 4-CP. A colored solution of benzoquinon can be observed through the first 5 minutes of irradiation time for UV/H2O2 system when low concentration (0.01mol/L) of H2O2 was used. The colored solution of benzoquinon could also be observed through the first 5 minutes for the UV/H2O2/Fe+3 system at high
concentration (100ppm) of 4-CP. The results have shown that adding Fe+3 to the UV/H2O2 system enhanced
The performance of a batch undivided electrochemical reactor with a rotating cylinder electrode of woven-wire (60 mesh size), stainless steel 316, is examined for the removal of copper from synthetic solution of o.5 M sodium chloride containing 125 ppm at pH ≈ 3.5. The effect of total applied current, rotation speed on the figures of merit of the reactor is analyzed. For an applied current of 300 mA at 100 rpm, the copper concentration decreased from 125 to mg l-1 after 60 min of electrolysis with a specific energy consumption of 1.75 kWh kg-1 and a normalized space velocity of 1.62 h-1. The change in concentration was higher when the total applied currents were increased because of the turbulence
... Show MoreBiosorption is an effective method to remove toxic metals from wastewaters. In this
study biosorption of lead and chromium ions from solution was studied using
Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The
experimental results showed that optimum grwoth temperature for both bacteria is 30oC
and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the
optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days
and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria
and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and
Pb for C.freundii, C. kosari and in mixes cultu
In the present work advanced oxidation process, photo-Fenton (UV/H2O2/Fe+2) system, for the treatment of wastewater contaminated with oil was investigated. The reaction was influenced by the input concentration of hydrogen peroxide H2O2, the initial amount of the iron catalyst Fe+2, pH, temperature and the concentration of oil in the wastewater. The removal efficiency for the system UV/ H2O2/Fe+2 at the optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=3, temperature =30o C) for 1000mg/L load was found to be 72%.