In this study, a new theoretical method for the estimation of absorption and fluorescence spectra is accomplished. These estimations were established following experimental measurements of absorption and fluorescence spectra for the solutions of fluorescein laser dye mixed with titanium dioxide (TiO2) nanoparticles
in distilled water. The used concentration of fluorescein dye was 1x10-5 M, whereas the masses of titanium dioxide nanoparticles were 0.0003g, 0.0005g, 0.001g and 0.002g. An absorption spectra improvement was observed upon raising the mass of TiO2 nanoparticles, which specifies that doping the fluorescein dye with TiO2 nanoparticles have an essential influence on the dye absorption spectra. On the other side, all fluorescence spectra for the dye quenched as TiO2 nanoparticles mass was increased, because of the induced electron transfer. The new method of theoretical estimations was based on curve fitting using Logistic Power Peak (LPP) function to estimate theoretical models for the absorption and fluorescence spectra of these
samples. The results revealed that these estimated models had exceptional matching shapes with the experimental shapes, so that the estimated models can substitute the experimental measurements.
Flexible molecular docking is a computational method of structure-based drug design to evaluate binding interactions between receptor and ligand and identify the ligand conformation within the receptor pocket. Currently, various molecular docking programs are extensively applied; therefore, realizing accuracy and performance of the various docking programs could have a significant value. In this comparative study, the performance and accuracy of three widely used non-commercial docking software (AutoDock Vina, 1-Click Docking, and UCSF DOCK) was evaluated through investigations of the predicted binding affinity and binding conformation of the same set of small molecules (HIV-1 protease inhibitors) and a protein target HIV-1 protease enzy
... Show MoreThe article attempts to provide the theoretical fundamentals for the semiotic component of lacunae in a language. The definitions of the following notions have been represented: 1) lacunarity as a complex phenomenon that works in the modes of language, speech and speech behaviour; 2) lacuna as a gap, an empty space, which lacks something, which may be characteristic of a written work. The author of the article considers the main classes of lacunae, among which are: 1) generic lacunae, which reflect the absence of a common name for a class of objects; 2) species lacunae are the absence of specific names, names of individual types of objects or phenomena; 3) intralingual lacunae are found within the paradigms of one language; 4) interlanguage
... Show MoreIn this paper, the effect of changes in bank deposits on the money supply in Iraq was studied by estimating the error correction model (ECM) for monthly time series data for the period (2010-2015) . The Philips Perron was used to test the stationarity and also we used Engle and Granger to test the cointegration . we used cubic spline and local polynomial estimator to estimate regression function .The result show that local polynomial was better than cubic spline with the first level of cointegration.
This study was achieved to calculate the annual effective dose equivalent (AEDE) in units of (mSv.y-1), and the average radiation dose rate (ADR) in units of (μSv.h-1) which were measured by portable devices. The study was carried out on the workers of the destroyed radiochemistry laboratory located at Al-Twuitha nuclear site (south of Baghdad). Radiation background was determined for comparison with the radioactive dose of soil samples measured with HPGe detector and portable devices type LUDLUM. The radioactivity levels of the area around the radiochemistry laboratory building were within the limits of radiation background. The result showed a significant increase of the annua
... Show MoreThe present work includes a design and characteristics study of a controlling the wavelength of high power diode laser by thermoelectric cooler [TEC] . The work includes the operation of the [TEC] to control the temperature of the diode laser between ( 0- +30) °C by changing the resistance of thermistor. We can control a limited temperature of a diode laser by changing the phase cooling between hot and cold faces of the diode, this process can be attempted by comparator type [LM –311] .The theoretical results give a model for controlling the temperature with, the suitable wavelength.
Chloroquine and Hydroxychloroquine drugs are widely prescribed for malaria disease. Since the end of 2019, humans have been under threat due to a disease called (COVID-19), which was first reported in China. Many methodical approaches have been reported to quantify chloroquine and hydroxychloroquine in blood, urine, plasma, serum, and pharmaceutical dosage form. Some of these techniques are spectrophotometry, liquid chromatography with a mass detector, gas chromatography, and ultra-performance, high-performance liquid chromatography (HPLC), in addition to electrochemical methods. This literature review discusses various analytical methods for the determining hydroxychloroquine and chloroquine.
Density Functional Theory (DFT) calculations were carried out to study the thermal cracking for acenaphthylene molecule to estimate the bond energies for breaking C8b-C5a , C5a-C5 , C5-C4 , and C5-H5 bonds as well as the activation energies. It was found that for C8b-C5a , C5-C4 , and C5-H5 reactions it is often possible to identify one pathway for bond breakage through the singlet or triplet states. The atomic charges , dipole moment and nuclear – nuclear repulsion energy supported the breakage bond .Also, it was found that the activation energy value for C5-H5 bond breakage is lower than that required for C8b-C5a , C5a-C5 , C5-C4 bonds which refer to C5-H5 bond in acenaphthylene molecule are weaker than C8b-C5a , C5a-C5 , C5-C
... Show More