Second harmonic generation (SHG) is a phenomenon observed in nonlinear optics that leads to frequency duplication for a high intensity laser incident on nonlinear crystal using BBO crystal. The SHG yield is achieved when the photons interact with a nonlinear optical material and effectively combine to form new photons with double frequency, and therefore double energy and half wavelength. This paper is concerned with the establishment of an SHG experiment to govern the process of producing half-wavelength laser beam from the input one. The theoretical effort was extended to compute the efficiency by using MATLAB software based on mathematical relationships. The values of the conversion maximum efficiencies, which were computed as a function of the input and output powers of the theoretical computations, were 15.6% and 16% at input and output power values of 0.6 and 0.1, respectively. The experimental results of the laser source of 532nm wavelength (fundamental frequency was 0.563x1015s-1) gave a half wavelength of 266nm (double frequency was 1.126x1015s-1). The conversion efficiencies, computed as a function of the input and output powers of the experimental measurements, were 14.32% and 12.97%, respectively.
In this work a model of a source generating truly random quadrature phase shift keying (QPSK) signal constellation required for quantum key distribution (QKD) system based on BB84 protocol using phase coding is implemented by using the software package OPTISYSTEM9. The randomness of the sequence generated is achieved by building an optical setup based on a weak laser source, beam splitters and single-photon avalanche photodiodes operating in Geiger mode. The random string obtained from the optical setup is used to generate the quadrature phase shift keying signal constellation required for phase coding in quantum key distribution system based on BB84 protocol with a bit rate of 2GHz/s.
The DEM (Digital elevation model) means that the topography of the earth's surface (such as; Terrain relief and ocean floors), can be described mathematically by elevations as functions of three positions either in geographical coordinates, (Lat. Long. System) or in rectangular coordinates systems (X, Y, Z). Therefore, a DEM is an array number that represents spatial distributions of terrain characteristics. In this paper, the contour lines with different interval of high-resolution digital elevation model (1m) for AL-khamisah, The Qar Government was obtained. The altitudes ranging is between 1 m – 8.5 m, so characterized by varying heights within a small spatial region because it represents in multiple spots with flat surfaces.
Oxygen therapy (OT) is considered an essential process for
survival for the i nfants with bronchiolitis > However, it may reach the status of being harmful when using it for along beriod . We , here, attempted to shed a light on relations between oxygen therapy duration(OTD) and each of serum malondialdehyde (MDA) that is used as index for free radical generation , and serum albumin level , in infants with bronchiolitis . Our results confirmed that (OTD) from (1-48) hr. was non effective, while from 49 was very effective where a grave in crease in serum (MDA)level and a decrease in serum albumin concentration were observed during that time . The relation between age a
... Show MoreThe proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit
... Show MoreThe objective of this study was to establish an accurate, precise, sensitive, simple, fast and reliable method for the determination of ciprofloxacin hydrochloride in pure or in pharmaceutical dosage forms using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. The method is based upon the fluorescence fluorescein sodium salt and its quenching by ciprofloxacin hydrochloride in aqueous medium. The solutions of standard and the sample were prepared in distilled water. The calibration graph was linear in the concentration range of using (10 - 100) mMol.L-1 ciprofloxacin hydrochloride (r= 0.9891) with relative standard deviation (RSD%) for 3 mMol.L-1 ciprofloxacin HCl solution is
... Show MoreThis study aimed to investigate the effect of total suspended solids (TSS) on the performance of a continuously operated dual-chamber microbial fuel cell (MFC) proceeded by primary clarifier to treat actual potato chips processing wastewater. The system was also tested in the absence of the primary clarifier and the results demonstrated a significant effect of TSS on the polarization curve of the MFC which was obtained by operating the graphite anodic electrode against Ag/AgCl reference electrode. The maximum observed power and current densities were decreased form 102.42 mW/m2 and 447.26 mA/m2 to 80.16 mW/m2 and 299.10 mA/m2, respectively due to the adverse effect of TSS. Also
... Show More