Preferred Language
Articles
/
ijs-1586
Laser Distance Sensors Evaluation for Geomatics Researches
...Show More Authors

In this study, an approach inspired by a standardized calibration method was used to test a laser distance meter (LDM). A laser distance sensor (LDS) was tested with respect to an LDM and then a statistical indicator explained that the former functions in a similar manner as the latter. Also, regression terms were used to estimate the additive error and scale the correction of the sensors. The specified distance was divided into several parts with percent of longest one and observed using two sensors, left and right. These sensors were evaluated by using the regression between the measured and the reference values. The results were computed using MINITAB 17 package software and excel office package. The accuracy of the results in this work was ± 4.4mm + 50.89 ppm and ± 4.96mm + 99.88 ppm for LDS1 and LDS2, respectively, depending on the LDM accuracy which was computed to the full range (100 m). Using these sensors can be very effective for industrial, 3D modeling purposes, and many other applications, especially that it is inexpensive and available in many versions.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Sensitivity of gold nanoparticles doped in porous silicon
...Show More Authors

In this work gold nanoparticles (AuNPs), were prepared. Chemical method (Seed-Growth) was used to prepare it, then doping AuNPs with porous silicon (PS), used silicon wafer p-type to produce (PS) the processes doping achieved by electrochemical etching, the solution etching consist of HF, ethanol and AuNPs suspension, the result UV-visible absorption for AuNPs suspension showed the single peak located at ~(530 – 521) nm that related to SPR, the single peak is confirmed that the NPs present in the suspension is spherical shape and non-aggregated. X-ray diffraction analysis indicated growth AuNPs with PS. compare the PS layer without AuNPs and with AuNPs doped for electrical properties and sensitivity properties we found AuNPs:PS is more

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Iraqi Journal Of Science
Surface Plasmon Resonance (SPR) Simulation of a Gold-Bismuth Bi-layer Gas Sensor
...Show More Authors

      The features of plasmonic surface frequency sensor technology, such as the small number of sensor samples required, electromagnetic interference, and high sensitivity, have been found to be highly important.. In this paper, a simulation program was created in Matlab_b2018 by adopting Fresnel equations for calculating the reflectivity of the electromagnetic wave between different media. A surface plasmon resonance sensor based on electromagnetic wavelengths within the range (100 nm to 1000 nm) has been proposed. The transfer matrix was used for a system consisting of four different media. The first medium is a semicircular BK7 glass prism, the second medium is a gold layer (40 nm thick), then a bismuth layer of variable thickne

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Monitoring of the Vertical Settlement In Heavy Structures By Precise Levelling
...Show More Authors

Monitoring and analysing of the vertical deformations or the settlements of the structures is one of the main research fields in geodetic applications, which is considered a precise periodic measurement, made at different epochs to investigate these deformations on heavy structures.
In this research, the deformation measurements were carried out on one of Baghdad University buildings,” Building of Computers Department” of dimensions (70.0 * 81.3 m.). Due to some cracks observed in their walls, it was necessary to monitor the vertical displacement of this building at some particular monitoring points by constructing a vertical network and measured in different epochs. The first epoch (zero epoch) was carried out in April 2006, the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Measuring Dyes Concentration Using a Low-Cost Visible-Light Spectrophotometer
...Show More Authors

   A low-cost, RGB LED-based visible-light spectrophotometer was designed to measure dyes concentration. Dyes are widely used as indicators or coloring agents in different applications and knowing their concentration is an essential part for many studies. The proposed spectrophotometer provides many functionalities that clones the traditional expensive spectrophotometers for a budged price under $50. It was aimed to provide a versatile tool for instructors and educators to teach their students the fundamental concepts behind spectrophotometry. Malachite green, methyl red, and methyl orange dyes were chosen to be good samples to show the integrity of the proposed spectrophotometer in terms of accuracy, repeatability, and sensitivity as

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun May 26 2019
Journal Name
Iraqi Journal Of Science
Chloroform Vapor Sensor Based on Air-Gap of the Mach-Zehnder Interferometer
...Show More Authors

The proposal of this study is demonstrating a simple vapor sensor for chloroform (CHCI3) utilitizing air gap region of the Mach-Zehnder interferometer (MZI) by using a single mode optical fiber coupler (3 dB) structure. In the last few decades, flammable liquids such as chloroform have been highly used. This chemical liquid has some degrees of carcinogenic effects in humans in addition to acute and chronic exposure results like blurred vision and nausea.  The two arms of MZI contain a free space gap utilized to serve the sensing mechanism by adding chemical liquid volumes (0.2, 0.4, 0.6, 0.8, and 1) ml and to set the phase difference with air-gap distance 0.5 mm. The small variation in the effective refractive index of ch

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Modified W-LEACH Protocol in Wireless Sensor Network
...Show More Authors

In this paper, a Modified Weighted Low Energy Adaptive Clustering Hierarchy (MW-LEACH) protocol is implemented to improve the Quality of Service (QoS) in Wireless Sensor Network (WSN) with mobile sink node. The Quality of Service is measured in terms of Throughput Ratio (TR), Packet Loss Ratio (PLR) and Energy Consumption (EC). The protocol is implemented based on Python simulation. Simulation Results showed that the proposed protocol provides better Quality of Service in comparison with Weighted Low Energy Cluster Hierarchy (W-LEACH) protocol by 63%.

  

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics
Surface Plasmon Plastic Optical Fiber Resonance with Multi-Layer as Chemical Sensor
...Show More Authors

A chemical optical fiber sensor based on surface plasmon resonance (SPR) was developed and implemented using multimode plastic optical fiber. The sensor is used to detect and measure the refractive index and concentration of various chemical materials (Urea, Ammonia, Formaldehyde and Sulfuric acid) as well as to evaluate the performance parameters such as sensitivity, signal to noise ratio, resolution and figure of merit. It  was noticed that the value of the sensitivity of the optical fiber-based SPR sensor, with 60nm and 10 mm long, Aluminum(Al) and Gold (Au) metals film exposed sensing region, was 4.4 μm, while the SNR was 0.20, figure of merit was 20 and resolution 0.00045. In this work a multimode

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
On Gradient Descent Localization in 3-D Wireless Sensor Networks
...Show More Authors

Localization is an essential demand in wireless sensor networks (WSNs). It relies on several types of measurements. This paper focuses on positioning in 3-D space using time-of-arrival- (TOA-) based distance measurements between the target node and a number of anchor nodes. Central localization is assumed and either RF, acoustic or UWB signals are used for distance measurements. This problem is treated by using iterative gradient descent (GD), and an iterative GD-based algorithm for localization of moving sensors in a WSN has been proposed. To localize a node in 3-D space, at least four anchors are needed. In this work, however, five anchors are used to get better accuracy. In GD localization of a moving sensor, the algo

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 25 2023
Journal Name
Journal Of Legal Sciences
The Principle of Prohibiting the Diversion of the Natural Course of International River Waters
...Show More Authors

The research deals with the principle of the prohibition of international waterway diversion in the law of international watercourses. The research reviews individual and collective doctrinal efforts that have touched upon the principle as an internationally wrongful act because of its serious damage and consequences for downstream States. The research addresses the nature of the principle of the prohibition of diversion of international watercourses; its various effects; principles of international law establishing the principle of prohibition of diversion; and its application in State practice and international justice. This principle has been enshrined in most international treaties and judicial decisions. The principle of prohibition

... Show More
View Publication Preview PDF
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
Parallel Routing in Wireless Sensor Network
...Show More Authors

The limitations of wireless sensor nodes are power, computational capabilities, and memory. This paper suggests a method to reduce the power consumption by a sensor node. This work is based on the analogy of the routing problem to distribute an electrical field in a physical media with a given density of charges. From this analogy a set of partial differential equations (Poisson's equation) is obtained. A finite difference method is utilized to solve this set numerically. Then a parallel implementation is presented. The parallel implementation is based on domain decomposition, where the original calculation domain is decomposed into several blocks, each of which given to a processing element. All nodes then execute computations in parall

... Show More
View Publication Preview PDF
Crossref