Preferred Language
Articles
/
ijs-1586
Laser Distance Sensors Evaluation for Geomatics Researches
...Show More Authors

In this study, an approach inspired by a standardized calibration method was used to test a laser distance meter (LDM). A laser distance sensor (LDS) was tested with respect to an LDM and then a statistical indicator explained that the former functions in a similar manner as the latter. Also, regression terms were used to estimate the additive error and scale the correction of the sensors. The specified distance was divided into several parts with percent of longest one and observed using two sensors, left and right. These sensors were evaluated by using the regression between the measured and the reference values. The results were computed using MINITAB 17 package software and excel office package. The accuracy of the results in this work was ± 4.4mm + 50.89 ppm and ± 4.96mm + 99.88 ppm for LDS1 and LDS2, respectively, depending on the LDM accuracy which was computed to the full range (100 m). Using these sensors can be very effective for industrial, 3D modeling purposes, and many other applications, especially that it is inexpensive and available in many versions.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 29 2018
Journal Name
Journal Of Electronic Materials
Numerical Modeling of 193-nm Excimer Laser Ablation on CR-39 Polymer
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Design and Construction of a Dust Detection System using Infrared Laser: The Case of Dust Storms in Baghdad in the Summer 2022
...Show More Authors

Iraq suffers from serious pollution with harmful particles that have important direct and indirect effects on human activities and human health. In this research, a system for detecting pollutants in the air was designed and manufactured using infrared laser technology. This system was used to detect the presence of pollutants in the dust storms that swept the city of Baghdad which could have a negative impact on human health and living organisms.

The designed detection system based on the use of infrared laser (IR) with a wavelength of 1064 nm was used for the purposes of detecting pollutants based on the scattering of the laser beam from these pollutants. The system was aligned to obtain the best signal for the scattered rays, w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Effects of Q-switched Nd: YAG laser irradiation on the aqueous solution of human albumin and calf-thymus double strand DNA (ctds)
...Show More Authors

Q-switched lasers widely used in management skin diseases and
sometimes its effect may be inadequate or associated with
cytotoxicity. The current study aimed to investigate the effect of
Q-switched Nd:YAG laser upon cellular elements using in vitro
experimental model. Aqueous solutions of human albumin and pure
calf thymus double strand deoxyribonucleic acid (ctdsDNA)
irradiated with Q-switched Nd:YAG laser at different rates (1, 3 Hz)
and time exposure (up to 60 seconds) using 532 nm (400 mJ) and
1064 (1200 mJ) nm wavelength with fixed spot size of 4 mm. The
effect of laser irradiation on the albumin solution also studied in the
presence of elemental salts of copper, zinc and iron.
Q-switched laser irrad

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 12 2025
Journal Name
Al–bahith Al–a'alami
Evaluation of the Iraqi Community for Election Campaigns for Candidates of the House of Representatives and Media Coverage in March 2010: (Cairo as a Model)
...Show More Authors

The elections of the Council of Representatives in Iraq are one of the manifestations of political participation, which makes it attracts the attention of researchers. Where Iraq witnessed in 2005 important political events in the Iraqi arena, a pluralist parliamentary elections or elections in Iraq by direct free election on January 30, the first almost half a century ago. On November 15 of the same year, Iraq adopted a permanent constitution for the country through a popular referendum.

View Publication Preview PDF
Crossref
Publication Date
Sun Apr 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Substrate Temperature Effect on the Structure, Morphological and Optical Properties of CuO/Sapphire Thin Films Prepared by Pulsed Laser deposition
...Show More Authors

This paper addresses the substrate temperature effect on the structure, morphological and optical properties of copper oxide (CuO) thin films deposited by pulsed laser deposition (PLD) method on sapphire substrate of 150nm thickness. The films deposited at two different substrate temperatures (473 and 673)K. The atomic force microscopy (AFM), Fourier transform infrared spectroscopy (FTIR) and UV-VIS transmission spectroscopy were employed to characterize the size, morphology, crystalline structure and optical properties of the prepared thin films. The surface characteristics were studied by using AFM. It is found that as the substrate temperature increases, the grain size increased but the surface roughness decreased.  The FTIR spec

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
The Effect of Laser And Thermal Treatment on the Hardness and Adhesion Force on the Cermet Coating By Thermal Spray Technique
...Show More Authors

Ceramic coating compose from a ceramic mixture (MgO, Al2O3) and metall (Al-Ni) were produced by Thermal Spray Technique. The mixed ratio of used materials Al:Ni (50%) and 40% of Al2O3 and 10% MgO. This mixture was spray on a stainless steel substrate of type (316 L) by using thermal spray with flame method and at spraying distances (8, 12, 16 and 20) cm, then the prepared films were treated by laser and thermal treatment. After that performing a hardness and adhesion tests were eximined. The present study shows that the best value of the thermal treatment is 1000 ℃ for 30 mint; the optimum spray distance is 12 cm and most suitable laser is 500 mJ where the microscopic and mechanical character

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
The Electron Temperature and The Electron Density measurement by Optical Emission Spectroscopy in Laser Produced Aluminum Plasma in Air
...Show More Authors

In this work the Aluminum plasma in Air produced by Nd: YAG pulsed laser, (λ = 1064 nm, τ = 6 ns) has been studied with a repletion rate of 10 Hz. The laser interaction in Al target (99.99%) under air atmosphere generates plasma, which is produced at room temperature; with variation in the energy laser from 600-900 mJ. The electron temperature and the electron density have been determined by optical emission spectroscopy and by assuming a local thermodynamic equilibrium (LTE) of the emitting species. Finally the electron temperature was calculated by the Boltzmann plot from the relative intensities of spectral lines and electron density was calculated by the Stark-broadening of emission line.

View Publication Preview PDF
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
Critical Evaluation of City Streets
...Show More Authors

 The diverse urban spaces of the streets is an important part of the city's physicist configuration and a link between architectural and civilizational communication through time starting from the historic towns down to the contemporary cities, within the proposals of the future cities. From general observations and literature review a research problem is crystallized as some directions not arbitrary rational when expansion and the growth of cities, and other measures wrong or the existence of some incorrect actions and processes related to the cities planning as a categorizing the goals and priorities in city plan.The streets were constitute a high proportion of the total area of cities, where up to over 30% in major cities. These

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Apr 01 2007
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Ultrasound Evaluation of Suspected Appendicitis
...Show More Authors

Background To evaluate the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of ultrasonographic and doppler US findings in the
diagnosis of acute appendicitis.
Method : A total of 115 cases of clinically suspected appendicitis were prospectively examined by grey scale US and doppler US. Five patients were excluded from the study because of
difficulty to perform the graded compression technique. In the other 115 patients who were included in the study population , US appendiceal and periappendiceal signs, as well as doppler US findings were evaluated. Definitive diagnosis was established at surgery and histopathological examination in 62 patients (59

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
British Journal Of Oral And Maxillofacial Surgery
A novel approach for the three-dimensional evaluation of facial asymmetry of unilateral cleft lip and palate patients (UCLP)
...Show More Authors

View Publication
Crossref