Preferred Language
Articles
/
ijs-1426
Evaluation of the Pollution Elements at Samara Water Table – Iraq
...Show More Authors

Underground water is extracted by wells that are connected through underground canals. Thus, the levels of pollutant elements in ground water could be evaluated directly from water samples collected from the wells. This study was conducted in the city of Samara / Salah-Aldeen province – Iraq. The samples were taken from 29
wells within the study area for the period 2012-2014 with a supervision from the General Authority for Groundwater / the Iraqi Ministry of Water Resources. GIS technology was adopted to calculate the pollution elements at Samara water table. The concentrations of chemical elements [K, Na, Mg, Cl, Ca] and compounds [SO4, HCO3] were manipulated and calculated for the entire area. The results of laboratory analyses showed that the groundwater in this area is not suitable for use as drinking water for humans, since the concentrations of the chemical elements and the compounds exceeded the permissible limits and are not in accordance with WHO standards. However, the results also indicated that the groundwater in the covered area is suitable for agriculture irrigation.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat May 14 2022
Journal Name
Oral And Maxillofacial Surgery
Evaluation of crestal sinus floor elevations using versah burs with simultaneous implant placement, at residual bone height ≥ 2.0 _ < 6.0 mm. A prospective clinical study
...Show More Authors

View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Reducing the Water Hardness by Using Electromagnetic Polarization Method
...Show More Authors

Hard water does not pose a threat to human health but may cause precipitation of soap or results stone in the boilers. These reactions are caused by the high concentrations of Ca and Mg. In the industry they are undesirable because of higher fuel consumption for industrial use .Electromagnetic polarization water treatment is a method which can be used for increasing the precipitation of Ca 2+ and CO3 2- ions in hard water to form CaCO3 which leads to decrease the water hardness is research has been conducted by changing the number of coil turns and voltage of the system. The spectroscopy electron microscope was used for imaging the produced crystals. Results of the investigation indicated that

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of some Metal Complexes with (3Z ,5Z, 8Z)-2-azido-8-[azido(3Z,5Z)-2-azido-2,6bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H1,7-dioxa-3,4,5-triazonine – 2,6 – dica
...Show More Authors

  The reaction of LAs-Cl8 : [ (2,2- (1-(3,4-bis(carboxylicdichloromethoxy)-5-oxo-2,5dihydrofuran-2-yl)ethane – 1,2-diyl)bis(2,2-dichloroacetic acid)]with sodium azide in ethanol with drops of distilled water has been investigated . The new product L-AZ :(3Z ,5Z,8Z)-2azido-8-[azido(3Z,5Z)-2-azido-2,6-bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H-1,7-dioxa-3,4,5-triazonine – 2,6 – dicarbonylazide was isolated and characterized by elemental analysis (C.H.N) , 1H-NMR , Mass spectrum and Fourier transform infrared spectrophotometer (FT-IR) . The reaction of the L-AZ withM+n: [ ( VO(II) , Cr(III)  ,Mn(II) , Co(II) , Ni(II) , Cu(II) , Zn(II) , Cd(II) and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Nov 28 2020
Journal Name
Iraqi Journal Of Science
Characteristics of the Oil Water Contact Zone of Nhar Umr and Mishrif Reservoirs in Kumait and Dujaila Oil Fields, Southern Iraq, Using Vp/Vs Ratio and Porosity Logs Data
...Show More Authors

The detailed data of the Vp/Vs ratio and porosity logs were used to detect the Oil-Water Contact Zone (OWCZ) of Nahr Umr sandstone and Mishrif limestone reservoir formations in Kumiat (Kt) and Dujaila (Du) oil fields, southeastern Iraq. The results of OWC were confirmed using P-wave, Resistivity, and Water Saturation (Sw) logs of Kt-1 and Du-1 wells. It was found that the values of the oil-water contact zone thickness in Nahr Umr sandstone and Mishrif limestone were approximately one meter and eight meters, respectively. These results suggest that the OWCZ is possibly thicker in the carbonate rock than clastic rock formations. The thickness of OWCZ in the clastic rocks changed from one part to another, depending on several factors includ

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study of Water Flux through Forward Osmosis Membrane Using Brine\Fresh Water System
...Show More Authors

The present work aims to improve the flux of forward osmosis with the use of Thin Film Composite membrane by reducing the effect of polarization on draw solution (brine solution) side.This study was conducted in two parts. The first is under the effect of polarization in which the flux and the water permeability coefficient (A) were calculated. In the second part of the study the experiments were repeated using a circulating pump at various speeds to make turbulence and reduce the effect of polarization on the brine solution side.
A model capable of predicting water permeability coefficient has been derived, and this is given by the following equations:
Z=Z+C.R.T/9.8(d2/D2+1) [Exp. [-9.8(d

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 05 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
...Show More Authors

In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Oct 28 2019
Journal Name
Iraqi Journal Of Science
Using GIS and Remote Sensing Techniques to Study Water Quality Changes and Spectral Analysis of Tigris River within Mosul City, North of Iraq
...Show More Authors

     The aim of the study is the measuring of changes in the spectral reflectivity water quality, analyzing the seasonal difference of Tigris River within Mosul City in the north of Iraq using Geographic Information Systems (GIS) and remote sensing techniques during the period (2014-2018). For this paper, Satellite images of the 8 Landsat in 2018 for four seasons have been selected in order to study the seasonal changes on the river they took place during 2018.  A total of ten sample datasets were taken at the upstream, midstream and downstream along the Tigris River. This research focuses on analyzing the locational variance of reflectance, analyzing seasonal difference, and finding modeling algal amount change.

... Show More
View Publication Preview PDF
Scopus (8)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials.
Calibration and analysis of the potable water network in the Al-Yarmouk region employing WaterGEMS and GIS
...Show More Authors
Abstract<p>Water supply and distribution networks play an important role in our daily activities. They make a substantial contribution to public health by providing potable water for public consumption and non-potable applications such as firefighters and other purposes such as irrigation. This study used ArcMap 10.8 and WaterGEMS CONNECT Edition update 1 version to create a hydraulic network model to simulate the pipes’ network. Detailed network information, including pipe lengths, layouts, and diameters, was given by the Baghdad Water Department. The TUF-2000H Handheld digital ultrasonic flow meter has been used to measure the water flows in the network’s source nodes. In eight junctions, </p> ... Show More
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Nonlinear Analysis And Applications
Big data analysis by using one covariate at a time multiple testing (Ocmt) method: Early school dropout in iraq
...Show More Authors

Scopus
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Water Resource And Protection
Evaluating Water Stability Indices from Water Treatment Plants in Baghdad City
...Show More Authors

View Publication
Crossref (28)
Crossref