Determination and evaluation of the orbital transition methods between two elliptical earth orbits
...Show More Authors

To transfer a satellite or a spacecraft from a low parking orbit to a geosynchronous  orbit, one of the many transition methods is used. All these methods need to identify some orbital elements of the initial and final orbits as perigee and apogee distances. These methods compete to achieve the transition with minimal consumption of energy, transfer time and mass ratio consumed ), as well as highest accuracy of transition. The ten methods of transition used in this project required designing programs to perform the calculations and comparisons among them.

     The results showed that the evaluation must depend on the initial conditions of the initial orbit and the satellite mechanical exception as well as the target orbit. The most efficient methods of transition in terms of energy required were, sequentially, methods 10, 1, 8, 9, and 2, whereas the least efficient in terms of energy consumption, fuel and  transition time were, sequentially, methods 5,6, and 7. Method 3 was the most efficient when the orbit needed to change the inclination with the transition. The first phase of multi-stage transition is the most energy consuming.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Flow Injection- Spectrophotometric Determination of Salbutamol Sulphate and Pyridoxine Hydrochloride Using 2,4-Dinitrophenylhydrazine
...Show More Authors

A batch and flow injection (FI) methods with spectrophotometric detection is proposed for determining of two of phenolic drugs: salbutamol sulphate(SLB)and pyridoxine hydrochloride(PYD) in pure and in pharmaceutical formulations. The methods utilized an oxidative-coupling reaction based upon oxidation of 2,4-dinitrophenylhydrazine (DNPH) with sodium periodate, where an electrophilic intermediate (diazonium salt of the reagent) is produced, which couples with either SLB or PYD in the presence of sodium hydroxide yielding a highly colored condensation product. The absorbance is measured after 15min at 525and515 nm for SLB and PYD respectively. Calibration graphs for both batch and FIA methods were linear over the concentration ranges of 1-

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Spectrophotometric Determination of Vancomycin Hydrochloride in Pharmaceutical Preparations through Diazotization and Coupling Reactions
...Show More Authors

Two simple, sensitive, accurate and economic methods A and B have been developed for the quantitative estimation of vancomycin hydrochlorid (VHC) and its formulations using another two drug compounds as a coupling reagents.The proposed methods are based on a coupling reaction between VHC and diazotized procain (method A) or diazotized sulphacetamide sodium (method B) in alkaline medium to form intense yellow, water-soluble dyes that are very stable and have a maximum absorption at 447 and 439 nm for methods A and B respectively. Regression analysis of Beer’s law plots showed good correlation in the concentration ranges 1-28 and 1-45 μg ml-1 for methods A and B, respectively with a molar absorbtivity of 4.605×104 L mol-1cm-1 and 4.516

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Solvent Extraction And Spectrophotomteric Determination Of Cu(Ii) With Dicyclohexyl - 18- Crown-6
...Show More Authors

Liquid-Liquid Extraction of Cu(II) ion in aqueous solution by dicyclohexyl-18-crown-6 as extractant in dichloroethane was studied .The extraction efficiency was investigated by a spectrophometric method. The reagent form a coloured complex which has been a quantitatively extracted at pH 6.3. The method obeys Beer`s law over range from (2.5-22.5) ppm with the correlation coefficient of 0.9989. The molar absorptivity the stoichiometry of extracted complex is found to be 1:2. the proposed method is very sensitive and selective.

View Publication Preview PDF
Crossref
Publication Date
Thu May 17 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of Osteocalcin, Bone Alkaline Phosphatase, and Lysyl Oxidase in Iraqi Acromegalic Patients
...Show More Authors

    This study was aimed to determine bone formation markers (OST and BALP) and lysyl oxidase in diabetes and non-diabetes Iraqi acromegaly patients in addition to find the relationship among these parameters. The present study conducted 60 acromegalic patients (30 diabetes & 30 non diabetes) attending National Diabetes Center / AL-Mustansiriya University/Baghdad, and 30 healthy individuals as a control group aged (35-60) years. All patients were administrated Sandostatin drug, and they were diagnosed by physician in the hospital.FBG, GH, IGF-1, OST, BALP, and LOX were determined in all groups. The results showed a highly significant rise in all parameters (GH, IGF-1, FBG, OST, BALP, and LOX values in serum of all pati

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Clonazepam in Pure and Dosage forms using Charge Transfer Reaction
...Show More Authors

A rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine And Public Health
SPECTROPHOTOMETRIC DETERMINATION OF DIPHENHYDRAMINE HCL IN PURE AND PHARMACEUTICAL FORMULATIONS USING THYMOL BLUE
...Show More Authors

This approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo

... Show More
View Publication
Crossref
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Simultaneous Quantitative Determination of Ciprofloxacin and Hydrocortisone by H-Point Standard Addition Method
...Show More Authors

Ciprofloxacin (Cip) and hydrocortisone (Hyd) were simultaneously measured as hydrochloride and sodium succinate, respectively, using the H-point standard addition method (HPSAM). The approach can precisely identify Cip in the presence of Hyd with various analyte-to-interference ratios (5:5, 5:10, 10:5, 10:10) µg.mL-1, in mixed samples containing (1-5µg.ml-1) of Cip, at the wavelengths of (236 and 257) nm. In the same way, Hyd was analyzed in the presence of Cip in different analytes with an interference ratio of (5:5, 5:10, 10:5, 10:10) µg.mL-1, in mixed samples containing (1-5 µg.mL-1) of Hyd, at wavelengths of (266 and 278) nm. The satisfactory results show good reproducibility of the dev

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
Spectrophotometric Determination of Vancomycin Hydrochloride in Pharmaceutical Preparations through Diazotization and Coupling Reactions
...Show More Authors

Two simple, sensitive, accurate and economic methods A and B have been developed for the quantitative estimation of vancomycin hydrochlorid (VHC) and its formulations using another two drug compounds as a coupling reagents.The proposed methods are based on a coupling reaction between VHC and diazotized procain (method A) or diazotized sulphacetamide sodium (method B) in alkaline medium to form intense yellow, water-soluble dyes that are very stable and have a maximum absorption at 447 and 439 nm for methods A and B respectively. Regression analysis of Beer’s law plots showed good correlation in the concentration ranges 1-28 and 1-45 μg ml-1 for methods A and B, respectively with a molar absorbtivity of 4.605×104 L mol-1cm-1 and 4.516

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 01 2014
Journal Name
International Communications In Heat And Mass Transfer
Determination of a time-dependent thermal diffusivity and free boundary in heat conduction
...Show More Authors

View Publication
Scopus (18)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (1)