Preferred Language
Articles
/
ijs-12323
Computer Simulations of Direct Imaging of Extrasolar Planets
...Show More Authors

Numerical simulations are carried out to investigate the possibility of observing
extrasolar planet nearby star via optical telescopes. Several techniques are
considered in this study in order to quantitatively assess their quality in suppressing
the wings of the point spread function of optical telescope of a reference star. The
optical telescope with circular Gaussian shape aperture reveals extrasolar planet
even with contrast ratio 10-7 while the square Gaussian shape aperture reveals the
planet with 10-5.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Simulation of one Dimensional Photoacoustic Imaging
...Show More Authors

The present work provides theoretical investigation of laser photoacoustic one dimensional imaging to detect a blood vessel or tumor embedded within normal tissue. The key task in photoacoustic imaging is to have acoustic signal that help to determine the size and location of the target object inside normal tissue. The analytical simulation used a spherical wave model representing target object (blood vessel or tumor) inside normal tissue. A computer program in MATLAB environment has been written to realize this simulation. This model generates time resolved acoustic wave signal that include both expansion and contraction parts of the wave. The photoacoustic signal from the target object is simulated for a range of laser pulse duration 1

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Journal Of The College Of Education For Women
Impact of Computer on Human Health
...Show More Authors

As computers become part of our everyday life, more and more people are experiencing a
variety of ocular symptoms related to computer use. These include eyestrain, tired eyes, irritation,
redness, blurred vision, and double vision, collectively referred to as computer vision syndrome.
The effect of CVS to the body such as back and shoulder pain, wrist problem and neck pain.
Many risk factors are identified in this paper.
Primary prevention strategies have largely been confined to addressing environmental
exposure to ergonomic risk factors, since to date, no clear cause for this work-related neck pain
has been acknowledged. Today, millions of children use computers on a daily basis. Extensive
viewing of the compute

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 27 2023
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Clinical importance of imaging anatomical signs in predicting transverse sinus dominance using conventional magnetic resonance imaging
...Show More Authors

Background: Differentiating flow gaps associated with hypoplastic transverse sinus from venous thrombosis is a diagnostic challenge in brain magnetic resonance imaging with venography.

Objectives: To assess the clinical benefit of anatomical signs to anticipate the side of the dominant transverse sinus.

Patients and Methods: A total of 100 patients underwent brain magnetic resonance imaging with venography at the radiology department /medical city and were retrospectively reviewed for the direction of superior sagittal sinus flow void, inclination of sulcus for the superior sagittal sinus, angulation of the posterior falx and direction of occipital lobe bending in axial non

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Computer Analysis Of A simplified Eye Model
...Show More Authors

  Computer analysis of simple eye model is performed in the present work by using the Zemax optical design software 2000E . The most important optical parameters of the eye were calculated such as the effective focal length (EFL) , the image spot size at the retina and found to be in a reasonable agreement with the values needed for the laser retinal treatment .The present eye model leads to an effective wavelength and we found the image spot diagram at the surface of the retina and the wavefront error which are provided at zero field angle. This gives a good evidence of the validity of the model in one hand, and can be used to determine the compatibility of any optical design intended for visual applications. By using the pulse fre

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Joubert Syndrome: Imaging Findings and Report of a Case
...Show More Authors

Background: Joubert syndrome (JS) is a very rare autosomal recessive disorder characterized by agenesis of cerebellar vermis, abnormal eye movements, respiratory irregularities, and delayed generalized motor development. Retinal dystrophy and cystic kidneys may also be associated with this clinical syndrome. The importance of recognizing JS is related to the outcome and its potential complications. This syndrome is difficult to diagnose clinically because of its variable phenotype. Its neuroimaging hallmarks include the characteristic molar tooth sign and bat wing-shaped fourth ventricle

View Publication Preview PDF
Publication Date
Mon Feb 20 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Hybrid Algorithm to Protect Computer Networks Based on Human Biometrics and Computer Attributes
...Show More Authors

Objective of this work is the mixing between human biometric characteristics and unique attributes of the computer in order to protect computer networks and resources environments through the development of authentication and authorization techniques. In human biometric side has been studying the best methods and algorithms used, and the conclusion is that the fingerprint is the best, but it has some flaws. Fingerprint algorithm has been improved so that their performance can be adapted to enhance the clarity of the edge of the gully structures of pictures fingerprint, taking into account the evaluation of the direction of the nearby edges and repeat. In the side of the computer features, computer and its components like human have uniqu

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 30 2022
Journal Name
Iraqi Journal Of Science
Direct sum of π-projective semimodules
...Show More Authors

      Let A, and N  are a semiring ,and  a left A- semimodule, respectively. In this work we will discuss two cases: 

  1. The direct summand of π-projective semi module is π-projective, while the direct sum of two π-projective semimodules in general is not π-projective . The details of the proof will be given.
  2. We will give a condition under which the direct sum of two π-projective semi modules is π-projective, as well as we also set conditions under which π-projective semi modules are projective.

View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Jan 02 2006
Journal Name
Journal Of The Faculty Of Medicine Baghdad
is the brain a computer
...Show More Authors

Background:

View Publication Preview PDF
Crossref
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Sampling Period on Process Computer Control
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
The Computational Fluid Dynamic Simulations for Gangrene Disease in Diabetic Foot
...Show More Authors

The diabetic foot is considered one of the long term diabetes complications caused by a defect in blood vessel and nerve system. This requires dealing with diabetic foot with professional medical care, so as to prevent its development in advanced stages which could end to gangrene and amputation of the foot. This study has been initiated through follow-up of twelve patients with diabetes and the presence various occlusions in lower limb artery. One patient from them was chosen for investigation, this patient has stenosis in popliteal artery and presence multiple stenosis in superficial femoral artery. This study based on analysis present case of patient and prediction for progress stenosis in superficial femoral artery till arrive semi t

... Show More
View Publication Preview PDF
Crossref