In this paper, an analytical study for the behavior of ionospheric parameters (Maximum Usable Frequency (MUF) and Optimum Traffic Frequency (FOT)) has been preformed between transmitter station (Baghdad) and many different receiver stations which are distributed randomly over Iraqi territory. The ionospheric parameters dataset has been made using ICEPAC communication model for annual time for the years 2009-2011 of the solar cycle 24. A simplified ionospheric model has been suggested which based on the correlated relationship between the geographical locations coordinates (longitudes & latitudes) of receiver stations and the dataset of the MUF and FOT parameters. The results of this study showed that the correlation between the ionospheric parameters and geographical location coordinates can be expressed as linear surface equation. The predicated ionospheric parameters values using the suggested empirical model show a good fitting with theoretical values that calculated using the international models.
Water saturation is the most significant characteristic for reservoir characterization in order to assess oil reserves; this paper reviewed the concepts and applications of both classic and new approaches to determine water saturation. so, this work guides the reader to realize and distinguish between various strategies to obtain an appropriate water saturation value from electrical logging in both resistivity and dielectric has been studied, and the most well-known models in clean and shaly formation have been demonstrated. The Nuclear Magnetic Resonance in conventional and nonconventional reservoirs has been reviewed and understood as the major feature of this approach to estimate Water Saturation based on T2 distribution. Artific
... Show MoreThe research focuses on determination of best location of high elevated tank using the required head of pump as a measure for this purpose. Five types of network were used to find the effect of the variation in the discharge and the node elevation on the best location. The most weakness point was determined for each network. Preliminary tank locations were chosen for test along the primary pipe with same interval distance. For each location, the water elevation in tank and pump head was calculated at each hour depending on the pump head that required to achieve the minimum pressure at the most weakness point. Then, the sum of pump heads through the day was determined. The results proved that there is a most economical lo
... Show MoreIodide آ in samples آ containing آ magnesium آ fluoride آ was آ determinedآ آ by using iodide selective آ electrode. آ Detecting آ the limit for iodide determination
was around آ 5x1 oآ·5آ آ M with a standard آ deviation آ ranged آ from آ آ± 0.3 to آ± 0.6.
Quantitativeآ آ methodsآ آ including; standard آ additionآ آ method, آ Potentiometric
titration آ by using a Gran plot paper for an equivalent آ point determination and a آ directآ آ methodآ&n
... Show MoreA simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
In this study four cheese samples were randomly collected from local markets. These cheese samples were Ishaqi, Danone, Arab white cheese and Agricultural college cheese.
Results obtained revealed that all these cheese samples were contaminated by fungi in addition to the presence of same heavy metals under study which were Fe, Pb, Ni and Cr. All fungal contaminat were identified which were contaminated them in winter (January). However, fungal pollution in summer was 100% while in winter was 50% Aspergillus niger was polluted chees samples100% in summer while it was 75% in winter. Aspergillus fumigatus was polled cheese samples under study 50% in summer and 0% in winter .Results for heavy metals determination revealed that Fe was con
A simple, sensitive, accurate, and precise spectrophotometric method for the determination of clonazepam (CLNZ) was developed. The method is based on charge transfer reaction between CLNZ and p-Bromanil (p-Br) to form a colored complex. The optimum conditions of complex formation were investigated by (1). Unvariable method, for the optimization of reagent concentration, base concentration, temperature, and time. (2). Multivariable simplex method including the effect of three experimental factors via; reagent concentration, concentration of NaOH and time. The linearity range of CLNZ was (1-30) μg.mL-1 at 378 nm under condition established via simplex method with molar absorptivity (1.9069x104) L.
... Show MoreA reliable differential pulse polarographic (DPP) method has been developed and applied for the determination of ibuprofen IBU in dosage form with dropping mercury electrode (DME) versus Ag/AgCl. The best peak was found at cathodic peak of -1.18 V in phosphate buffer at pH=4 and 0.025M of KNO3 as supporting electrolyte. In order to obtaine the highest sensitivity, instrumental and experimental parameters were examined including the type and concentration of supporting electrolyte, pH of buffer solution, pulse amplitude and voltage step time. Diffusion current showed a direct linear relationship to ibuprofen concentration in the range of (5 – 30) μg. mL-1 (2.43× 10-5
... Show MoreA simple, precise and accurate spectrophotometric method has been developed for simultaneous estimation of sulfanilamide and furosemide in their mixture by using first and second order derivative method in the ultraviolet region. The method depends on first and second derivative spectrophotometry, with zero-crossing and peak to base line and peak area measurements. The first derivative amplitudes at 214, 238 and 266 nm were selected for the assay of sulfanilamide and 240, 260, 284, 314 and 352 nm for furosemide. Peak area at 201222, 222-251 and 251-281 nm selected for estimation of sulfanilamide and at 229-249, 249270, 270-294, 294-333 and 333-382 nm for furosemide. The second derivative amplitudes at 220, 252 and 274 nm for sulfanilamid
... Show More