Preferred Language
Articles
/
ijs-12321
Determination of Ionospheric Parameters over Iraqi Zone
...Show More Authors

In this paper, an analytical study for the behavior of ionospheric parameters (Maximum Usable Frequency (MUF) and Optimum Traffic Frequency (FOT)) has been preformed between transmitter station (Baghdad) and many different receiver stations which are distributed randomly over Iraqi territory. The ionospheric parameters dataset has been made using ICEPAC communication model for annual time for the years 2009-2011 of the solar cycle 24. A simplified ionospheric model has been suggested which based on the correlated relationship between the geographical locations coordinates (longitudes & latitudes) of receiver stations and the dataset of the MUF and FOT parameters. The results of this study showed that the correlation between the ionospheric parameters and geographical location coordinates can be expressed as linear surface equation. The predicated ionospheric parameters values using the suggested empirical model show a good fitting with theoretical values that calculated using the international models.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Proceeding Of The 1st International Conference On Advanced Research In Pure And Applied Science (icarpas2021): Third Annual Conference Of Al-muthanna University/college Of Science
Climate change and its effect on water and vegetation cover over shary region using GIS techniques
...Show More Authors

View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
The Daily Pattern at 500 hPa Geopotential Heights and Its Association with Heavy Rainfall over Iraq
...Show More Authors

    Rainfall in the mid-latitudes is highly related to the synoptic pattern at the upper-levels, this study focuses on the relationship between 500 hPa geopotential height patterns and the cyclone at the surface. Synoptic studies that there is a correlation between cyclone at the surface and deepening of the trough at the upper in the mid-latitudes. The results show that when the upper trough is situated over the eastern Mediterranean, this will enhance the advection of warm and moist air from the tropical region, which will cause baroclinic instability over Iraq, leading to heavy precipitation and torrents in some situations.

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Iraqi Journal Of Physics
A Cut-off low at 500 hPa Geopotential Height and Rainfall Events over Iraq: Case Studies
...Show More Authors

A cut-off low is a closed low with a low value of geopotential height at the upper atmospheric levels that has been fully detached (cut-off) from the westerly flow and move independently. A cut-off low causes extreme rainfall events in the mid-latitudes regions. The main aim of this paper is to investigate the cut-off low at 500 hPa over Iraq from a synoptic point of view and the behavior of geopotential height at 500 hPa. To examine the association of the cut-off low at 500 hPa with rainfall events across Iraq, two case studies of heavy rainfall events from different times were conducted. The results showed that the cut-off low at 500 hPa with a low value of geopotential height will strengthen the low-pressure system at the surface, lea

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Iraqi Journal Of Science
Irregular urban Expansion and Its Effects on Air Temperature over Baghdad City using Remote Sensing Technique
...Show More Authors

Heat island is known as the increases in air temperature through large and industrial cities compared to surrounding rural areas. In this study, remote sensing technology is used to monitor and track thermal variations within the city center of Baghdad through Landsat satellite images and for the period from 2000 to 2015. Several processors and treatments were applied on these images using GIS 10.6 and ERDAS 2014, such as image correction and extraction, supervised classification, and selection of training samples. Urban areas detection was resulted from the supervised classification linked to the temperature readings of the surface taken from the thermal bands of satellite images. The results showed that the surface temperature of the c

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Seasonal variation and correlation between the physical, chemical and microbiological parameters of Nile water in selected area in Egypt (Case study): physical, chemical and microbiological parameters of Nile water
...Show More Authors

Fresh water resources in terms of water quality is a crucial issue worldwide. In Egypt, the Nile River is the main source of fresh water in the country and monitoring its water quality is a major task on governments and research levels. In the present case study, the physical, chemical and algal distribution in Nile River was monitored over two seasons (winter and summer) in 2019. The aims of the study were to check the seasonal variation among the different water parameters and also to check the correlations between those parameters. Water samples were collected from the Nile in Cairo governorate in EGYPT. The different physiochemical and microbiological properties in water samples were assessed. The studied parameters were included: te

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Double probe for measuring the plasma parameters
...Show More Authors

In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing

... Show More
View Publication Preview PDF
Publication Date
Sun May 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Astudy About Some Physiological Parameters In Smokers
...Show More Authors

          Smoking has been accepted as a risk factor for many chronic diseases, including cardiovascular diseases, respiratory diseases, cancer, ulcers and osteoporosis. Tobacco smoke contains many oxidants and free radicals that can cause damage to lipids, proteins, DNA, carbohydrates and other biomolecules. In vivo, antioxidant nutrients which include vitamin C, selenium (Se), zinc (Zn) and copper (Cu) play a crucial role in defending against oxidant damage. The present study was designed to investigate the influence of cigarette smoking on serum  Zn, Cu ,PCV,W.B.Cs., and BMI. Eighty healthy men (40 smokers and 40 non-smokers) from Baghdad, the capital of Iraq, volunteered to p

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 22 2024
Journal Name
Journal Of Engineering
Correction Procedure for the Determination of Soil Specific Surface
...Show More Authors

View Publication
Publication Date
Sun Dec 22 2024
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Radiation Research And Applied Sciences
Determination of muon absorption coefficients in heavy metal elements
...Show More Authors

View Publication
Crossref (2)
Clarivate Crossref