Different concentrations prepared 2,4,8,16,32 ppt from flow water to Shatt-Alarab
by adding Chlorella vulgares and Navicual busiedtii as alone for each
concentration. The results showed that the concentrations of salinity reduced to 0,
1.78, 9.45, 15 ppt after 10 days, with removed percentage 100, 100, 77.75, 40.93,
37.12 % respectively for Chlorella vulgares the cell numbers of Chlorella vulgares
reached to 58.123, 60.123, 69.712, 37.234, 30.546 ×104/ml comparing with the
control 55.652 ×104/ml while the absorbability of salinity reached to 0.378, 0.391,
0.489, 0.231, and 0.192 nm comparing with 0.342 as control. The external cell wall
of Chlorella vulgares was swelling at 32 ppt. the removal percentage of salinity
reached to 100, 100, 75 , 66, 45 % for Navicual busiedtii with cell numbers reached
to 97.113, 120.903, 178.024, 231.112, 77.132 ×104/ml respectively comparing with
91.362 ×104/ml as control, while the absorbability of salinity ranched to 0.354,
0.367, 0.484 and 0.123 nm without change at cell wall of Navicual busiedtii.
Background: One of the drawbacks of vital teeth bleaching is color stability. The aim of the present study was to evaluate the effects of tea and tomato sauce on the color stability of bleached enamel in association with the application of MI Paste Plus (CPP-ACPF). Materials and Methods: Sixty enamel samples were bleached with 10% carbamide peroxide for two weeks then divided into three groups (A, B and C) of 20 samples each. After bleaching, the samples of each group were subdivided into two subgroups (n=10). While subgroups A1, B1 and C1 were kept in distilled water, A2, B2, and C2 were treated with MI Paste Plus. Then, the samples were immersed in different solutions as follow: A1 and A2 in distilled water (control); B1 and B2 in black
... Show MoreA sensitivity-turbidimetric method at (0-180o) was used for detn. of mebeverine in drugs by two solar cell and six source with C.F.I.A.. The method was based on the formation of ion pair for the pinkish banana color precipitate by the reaction of Mebeverine hydrochloride with Phosphotungstic acid. Turbidity was measured via the reflection of incident light that collides on the surface particles of precipitated at 0-180o. All variables were optimized. The linearity ranged of Mebeverine hydrochloride was 0.05-12.5mmol.L-1, the L.D. (S/N= 3)(3SB) was 521.92 ng/sample depending on dilution for the minimum concentration , with correlation coefficient r = 0.9966while was R.S.D%
... Show MoreFive
In a survey of the crabronid fauna of Iraq during June to October 2022; 9species belonging to the genus
One hundred Ninty two s mples were collected from (Cooling towers) between the period 1 /l/2004-13/12/2005. The Results Rev a)ecL that physical and chemic:a) analysefor watr samples including Tempera re,, pH and cWodde concentration ranges were f01:md
... Show MoreThis paper is concerned with the numerical solutions of the vorticity transport equation (VTE) in two-dimensional space with homogenous Dirichlet boundary conditions. Namely, for this problem, the Crank-Nicolson finite difference equation is derived. In addition, the consistency and stability of the Crank-Nicolson method are studied. Moreover, a numerical experiment is considered to study the convergence of the Crank-Nicolson scheme and to visualize the discrete graphs for the vorticity and stream functions. The analytical result shows that the proposed scheme is consistent, whereas the numerical results show that the solutions are stable with small space-steps and at any time levels.
Echocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.
Abstract
A two electrode immersion electrostatic lens used in the design
of an electron gun, with small aberration, has been designed using
the finite element method (FEM). By choosing the appropriate
geometrical shape of there electrodes the potential V(r,z) and the
axial potential distribution have been computed using the FEM to
solve Laplace's equation.
The trajectory of the electron beam and the optical properties of
this lens combination of electrodes have been computed under
different magnification conditions (Zero and infinite magnification
conditions) from studying the properties of the designed electron
gun can be supplied with Abeam current of 5.7*10-6 A , electron
gun with half acceptance