A batch and flow injection (FI) methods with spectrophotometric detection is proposed for determining of two of phenolic drugs: salbutamol sulphate(SLB)and pyridoxine hydrochloride(PYD) in pure and in pharmaceutical formulations. The methods utilized an oxidative-coupling reaction based upon oxidation of 2,4-dinitrophenylhydrazine (DNPH) with sodium periodate, where an electrophilic intermediate (diazonium salt of the reagent) is produced, which couples with either SLB or PYD in the presence of sodium hydroxide yielding a highly colored condensation product. The absorbance is measured after 15min at 525and515 nm for SLB and PYD respectively. Calibration graphs for both batch and FIA methods were linear over the concentration ranges of 1-24μg/ml for SLB and 0.4-16μg/ml for PYD, and of 30-1100μg/ml for SLB and20-1200μg/ml for PYD respectively. A detection limits of 0.580μg/ml SLB and 0.150μg/ml PYD for batch method, and 15.32μg/ml SLB and12.21μg/ml PYD for FIA method. The proposed methods were applied successfully to the determination of SLB and PYD in pharmaceutical preparations and were compared statistically with reference methods by means of t- test and F- test and were found not to differ significantly at 95% confidence level. The procedures are characterized by its simplicity, accuracy and precision. The results obtained were in good agreement with those obtained using reference methods for comparison.
Zinc oxide (ZnO) transparent thin films with different oxygen flow rates (0.5, 1.0, and 1.5)Litter/min. were prepared by thermal evaporation technique on glass substrate at a temperature of 200℃ with rate (10±2)nm sec-1, The crystallinity and structure of these films were analyzed by X-ray diffraction (XRD). It exhibits a polycrystalline hexagonal wurtzite structure and the preferred orientation along (002) plane. The Optical properties of ZnO were determined through the optical transmission method using ulta violet–Visible spectrophotometer with in wave length (300-1100)nm. The optical transmittance of the ZnO films increases from 75% to 85% with increase flow rate of O2, and the optical band gap of ZnO
... Show MoreBackground: Endoscopic treatment is widely accepted as the most effective method for controlling acute ulcer bleeding and preventing ulcer rebleeding.
Objective: is to compare efficacy and safety of local endoscopic injection of adrenaline to normal saline in bleeding peptic ulcers and to identify the risk of rebleeding after successful endoscopic hemostasis.
Patients and methods: This is a prospective study of 77 patients with bleeding peptic ulcers were treated by local endoscopic injection of adrenaline or NS. Patients who succeeded initial hemostasis were admitted and followed for rebleeding events. Rebleeding was confirmed by urgent endoscopy followed by referral to urgent surgery. Outcome was mea
Background: Anti-vascular endothelial growth factors commonly used intravitreally for treatment of variable retinal disease worldwide, which help to regulate the upregulation of vascular endothelial growth factors due to ischemia or/and other retinal insult.
Objective: To review all cases of intravitreal bevacizumab given in the retinal unit of the Eye Specialty Private Hospital in Iraq from December 2015 to June 2016, pointing out the common indications.
Methods: A retrospective study including all cases of intravitreal injections of bevacizumab recorded at the Eye Specialty Private Hospital from December 2015 to June 2016 were retrieved. Age, sex, laterality, diagnosis
... Show MoreAbstract
Heavy-duty diesel vehicle idling consumes fossil fuel and reduces atmospheric quality at idle period, but its restriction cannot simply be proscribed. A comprehensive tailpipe emissions database to describe idling impacts is not yet available. This paper presents a substantial data set that incorporates results from DI multi-cylinders Fiat diesel engine. Idle emissions of CO, hydrocarbon (HC), oxides of nitrogen (NOx), smoke opacity, carbon dioxide (CO2) and noise have been reported, when three EGR ratios (10, 20 and 30%) were added to suction manifold.
CO2 concentrations increased with increasing idle time and engine idle speed, but it didn’t show clear effect for IT adva
... Show MoreIn this paper, the rotation curve of the Milky Way galaxy has been determined using the observed HI emission line at a wavelength of 21 cm. Particularly, the Tangent Point Method was used in order to measure the rotational velocity and the distance to the center of the Milky Way. The measured rotation curve showed that the rotational velocity remains approximately constant at large distances from the center of the Galaxy. This is actually an evidence for the existence of dark matter in the halo of the Milky Way. If all the matter in the Milky Way is visible, then the behavior of the rotation curve of the galaxy should experience a Keplerian decline. The mass of the Milky Way within a radius of 15 kpc was also estimated to be ~ 1.65 × 10
... Show MoreThis study aims to assess the formation evaluation of the Jeribe Formation in Hamrin oilfield. The present study involved four selected wells of (Early- Mid Miocene) Jeribe Formation in Hamrin structure-Allas field; HR-2, HR-8, HR-9, and HR-16 located North of Iraq. The work deals with the available data that includes the most required information to improve such studies. Techlog Software V.2015 was used to carry out a reliable calculation of petrophysical properties utilizing conventional logs to determine the reservoir characteristics (lithology, porosity, and saturation). The computed CPI (software resulted) based on log information divided the Jeribe reservoir into two reservoir units (Jr-1 and Jr
... Show MoreA new, simple, accurate, fast and sensitive spectrophotometric method has been
developed for the analysis of Pyrocatechol, Resorcinol, and pyrogallolin pure
commercial samples by continuous flow injection analysis. The method was based on
the oxidation of the organic compounds with Ce(IV)sulfate in acidic medium to
formed a brown colored species which determined using homemade Ayah 3SBGR x3-
3D solar cell flow injection microphotometer. Optimum conditions were obtained
using a high intensity green light emitted diode as an irradiation source
forPyrocatechol, Resorcinol, whileblue light emitted diode as an irradiation source for
pyrogallol. The linear dynamic range for the instrument response versus Pyrocatechol,
A load flow program is developed using MATLAB and based on the Newton–Raphson method,which shows very fast and efficient rate of convergence as well as computationally the proposed method is very efficient and it requires less computer memory through the use of sparsing method and other methods in programming to accelerate the run speed to be near the real time.
The designed program computes the voltage magnitudes and phase angles at each bus of the network under steady–state operating conditions. It also computes the power flow and power losses for all equipment, including transformers and transmission lines taking into consideration the effects of off–nominal, tap and phase shift transformers, generators, shunt capacitors, sh
The flow in a manifolds considered as an advanced problem in hydraulic engineering applications. The objectives of this study are to determine; the uniformity qn/q1 (ratio of the discharge at last outlet, qn to the discharge at first outlet, q1) and total head losses of the flow along straight and rectangular loop manifolds with different flow conditions. The straight pipes were with 18 m and 19 m long and with of 25.4 mm (1.0 in) in diameter each. While, the rectangular close loop configuration was with length of 19 m and with diameter of 25.4 mm (1.0 in) also. Constant head in the supply tank was used and the head is 2.10 m. It is found that outlets spacing and manifold configuration are the main factors aff
... Show More