A batch and flow injection (FI) methods with spectrophotometric detection is proposed for determining of two of phenolic drugs: salbutamol sulphate(SLB)and pyridoxine hydrochloride(PYD) in pure and in pharmaceutical formulations. The methods utilized an oxidative-coupling reaction based upon oxidation of 2,4-dinitrophenylhydrazine (DNPH) with sodium periodate, where an electrophilic intermediate (diazonium salt of the reagent) is produced, which couples with either SLB or PYD in the presence of sodium hydroxide yielding a highly colored condensation product. The absorbance is measured after 15min at 525and515 nm for SLB and PYD respectively. Calibration graphs for both batch and FIA methods were linear over the concentration ranges of 1-24μg/ml for SLB and 0.4-16μg/ml for PYD, and of 30-1100μg/ml for SLB and20-1200μg/ml for PYD respectively. A detection limits of 0.580μg/ml SLB and 0.150μg/ml PYD for batch method, and 15.32μg/ml SLB and12.21μg/ml PYD for FIA method. The proposed methods were applied successfully to the determination of SLB and PYD in pharmaceutical preparations and were compared statistically with reference methods by means of t- test and F- test and were found not to differ significantly at 95% confidence level. The procedures are characterized by its simplicity, accuracy and precision. The results obtained were in good agreement with those obtained using reference methods for comparison.
This paper proposes a new approach to model and analyze erect posture, based on a spherical inverted pendulum which is used to mimic the body posture. The pendulum oscillates in two directions, [Formula: see text] and [Formula: see text], from which the mathematical model was derived and two torque components in oscillation directions were introduced. They are estimated using stabilometric data acquired by a foot pressure mapping system. The model was quantitatively investigated using data from 19 participants, who were first were classified into three groups, according to the foot arch-index. Stabilometric data were then collected and fed into the model to estimate the torque’s components. The components were statistically proce
... Show MoreThis research presents a new study in reactive distillation by adopting a consecutive reaction . The adopted consecutive reaction was the saponification reaction of diethyl adipate with NaOH solution. The saponification reaction occurs in two steps. The distillation process had the role of withdrawing the intermediate product i.e. monoethyl adipate from the reacting mixture before the second conversion to disodium adipate occurred. It was found that monoethyl adipate appeared successfully in the distillate liquid. The percentage conversion from di-ester to monoester was greatly enhanced (reaching 86%) relative to only 15.3% for the case of reaction without distillation .This means 5 times enhancement . The presence of two layers in both the
... Show MoreThis research presents a new study in reactive distillation by adopting a consecutive reaction . The adopted consecutive reaction was the saponification reaction of diethyl adipate with NaOH solution. The saponification reaction occurs in two steps. The distillation process had the role of withdrawing the intermediate product i.e. monoethyl adipate from the reacting mixture before the second conversion to disodium adipate occurred. It was found that monoethyl adipate appeared successfully in the distillate liquid. The percentage conversion from di-ester to monoester was greatly enhanced (reaching 86%) relative to only 15.3% for the case of reaction without distillation .This means 5 times enhancement . The presence of two layers in both
... Show MoreMetronidazole-MIPs were prepared by using (MDZ) as the template as well as allylchloride (AYC) or allylbromide (AYB) as monomer, used (TMPTA) tri-methylol propane tri-acrylate or ethylene glycol di-methyl acrylate (EGDMA) as cross-linker and initiator used (BP) benzyl peroxide. By using different plasticizers (di butyl Phthalate (DBPH), Nitrobenzene (NB), oleic acid (OA) and paraffin) for MDZ-MIP1 and (Di-butyl sebecate (DBS), Di-methyl acrylate (DMA), Tributylphosphate(TBP) and Tris(ethylhexyl phosphate (TEHP) ) for MDZ-MIP2. Membranes of MIPs were prepared in PVC matrix. The characterizations of each electrode were determined The Slope range from (55.083 - 43.711) mV/decade, Limit of Detection (8 X 10 -4- 2 X 10-6) and Linearity
... Show MoreIn this article our goal is mixing ARMA models with EGARCH models and composing a mixed model ARMA(R,M)-EGARCH(Q,P) with two steps, the first step includes modeling the data series by using EGARCH model alone interspersed with steps of detecting the heteroscedasticity effect and estimating the model's parameters and check the adequacy of the model. Also we are predicting the conditional variance and verifying it's convergence to the unconditional variance value. The second step includes mixing ARMA with EGARCH and using the mixed (composite) model in modeling time series data and predict future values then asses the prediction ability of the proposed model by using prediction error criterions.
Pera Magroon anticline is located within the northeastern of Iraq, covering area estimated by 958 Km2. The Landsat ETM+ false color composite imagery was produced by assigning [741] bands. It is used to distinguish alluvial fans in the southwestern limb of Pera Magroon anticline. Digital elevation models (DEM) were used for describing topographic features related to the alluvial fans, as well as, three dominations model (3D) was created from (DEM) and the Landsat ETM+ image.
Arc GIS, hydro tool set was used to draw the drainage patterns, the area of study was covered by dendritic and parallel patterns. Contour lines across the fans form segments of ellipses reveal the pattern of tectonic act
... Show More