Preferred Language
Articles
/
ijs-11937
Immunohistochemical Study of Estrogen, Progesterone Receptor and Her-2neu Oncogene with Her-2neu Biomarker Estimation by ELISA Technique in Primary Breast Cancer before Chemical Therapy
...Show More Authors

Breast cancer is one of the comments malignant tumors worldwide especially in Iraq; it is a leading cause of death in Iraqi women. Determination of estrogen and progesterone receptors status is helpful in selecting the patients most likely to receive benefit from endocrine therapy, and provide prognostic information on recurrence and survival since their expression is related to the degree of the tumor differentiation. From November 2012 to March 2013, 150 breast cancer patients at Al-Amal Hospital in Baghdad were attended to start treatment of disease for the first time. All patients included in this study did not receive chemotherapy. Patients were asked to bring their paraffin embedded tissue blocks to participate in estrogen, progesterone and Her-2/nue receptors estimation. Blood samples were also collected from the patients to estimate positive Her-2nue cases in serum. Age distribution in women with breast cancer showed that 44%of cases at age group (40 – 49) years. 23% of the patients had a positive family history (first and second degree). Histological types of breast carcinoma showed that 82%, 14% and 4% were ductal, lobular and mixed carcinoma respectively. The Makee classification showed that Grade I, II, and III were detected in 10%, 64% and 26% respectively. TNM staging revealed that 16% of the patients were recorded in stage I, 44% in stage II, 32% in stage III and 8% in stage IV. It was demonstrated that 72% and 70% of breast carcinomas were positive for ER and PR respectively; both markers correlated with age, family history, type, histological grade and stage of the disease. Her-2/neu showed 28% expression in Iraqi breast cancer cases. HER2/neu over-expression (>15 ng/ml) was observed in 36 out of 150 patients (24%) Her-2/neu serum level at ELISA diagnosis and in 42 out of 150 (28%) at immunohistochemistry method (IHC).There were significant (P <0.001) association between tissue HER-2/neu and serum HER-2 levels. Detection Her-2/neu in serum by ELISA technique could be used as a method for detection with high rate reached to 78% after mastectomy, also it considered as an excellent method for follow up.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
(The trade-off between privatization Options General contracting firms Using the strategic analysis of the external environment
...Show More Authors

Discussed the research variables are important, privatization options and strategic analysis of the external environment, and that the purpose of the research is the trade-off between privatization options and choose the most appropriate alternative in proportion to the external environment, the research aims to determine the privatization the most appropriate option for companies and public contracting, showing the importance of the study provide the privatization of public companies as a strategy can all its way public sector organizations from the transfer of work practices or private sector organizations and mechanisms to it as contributing to improving the level of skills Develop the current and future level of performance,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Application the generalized estimating equation Method (GEE) to estimate of conditional logistic regression model for repeated measurements
...Show More Authors

Conditional logistic regression is often used to study the relationship between event outcomes and specific prognostic factors in order to application of logistic regression and utilizing its predictive capabilities into environmental studies. This research seeks to demonstrate a novel approach of implementing conditional logistic regression in environmental research through inference methods predicated on longitudinal data. Thus, statistical analysis of longitudinal data requires methods that can properly take into account the interdependence within-subjects for the response measurements. If this correlation ignored then inferences such as statistical tests and confidence intervals can be invalid largely.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
Thermal Effects of 940 nm Diode Laser on Dental Socket Blood after Teeth Extraction for Diabetic Patients
...Show More Authors

Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Operational assessment of biological wastewater treatment using advanced return-mass reactors based on principal component cluster analysis
...Show More Authors
Abstract<p>In this study, field results data were conducted, implemented in 64 biofilm reactors to analyses extract organic matter nutrients from wastewater through a laboratory level nutrient removal process, biofilm layer moving process using anaerobic aerobic units. The kinetic layer biofilm reactors were continuously operating in Turbo 4BIO for BOD COD with nitrogen phosphorous. The Barakia plant is designed to serve 200,000 resident works on biological treatment through merge two process (activated sludge process, moving bed bio reactio MBBR) with an average wastewater flow of 50,000 m3/day the data were collected annually from 2017-2020. The water samples were analysis in the central labor</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Nov 02 2017
Journal Name
Iraqi Journal Of Laser
Enhancement the Sensitivity of Humidity Sensor Based on an Agarose Coating Transmission-Type Photonic Crystal Fiber Interferometer
...Show More Authors

Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Temperature effect on optical properties of nickel (ii) phthalocyanine tetrasulfonic acid tetrasodium salt (NiPcTs) organic thin films
...Show More Authors

This study describe the effect of temperature on the optical
properties of nickel(ii) phthalocyanine tetrasulfonic acid tetrasodium
salt (NiPcTs) organic thin films which are prepared by spin coating
on indium tin oxide (ITO-glass). The optical absorption spectra of
these thin films are measured. Present studies reveal that the optical
band gap energies of NiPcTs thin films are dependent on the
annealing temperatures. The optical band gap decreases with increase
in annealing temperature, then increased when the temperature rising
to 473K. To enhance the results of Uv-Vis measurements and get
more accurate values of optical energy gaps; the Photoluminescence
spectra of as-deposited and annealed NiPcTs thin fi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 29 2019
Journal Name
Journal Of The College Of Education For Women
Compared to Estimate the volume of runoff Basins valley Dwiridj my way (SCS-CN), (GIUH) using (GIS)
...Show More Authors

The valley Dwiridj of drainage basins task that lies east of Iraq and thus we have in this study the application of tow models athletes on the three basins of the valley to get Mor e values accurate to Estimate the volume of runoff and peak discharge and time climax and through the use of Technology remote sensing (GIS),has been show through the application of both models, that the maximum value for the amount of Dwiridj valley of (1052/m3/s) According to Equation (SCS-CN) and about (1370.2/m3/s)by approach (GIUH) that difference is the amount of discharge to the Equation (SCS-CN) ar not accurate as(GIUH) approaches Equation ecalling the results of the Field ces Department of damand reservoirs that the volume of runoff to the valley wase

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 03 2023
Journal Name
Journal Of Educational And Psychological Researches
Fitting Scoring Rubrics for Electronic Portfolio to Partial Credit Model According to the Number of Assumed Dimensions
...Show More Authors

Abstract

 

The current research aims to reveal the extent to which all scoring rubrics data for the electronic work file conform to the partial estimation model according to the number of assumed dimensions. The study sample consisted of (356) female students. The study concluded that the list with the one-dimensional assumption is more appropriate than the multi-dimensional assumption, The current research recommends preparing unified correction rules for the different methods of performance evaluation in the basic courses. It also suggests the importance of conducting studies aimed at examining the appropriateness of different evaluation methods for models of response theory to the

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Convergence Analysis for the Homotopy Perturbation Method for a Linear System of Mixed Volterra-Fredholm Integral Equations
...Show More Authors

           In this paper, the homotopy perturbation method (HPM) is presented for treating a linear system of second-kind mixed Volterra-Fredholm integral equations. The method is based on constructing the series whose summation is the solution of the considered system. Convergence of constructed series is discussed and its proof is given; also, the error estimation is obtained. Algorithm is suggested and applied on several examples and the results are computed by using MATLAB (R2015a). To show the accuracy of the results and the effectiveness of the method, the approximate solutions of some examples are compared with the exact solution by computing the absolute errors.

View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Generation of True Random TTL Signals for Quantum Key-Distribution Systems Based on True Random Binary Sequences
...Show More Authors

A true random TTL pulse generator was implemented and investigated for quantum key distribution systems. The random TTL signals are generated by low cost components available in the local markets. The TTL signals are obtained by using true random binary sequences based on registering photon arrival time difference registered in coincidence windows between two single – photon detectors. The true random TTL pulse generator performance was tested by using time to digital converters which gives accurate readings for photon arrival time. The proposed true random pulse TTL generator can be used in any quantum -key distribution system for random operation of the transmitters for these systems

View Publication Preview PDF