Two hundred staphylococcal isolates isolated from milk and white cheese samples, which were collected from local markets in Baghdad. The predominant species was Staphylococcus aureus 97 isolates (48.5%), followed by S.chromogenes 82 (41%) and 21 (10.5%) S.epidermidis isolates. The pattern of antibiotic susceptibility of Coagulase Positive Staphylococci (COPS) and Coagulase Negative Staphylococci (CONS) isolates to 3 antibiotics (Methicillin, Tetracyclin and Vancomycin) was determined using disc diffusion method; the results revealed that 80 S. aureus isolates (82.47%) found to be methicillin resistant (MRSA) while 8 isolates (8.24%) were vancomycin resistant (VRSA) and 18 S. aureus isolates (18.5%) resist tetracycline antibiotic. Sixty four CONS isolates (62.13%) were methicillin resistant, 28 CONS isolates (27.18%) resist tetracycline, and 5 CONS isolates (4.85%) were vancomycin resistant. Suckling mouse bioassay was tested to investigate the staphylococcal enterotoxin biological activity. Results showed that 131 isolates which constitutes 65.5% of the examined isolates, gave a positive result. Both COPS and CONS isolates were shown to be enterotoxigenic, COPS represented by S. aureus species occupied the higher ratio of the enterotoxigenic staphylococci, 86 S.aureus isolates (65.64% of the enterotoxigenic staphylococci) gave the positive ratio of the intestine weight to the body weight which was ≥ 0.083 while 45 CONS isolates (34.35%) were enterotoxin producers. These toxins were thermostable staphylococcal enterotoxins which gave the same toxic effect after heating to 100°C for 30 minutes.
This study aims to identify the role of electronic management in simplifying the work procedures at Imam Muhammad bin Saud Islamic University. The study was based on the random sample of (366) individuals. The data were collected through interviews and questionnaire. The statistical tests were applied according to the data and the study hypotheses: Cronbach’s Alpha, mean, standard deviation, Z test, ANOVA. The study concluded numbers of results: Imam Muhammad bin Saud Islamic University applies electronic management in its administrative processes (planning, organizing, directing, controlling) to a very high level. There are substantial differences in the views of the sample me
... Show MoreAbstract:
The current research aims to demonstrate the relationship of correlation and influence between the independent variable strategic control through its dimensions represented by (organizational structure, human resources management, commitment to specialization, defining powers and responsibilities, values and integrity) and the dependent variable the performance of the insurance company, and the degree of arrangement of these dimensions according to their importance, as well as Detection of significant differences in the sample's response to the questionnaire paragraphs in the researched company, and the research problem
... Show MorePrevious studies indicated that supplementation with antioxidants has a protective effects against oxidative stress–induced damage in type 2 diabetes. In this study we evaluated the antioxidant effects of melatonin on the oxidative stress parameters and microalbuminuria in type 2 DM patients. 30 patients with type 2 DM were treated with 3mg/day melatonin for 90 days. Erythrocytes and plasma MDA and glutathione, fasting plasma glucose, %HbAIC, microalbuminuria, total plasma protein and lipid profile were measured each 30 days and compared with those obtained from 20 healthy controls.
A decrease in MDA levels associated with the elevation in GSH levels were observed, compared with the pre–treatment levels.
... Show MoreBackground:In this study,TiO2 layer was thermally grown as a diffusion barrier on CP Ti substrate prior to electrophoretic deposition of HA coatings, to improve the coating’s compatibility also macro and micro pores in nano Hydroxyapatite dual coatings were created and their effect on the bond strength between the bone and implant was evaluated. Materials and methods: Electrophoretic Deposition technique (EPD) was used to obtain coatings for each one of four types of Hydroxyapatite(HA)on CP Ti screws (micro HA, nano HA, dual nano HA with micro pores, dual nano HA with macro pores) where carbon particles used as fugitive material to be removed by thermal treatment to create porosity.For examination of the changes occurred on the subs
... Show MoreA simple, fast, and sensitive batch and flow injection spectrophotometric
methods have been developed for the determination of clonazepam(CZP) in pure
form and in pharmaceutical preparations. The proposed methods are based on the
oxidative coupling reaction of the reduced clonazepam using Zn powders and conc.
HCl with payrocatechol and in the presence of ferric sulphate. The resulting reddish
colored product had a maximum absorbance at 515 nm. The optimum reaction
conditions and other analytical parameters have been evaluated . The linear ranges
for the batch and FI methods determination of CZP were 0.5-32, 50-400 μg mL-1
and the detection limits were 0.193, 22.60 μg mL-1 for both methods respectively.
Statis
Background: Patient satisfaction is of increasing importance and widely recognized as an important indicator of quality of the medical care. There was no homogeneous definition of patient satisfaction, since satisfaction concerns different aspects of care or settings, as well as care given by various professions.
Objective: The objective of this study is to assess the patients’ level of satisfaction with diabetes care and to identify the underlying factors influencing it.
Methods: This cross-sectional study had been conducted in the Specialized Center for Diabetes and Endocrinology in Baghdad Al- Rusafa 2018. Where150 type two diabetic patients attending their follow-up
... Show MoreHigh-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreThe objective of this study was to determine the concentration of trace element chromium(III) and thyroid peroxidase activity in human serum , and to find a relationship between the concentration of chromium(III) and thyroid peroxidase activity in serum of patients with hypothyroidism, hyperthyroidism and healthy subjects. Serum thyroid peroxidase was measured by enzyme linked radioimmunoassay(ELISA) method and chromium determination was by atomic absorption spectrophotometer .Comparing the values of chromium concentration and thyroid peroxidase activity in both samples showed that there were significant positive correlations between chromium levels and thyroid peroxidase activity(P<0.01, r=0.11).
... Show More